| Plan Review Stops For Permit 19021022 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-21 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-21 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-28 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-28 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2019-02-28 08:20:45 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 19021022 | | | REVIEWED: FEBRUARY 28, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | | | | 1. SHEET A000 BUILDING CODE DATA STATES NUMBER OF EXITS | | | REQUIRED = 2 AND NUMBER PROVIDED = 1. | | | -PLEASE UPDATE IF THIS IS REVERSED. | | | | | | 2. SHEET A000 BUILDING CODE DATA SHOWS OCCUPANY DATA. | | | VERIFY IF THE LINE STOCKROOM SHOULD SAY 15 PEOPLE. I | | | THINK IT GOES IN LINE BELOW TOTAL OCCUPANT LOAD. | | | -ADJUST TOTAL IF NEEDED TO INCLUDE STOCK ROOM TO SALES | | | AREA + TOILET ROOMS LINE. | | | | | | 3. 501 FBC[EXISTING] PROVIDE EXISTING OCCUPANCY. | | | -IF NO CHANGE IN OCCUPANCY, PLEASE STATE OCCUPANCY AS | | | NO CHANGE FROM PREVIOUS. THIS WILL SATISFY THE IMPACT | | | STOP THAT WAS INCLUDED WITH THIS PERMIT REVIEW. | | | | | | NOTES: | | | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-16 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-16 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-28 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-28 |
Time |
06:55 |
Sent To |
|
|
| Notes |
| 2019-02-28 07:34:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLANS NEED APPROVAL FROM PALM BEACH OUTLETS | | | MANAGEMENT PRIOR TO APPROVAL. WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4 | | | 3. IF THERE IS ANY LOAD BEING ADDED, PROVIDE LOAD | | | CALCULATION FOR SERVICE, INCLUDE EXISTING AND NEW LOADS | | | TO CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, | | | 220, 408.30 | | | 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | | INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC | | | 105.1, 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-02-26 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-02-26 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2019-02-26 11:33:46 | PERMIT # 19021022 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | 2) ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A | | | LOCK/UNLOCK INDICATOR. | | | | | | 3) EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED | | | WITH SIGNS OR STENCILING READING FIRE BARRIER-PROTECT | | | ALL OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN | | | HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE | | | SPACED NOT MORE THAN 15 FEET ON CENTER. | | | | | | 4) PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN | | | STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE | | | MAINTAINED AT ALL TIMES. | | | | | | 5) SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO | | | THE FIRE ALARM AND SPRINKLER SYSTEM. | | | | | | 6) WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT | | | SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED | | | AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE | | | MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM | | | SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD | | | INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY | | | BE NEEDED. | | | | | | | | | SUE ELLEN CALDERON | | | ASST. FIRE MARSHAL | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-21 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-11 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-03-05 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-02-22 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-21 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-21 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2019-03-21 15:48:47 | PBC REVIEWED, STAMPED AND NO CHANGE IN USE OR AREA. | | | NO MU NUMBER BECAUSE NO FEES CHARGED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-28 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-28 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2019-02-28 08:21:40 | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-03-19 |
Time |
11:21 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-03-19 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2019-03-19 11:21:46 | THE SIGNS REQUIRE SEPARATE PERMITS WITH PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-03-04 |
Time |
16:31 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-03-04 |
Time |
16:31 |
Sent To |
PC |
|
| Notes |
| 2019-03-04 16:47:12 | FAILED | | | | | | 1) THE LANDLORD APPROVAL STAMP IS NOT PROVIDED ON THE | | | SUBMITTED PLANS. | | | | | | 2) THE SIGNS REQUIRE SEPARATE PERMITS WITH PLANS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|