| Plan Review Stops For Permit 19021006 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-24 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-23 |
Time |
18:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-08 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-08 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-21 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-21 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2019-03-22 15:53:36 | BUILDING REVIEW COMMENTS: | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- LIFE SAFETY PLAN SHEET A008 IS SHOWING EGRESS TRAVEL | | | DISTANCE FROM POINT C TO EXIT #2 PASSING THRU THE WORK | | | AREA ROOM. LIFE SAFETY PLAN AND ELECTRICAL PLAN ARE | | | MISSING THE EXIT SIGNS SHOWING THE EGRESS PATH AT THIS | | | AREA. SEC. 1013.1 FBC. SHOW THE REQUIRED EXIT SIGNS. | | | | | | 2- DOOR #13 IN THE BREAK ROOM AREA DOESN'T COMPLY WITH | | | THE DOOR MANEUVERING CLEARANCE REQUIRED BY SEC. 404.2.4 | | | FBC-ACCESSIBILITY ON THE PULL SIDE. REVISE AS REQUIRED. | | | | | | 3- CHECK-IN COUNTER NEEDS TO COMPLY EITHER WITH SEC. | | | 904.4.1 FBC-ACCESSIBILITY FOR PARALLEL APPROACH OR SEC. | | | 904.4.2 FBC-ACCESSIBILITY FOR FORWARD APPROACH. REVISE | | | PLANS AND DETAIL 1/A503 AS REQUIRED. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-05-01 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-05-01 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-03-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-12 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-03-12 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-05-01 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-05-01 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-04-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-04-29 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-03-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-04 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-06-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-15 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-14 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-19 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-16 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-25 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-24 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-15 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2019-05-24 06:27:17 | 5/24 PLAN STAMPED, NO FEE DUE PER EMAIL FROM W.SWOOPE | | | MU-2019-015105-0000 | | | | | | | | 2019-05-15 08:21:54 | 5/15/19 SENT EMAIL TO IMPACT FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-16 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-16 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2019-04-16 17:22:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-06-03 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-06-03 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-01 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-01 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2019-05-01 10:46:38 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19021006 | | | 5/1/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) COMMENT #1 FROM THE 1ST REVIEW WAS NOT COMPLETELY | | | ADDRESSED- SEE BELOW AND COMPLY. | | | | | | 1) SHEETS M0003 & M101: PROVIDE EXHAUST VENTILATION | | | CALCULATIONS FOR EF-1, EF-2, EF-3, & EF-6, AND A | | | SEQUENCE OF OPERATION FOR EACH FAN- TABLE 403.3.1.1 FBC | | | M. A) INDICATE HOW MAKEUP AIR IS BEING PROVIDED FOR | | | EACH SYSTEM. | | | | | | 2) M101, MED GAS STORAGE EXHAUST: A) THE FIRE DAMPER IS | | | PROHIBITED IN THE HAZARDOUS EXHAUST SYSTEM- SECTION | | | 510.7.1 FBC M. B) THE EXHAUST DUCT SHALL BE ENCLOSED IN | | | 1-HR FIRE-RESISTANT RATED CONSTRUCTED FROM THE POINT OF | | | PENETRATION OF THE FIRE-RATED WALL TO THE OUTLET | | | TERMINAL- SECTION 510.7.3 FBC M. C) THE EXHAUST DUCT | | | SHALL BE CONSTRUCTED OF G90 GALVANIZED STEEL OR | | | NON-METALLIC MATERIALS THAT EXHIBIT A FLAME SPREAD | | | INDEX OF 25 AND A SMOKE-DEVELOPED INDEX OF 50 OR LESS | | | SECTION 510.9 FBC M. D) MAKEUP AIR SHALL BE PROVIDED AT | | | A RATE APPROXIMATELY EQUAL TO THE RATE THAT AIR IS | | | BEING EXHAUSTED BY THE SYSTEM- SECTION 510.6.5 FBC M. | | | E) PROVIDE THE SEQUENCE OF OPERATION FOR EF-3- SEE | | | COMMENT #1 ABOVE. | | | | | | 3) M002: INCOMPLETE DETAILS HAVE BEEN PROVIDED FOR | | | MOUNTING THE EF-3 ROOF FAN AND CURB, AND NO DETAILS | | | HAVE BEEN PROVIDED FOR RH-1- SEE SECTION 301.15 FBC M | | | AND COMPLY. PROVIDE THE WIND LOAD DESIGN CRITERIA FOR | | | THE INSTALLATIONS, COMPLETE MOUNTING AND ANCHORING | | | DETAILS, AND SUBMIT FL. PRODUCT APPROVALS AND/OR | | | MIAMI-DADE NOA'S FOR THE UNITS-= RULE 9N-3 FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-26 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-26 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2019-03-26 16:24:39 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19021006 | | | 3/26/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS M0003 & M101: PROVIDE EXHAUST VENTILATION | | | CALCULATIONS FOR EF-1, EF-2, EF-3, & EF-6, AND A | | | SEQUENCE OF OPERATION FOR EACH FAN- TABLE 403.3.1.1 FBC | | | M. A) INDICATE HOW MAKEUP AIR IS BEING PROVIDED FOR | | | EACH SYSTEM AND PROVIDE AIR BALANCE CALCULATIONS- | | | SECTION 501.4 FBC M. | | | | | | 2) M101: AUTOMATIC SHUTOFF DAMPERS, EITHER MOTORIZED OR | | | GRAVITY, SHALL BE PROVIDED FOR THE O/A SUPPLY DUCTS TO | | | THE HP'S- SECTION C403.2.4.3 FBC-17 EC | | | | | | 3) M101: INDICATE THE TOTAL NUMBER OF CYINDERS AND | | | TOTAL CU.FT. OF OXYGEN AND NITROUS OXIDE GAS TO BE | | | STORED IN THE MED GAS CLOSET SECTION 307.1 FBC B. A) | | | INDICATE HOW THE CYLINDERS WILL BE SECURED IN THE | | | CLOSET. | | | | | | 4) M101: NOTE 1 INDICATES CONDENSATE TO BE DRAINED INTO | | | THE CITY SANITARY WHICH IS PROHIBITED PER SECTION | | | 90-126 WPB CODE OF ORDINANCES. PLEASE PROVIDE A | | | COMPLETE CONDENSATE DISPOSAL PLAN FOR ALL OF THE | | | HANDLERS- SECTION 307.2.1 FBC M. | | | | | | 5) M002: PROVIDE COMPLETE ANCHORING AND MOUNTING | | | DETAILS FOR THE FANS AND FAN CURBS- SECTION 301.15 FBC | | | M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
2 |
Status |
P |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-25 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-25 |
Time |
17:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
F |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-03-28 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-03-28 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2019-03-28 07:59:26 | 1ST REVIEW: 19021006 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | MED GAS COMMENTS: | | | | | | 1. PROVIDE ROOF DRAWING SHOWING DISTANCE FROM VACUUM | | | EXHAUST TO AIR INTAKES. PER NFPA 99 | | | 2. PLEASE STATE ON PLAN WHAT CATEGORY THE MED GAS | | | SYSTEM IN BEING DESIGNED FOR. PER NFPA 99 | | | 3. PROVIDE NOTE ON THE PLAN THE CONTRACTOR AND | | | INSTALLER SHALL BE MED GAS CERTIFIED AND SHALL PROVIDE | | | CERTIFICATION FOR PERMIT ISSUANCE AND INSPECTIONS. PER | | | FAC 61G4-15.031(1)(4A)(4B) | | | 4. PROVIDE ISOMETRIC DRAWING FOR MED GAS INCLUDING | | | VACUUM EXHAUST. WPB AMEND TO FBC 107.3.5.1.3(13) | | | 5. PROVIDE PIPING DETAIL OF CONTROL VALVES AND TANK | | | MANIFOLD ALSO DETAIL OF HOW TANK ARE SECURED. PER WPB | | | AMEND TO FBC 107.2.1 AND NFPA 99 | | | 6. NOTE ON THE PLAN THE NUMBER AND SIZE OF TANKS. PER | | | WPB AMEND TO FBC 107.2.1 AND NFPA 99 | | | 7. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDES FOR ALL MED GAS EQUIPMENT. PER WPB AMEND TO FBC | | | 107.2.1 AND NFPA 99 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-25 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-25 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-03-28 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-03-25 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2019-03-28 07:26:26 | 1ST REVIEW: 19021006 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1.PROVIDE DETAIL SHOWING MOUNTING HEIGHTS OF THE GRAB | | | BARS 33" MIN TO 36" TO THE TOP OF THE GRIPPING SURFACE. | | | PER FBC ACC 609.4 | | | 2.PROVIDE ISOMETRIC DRAWING FOR WATER INCLUDING VALVES | | | ON DROPS DIRECTION OF FLOW AND LABEL HOT COLD AND | | | RETURN. PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | 3. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-05-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-23 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-23 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-14 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-14 |
Time |
17:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-16 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-16 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2019-04-16 17:24:46 | DIGITAL SIGNATURES ARE OK - NEW PAGES SUBMITTED NEXT | | | REVIEW CYCLE REQUIRE VERIFICATION | | | | | | S.HILL, 561-805-6724 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-05-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2019-05-01 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2019-05-01 10:05:23 | LANDSCAPE PERMIT REQUIRED | | | | | | PAUL GREILICH, SENIOR PLANNER | | | [email protected] | | | 561-822-1443 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
pgreilic |
Date |
2019-04-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2019-04-16 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2019-04-16 16:38:24 | PROVIDE SITE PLAN OR SURVEY INDICATING LIMITS OF WORK | | | AND NOTE THAT WORK WILL BE LIMITED TO EXISTING BUILDING | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|