Plan Review Details - Permit 19020956
Plan Review Stops For Permit 19020956
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2019-07-24 Cont ID  
Sent By shill Date 2019-07-24 Time 11:13 Rev Time 0.00
Received By shill Date 2019-07-24 Time 11:13 Sent To  
Notes
2019-07-24 11:14:37AIPP OK PER EMAIL FROM S.WELTER DATED 6/27/19
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-28 Cont ID  
Sent By pvalenti Date 2019-05-28 Time 17:04 Rev Time 0.00
Received By pvalenti Date 2019-05-22 Time 07:45 Sent To  
Notes
2019-05-28 17:24:42PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 2ND BUILDING PLAN REVIEW
  
 APPROVED WITH PROVISOS:
  
 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY,
 THE REQUIREMENTS OF ART IN PUBLIC PLACES WILL NEED TO
 BE COMPLIED WITH.
 2. THE DEFERRED SUBMITTALS, AS NOTED ON PAGE S-1.0,
 WILL NEED TO BE SUBMITTED TO THE CITY AFTER MASTER
 PERMIT HAS BEEN ISSUED.
 3. THE DELEGATED ENGINEERED DOCUMENTS WILL NEED TO BE
 FORWARDED TO THE ENGINEER OF RECORD FOR REVIEW AFTER
 THE MASTER PERMIT HAS BEEN ISSUED.
 4. AT TIME OF INSPECTION PROVIDE WELD PROCEDURE
 SPECIFICATIONS AND WELDER QUALIFICATION RECORDS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-04-01 Cont ID  
Sent By jwitmer Date 2019-04-01 Time 13:08 Rev Time 0.00
Received By jwitmer Date 2019-04-01 Time 07:15 Sent To  
Notes
2019-04-01 13:08:202017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19020956
 ADD: 4257 UP THE GROVE LANE
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-694-3828
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. APRIL 1ST/ 2019
 ACTION: DENIED
  
 1) ART IN PUBLIC PLACES.
 THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES
 ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR
 NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT
 APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL
 PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 SEC. 78-129. - PUBLIC ART ASSESSMENT FOR PRIVATE
 DEVELOPMENT.
 (A) APPLICABILITY. THE PROVISIONS OF THIS ARTICLE AND
 THE PUBLIC ART ASSESSMENT SECTION SHALL APPLY TO ALL
 PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000.00. ALL BUILDINGS
 WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED
 CUMULATIVELY TOWARDS THIS ART IN PUBLIC PLACES
 REQUIREMENT, EVEN IF THE BUILDINGS ARE PERMITTED
 SEPARATELY OR DEVELOPED IN PHASES. THE PROVISIONS OF
 THIS SECTION APPLY TO NEW DEVELOPMENT OR NEW
 CONSTRUCTION WITHIN EXISTING PLANNED DEVELOPMENTS.
  
  
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 2) IN THE SUPPORTING DOCUMENT FILE THE REPORT
 COMPUTATIONS FOR FPL WEST PALM BEACH COMMISSARY
 BUILDING DO NOT HAVE AN ELECTRONIC SEAL.
  
 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS,
 REPORTS OR OTHER DOCUMENTS.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 3) SHEET 040_S-1.0 THE GENERAL NOTES- FOUNDATIONS
 INDICATES THAT A SOILS REPORT HAS BEEN PREPARED.
 SOILS REPORT BY INTERTEK OF 08-24-2018. PLEASE SUBMIT
 EITHER A REPORT WITH ELECTRONIC SIGNATURE OR PAPER
 ORIGINAL WITH ORIGINAL SEAL, SIGNATURE AND DATE.
 2017 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE
 CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL
 IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO
 THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING
 OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A
 GEOTECHNICAL INVESTIGATION BE CONDUCTED.
  
 4) THE PLANS INDICATE THIS PROPOSED BUILDING WILL HAVE
 TILT-WALL CONSTRUCTION. THIS BUILDING WILL REQUIRE A
 RESIDENT INSPECTOR IN ACCORDANCE WITH SECTION 110.3.9
 OF THE WEST PALM BEACH ADMINISTRATIVE CODE. THE
 BUILDING OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY
 OTHERS, THE INSPECTIONS REQUIRED BY SECTION 109. HE/SHE
 MAY ACCEPT REPORTS OF INSPECTORS OF RECOGNIZED
 INSPECTION SERVICES, PROVIDED THAT AFTER INVESTIGATION
 HE/SHE IS SATISFIED AS TO THEIR QUALIFICATIONS AND
 RELIABILITY. A CERTIFICATE CALLED FOR BY ANY PROVISION
 OF THE TECHNICAL CODES SHALL NOT BE BASED ON SUCH
 REPORTS UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY
 A RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING
 OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION
 SERVICE IN THE FOLLOWING INSTANCES:
 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE
 STRENGTH (F ?C) IN EXCESS OF 3000
 POUNDS PER SQUARE INCH
 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR
 METHODS OF CONSTRUCTION (TILT-WALL BUILDINGS)
  
 RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL PARTIES
 NOTARIZED AND RETURNED TO THE BUILDING DEPARTMENT.
 FORMS SENT TO: [email protected] TIME: 10:37 AM MON.
 APRIL 01/ 2019
  
 5A) SHEET 040_S-1.0 UNDER THE HEADING OF DEFERRED
 SUBMITTALS INDICATES THE CONCRETE TILT PANEL ERECTION
 IS TO BE DEFERRED. THE RESIDENT INSPECTOR WILL HAVE TO
 HAVE THE INFORMATION LISTED UNDER TILT-UP PANELS,
 PANEL MINIMUM MODULES OF RUPTURE AND COMPRESSIVE
 STRENGTH AS REQUIRED BY THE LIFTING ENGINEER, LIFTING
 INSERTS AND ADDITIONAL REINFORCING STEEL, CHAIRS & OR
 BOLSTERS AS REQUIRED BY THE SPECIALTY ENGINEER,
 LOCATION OF THE REINFORCEMENT FOR THE TILT WALL PANEL,
 ALL EMBEDS (I.E. PLATES, ANGLES, ETC.) LOCATION OF ALL
 OPENINGS AND THE CORRESPONDING DIMENSIONS, MISC.
 OPENINGS FOR REQUIRED, FIRE LINES, PLUMBING, ELECTRICAL
 LINES BEFORE THE CONCRETE PANELS CAN BE POURED.
  
 5B) 61G15-30.003 ENGINEERING DOCUMENT CLASSIFICATION.
 FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL
 FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE
 ENGINEER OF RECORD FOR REVIEW.
  
 5C) THE RESIDENT INSPECTOR WILL BE REQUIRED TO OVERSEE
 ALL STRUCTURAL INSPECTIONS AS REQUIRED IN THE CITY
 ADMINISTRATIVE CODE 100.3 FOUNDATION THROUGH THE
 ANCHORING OF THE ROOF DECK WITH EXCEPTION OF COMPONENTS
 AND CLADDING OF WINDOWS, DOORS AND ROOFING, THESE WILL
 BE COMPLETED BY THE CITY BUILDING INSPECTORS. IF THERE
 IS ANY QUESTIONS AS TO WHAT THE RESIDENT INSPECTOR WILL
 NEED TO VERIFY AS TO STRUCTURAL INSPECTIONS PLEASE
 CONTACT KEN CONRAD ADMINISTRATOR OF THE RESIDENT AND
 SPECIAL INSPECTOR PROGRAM AT:
 KEN CONRAD
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 6) THE STRUCTURAL SHEETS HAVE THE ELECTRONIC SIGNATURES
 100% COMPLETE, WE ARE GETTING THE NOTE,
 THE SIGNER?S IDENTITY IS UNKNOWN BECAUSE IT HAS NOT
 BEEN INCLUDED IN YOUR LIST OF TRUSTED CERTIFICATES AND
 NONE OF ITS PARENT CERTIFICATES ARE TRUSTED
 CERTIFICATES. THE ARCHITECTURAL SHEETS OK. 61G15-23.005
 PROCEDURES FOR SIGNING AND SEALING ELECTRONICALLY
 TRANSMITTED PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS.
  
 7) SHEET 038_A-5 WINDOW SECTION 4 SHOWS 1 INCH WOOD
 WINDOW BUCKS. THE PLAN INDICATES THE USE OF MASONRY
 ANCHORS. NONE OF THE ARCHITECTURAL NOR STRUCTURAL
 SHEETS SHOW ANY MORE DETAIL OF THE TYPES OF ANCHORS TO
 BE INSTALLED, SIZE AND DIAMETER OR SPACING OF THE
 ANCHORS FROM THE BUCKS TO THE CONCRETE TILT WALL. THE
 ANCHORING OF WOOD BUCKS IS NORMALLY THE STRUCTURAL
 ENGINEERS? RESPONSIBILITY AND NOT FOUND IN THE PRODUCT
 APPROVALS.
 2017 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND DOORS
 SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND SPACING
 SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
  
 8) SHEET 029_A-3.3 RESTROOM ELEVATIONS DETAIL THE HC
 SINK SHOWS THE 40 INCH MEASUREMENT OF 40 INCHES FROM
 THE FINISH FLOOR TO THE BOTTOM OF THE MIRROR. PLEASE
 REVIEW THE 2017 FBC-ACCESS. CODE SECTION
 603.3 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES OR
 COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF
 THE REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED
 ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH
 THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES
 (890 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 9) SHEET 030_A3.4 THE SECTION OF THE LAUNDRY ROOM SINK
 SHOWS THE ELEVATION OF 2 FOOT 10 INCHES TO THE TOP OF
 THE COUNTERTOP BUT NOT THE TOP OF THE SINK, THE
 THICKNESS OF THE SINK RIM MAY OR MAY NOT BE IN THE
 CONSTRUCTION TOLERANCES THIS WOULD BE SOMETHING THE
 PLUMBING INSPECTOR AND OR PLUMBING REVIEWER MAY NEED TO
 ADDRESS.
  
 DISCREPANCY IN PLANS, SHEET 036_A-4.2 DETAIL J SHOWS
 THE ROOF AS SBS HEAT WELDED MODIFIED BITUMINOUS
 MEMBRANE ROOFING W/ CAP SHEET OVER GYPSUM FIBER BOARD
 AND POLYSOCYANURATE ROOF INSULATION AND B DECK WHEREAS
 THE STRUCTURAL SHEET 043_S3.1 DETAIL B SHOWS A 4 INCH
 CONCRETE SLAB ON B DECK. PLEASE ALSO REFER BACK TO THE
 INPUT DATA REPORT WHICH ALSO HAS DIFFERENT MATERIALS
 AND THICKNESS. 107.2.1.2 ADDITIONAL INFORMATION IS
 REQUIRED.
  
 10) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS.
 (C) PANEL WALLS: WALL LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION ROOFING MATERIALS,
  
 11A) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE
 CODE RULE 61G20 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 11B) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 11C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 12) IDENTIFY GLAZING. PLEASE IDENTIFY ON THE PRODUCT
 APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND
 BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL
 PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING
 WIDTH & HEIGHT, TYPE OF GLAZING, MULLION SIZE, LENGTH
 IF UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
 ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
 SIZE. 2017 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
 DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND SPACING
 SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
  
 13) EFIS SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL
 FOR THE SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE
 MANUFACTURERS INSTALLATION BROCHURE PROVIDING
 COMPLIANCE WITH 2014 FBC-B SECTIONS;
 1408.2 PERFORMANCE CHARACTERISTICS.
 1408.2 PERFORMANCE CHARACTERISTICS.
 1408.3 STRUCTURAL DESIGN.
 1408.4 WEATHER RESISTANCE.
 1408.4.1 EIFS WITH DRAINAGE.
 408.4.1.1 WATER-RESISTIVE BARRIER.
 1408.5 INSTALLATION
  
 14) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF
 ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR
 BOTH INSULATION & THE BASE SHEET AS CALCULATED IN
 COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117.
 CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 15) IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
 16) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER19030471
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-05-24 Cont ID  
Sent By jpearson Date 2019-05-24 Time 15:13 Rev Time 0.00
Received By jpearson Date 2019-05-24 Time 15:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-03-25 Cont ID  
Sent By jpearson Date 2019-03-25 Time 13:10 Rev Time 0.00
Received By jpearson Date 2019-03-21 Time 12:16 Sent To  
Notes
2019-03-25 13:10:53CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND
 SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN
 THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC
 105.1, 107.2.1
 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2019-05-22 Cont ID  
Sent By rrossano Date 2019-05-22 Time   Rev Time 0.00
Received By rrossano Date 2019-05-22 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-03-22 Cont ID  
Sent By shill Date 2019-03-22 Time 16:15 Rev Time 0.00
Received By shill Date 2019-03-22 Time 16:15 Sent To  
Notes
2019-03-22 16:16:05CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-05-01 Cont ID  
Sent By pleduc Date 2019-05-01 Time   Rev Time 0.00
Received By pleduc Date 2019-05-01 Time 13:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-03-05 Cont ID  
Sent By pleduc Date 2019-03-05 Time   Rev Time 0.00
Received By pleduc Date 2019-03-05 Time 09:18 Sent To  
Notes
2019-03-05 09:25:26THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) FIRE LINE UNDERGROUND IS INDICATED. ALL FIRE LINE
 UNDEERGROUND SHALL BE UNDER SEPARATE SHOP DRAWINGS AND
 PERMIT.
  
 ALL FIRE LINE UNDERGROUND SHALL COMPLY WITH NFPA 24.
  
  
  
 2) THE HOOD AND SUPPRESSION SYSTEMS SHALL BE UNDER
 SEPARATE SHOP DRAWINGS AND PERMITS.
  
  
  
  
 3) THERE IS AN INDICATION OF AN EMERGENCY GENERATOR.
 THE GENERATOR SHALL BE INSTALLED UNDER SEPARATE SHOP
 DRAWINGS AND PERMIT.
  
 THE GENERATOR INSTALLATION SHALL COMPLY WITH NFPA 37,
 2015 ED AND 110, 2013 ED.
  
  
  
  
 4) THERE IS AN INDICATION OF NFPA 101, 2018 ED. FOR
 INFORMATIONAL PURPOSES THE CURRENT EDITION OF NFPA 101
 IS 2015.
  
 THE CURRENT EDITION OF THE FFPC WAS ADOPED ON DEC. 31,
 2018, WHICH INCLUDED NFPA 1, 2015 ED AND 101, 2015 ED
 WITH FL ADMENDMENTS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-05-15 Cont ID  
Sent By gjohnson Date 2019-05-15 Time 16:09 Rev Time 0.00
Received By gjohnson Date 2019-05-15 Time 16:09 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-04-02 Cont ID  
Sent By jesmith Date 2019-04-02 Time 14:10 Rev Time 0.00
Received By jesmith Date 2019-04-02 Time 14:08 Sent To  
Notes
2019-04-02 14:09:29CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 NFPA 96
  
 1ST REVIEW
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS
  
 GAS COMMENTS: DENIED
 1. SYSTEM SIZED PER FBC FG TABLE 402.4(2). TOTAL LENGTH
 IS 101?. BASED UPON 125? IN THE TABLE, ITEMS C, D AND F
 ARE UNDERSIZED. CORRECT AS REQUIRED BY THE TABLE PER
 WPB FBC 107.2.1
 2. 34? INCREMENT UPSTREAM OF 1ST BRANCH IS SIZED
 2-1/2?. CORRECT SIZE TO COMPLY WITH FBC FG TABLE
 402.4(2) BASED ON 125?.
 3. 5? INCREMENT BETWEEN ITEMS G AND G IS UNDERSIZED.
 CORRECT SIZE TO COMPLY WITH FBC FG TABLE 402.4(2) BASED
 ON 125?.
 4. BRANCH TO WATER HEATERS IS UNDERSIZED. CORRECT SIZE
 TO COMPLY WITH FBC FG TABLE 402.4(2) BASED ON 125?.
 INDIVIDUAL SUPPLY LINE TO EACH OF THE HEATERS IS
 UNDERSIZED. CORRECT SIZES TO COMPLY WITH FBC FG TABLE
 402.4(2) BASED ON 125?.
 5. PER WPB FBC 107.2.1, PROVIDE CUT LENGTHS FOR THE
 HORIZONTAL EAST-WEST INCREMENTS BETWEEN THE WATER
 HEATERS AND THE HORIZONTAL NORTH-SOUTH INCREMENTS TO
 THE VERTICAL DROPS.
 6. PER WPB FBC 107.2.1, SPEC MANUFACTURER MODEL NUMBER
 OF AUTOMATIC GAS SHUT OFF VALVE; PROVIDE WITH MANUAL
 RESET PER NFPA 96 CHAPTER 10.
 7. PER WPB FBC 107.2.1, PROVIDE DETAILS FOR THE
 FOLLOWING SHOWING VALVES, DIRT LEGS, UNIONS AND OTHER
 REQUIRED APPURTENANCES AS REQUIRED BY FBC FG AND NFPA
 96, THE FOLLOWING.
 A. TYPICAL CONNECTION TO COOKING APPLIANCE
 B. CONNECTION TO PUBLIC METER/REGULATOR
 C. EMERGENCY SHUTOFF FOR KITCHEN EQUIPMENT
 8. WILL ALL PIPING BE THREADED, OR WILL SOME BE WELDED?
 PER WPB FBC 107.2.1, PLEASE CLARIFY AND PROVIDE
 SPECIFICATIONS FOR PIPE, VALVES AND FITTINGS.IF WELDING
 IS TO BE REQUIRED, PROVIDE REQUIRED PROCEDURES.
 9. GAS RISER DIAGRAM ON P3.1 INDICATES THREE (3) GAS
 WATER HEATERS. DETAIL ON P5.0 AND PLUMBING FIXTURE
 SCHEDULE ON P4.0 INDICATE TWO (2) GAS WATER HEATERS AND
 ONE (1) ELECTRIC WATER HEATER. PLEASE CLARIFY PER WPB
 FBC 107.2.1.
 10. SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR THE
 COOKING LINE APPLIANCES PER FBC FG 304.1.
 11. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT (KITCHEN
 EQUIPMENT AND WATER HEATERS) TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND FBC FG 402.2. GAS
 APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION.
 12. PER WPB FBC 107.2.1, SUBMIT A DETAIL SHOWING THE
 TYPE, LOCATION, ELEVATIONS, SIZE, AND TERMINATION
 POINTS OF GAS WATER HEATER DIRECT VENT COMBUSTION AIR
 AND VENT.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN
 ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED "VOID".
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19020956 4257 UP THE GROVE LN
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2019-06-03 Time   Rev Time 0.00
Received By lmarchan Date 2019-05-31 Time 14:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-05-30 Time   Rev Time 0.00
Received By lmarchan Date 2019-04-30 Time 13:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-18 Cont ID  
Sent By shill Date 2019-04-15 Time 06:13 Rev Time 0.00
Received By shill Date 2019-02-22 Time 16:18 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-06-07 Cont ID  
Sent By lmarchan Date 2019-06-07 Time 10:41 Rev Time 0.00
Received By lmarchan Date 2019-05-31 Time 14:52 Sent To  
Notes
2019-06-07 10:43:12RECEIPT 2019-0607-252 - $21,583.53 PAID
2019-05-31 14:53:005/31/19 SENT TO IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-04-01 Cont ID  
Sent By jwitmer Date 2019-04-01 Time 13:09 Rev Time  
Received By jwitmer Date 2019-04-01 Time 07:15 Sent To  
Notes
2019-04-01 13:09:04) IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-06-03 Cont ID  
Sent By ccole Date 2019-06-03 Time 12:27 Rev Time 0.00
Received By ccole Date 2019-06-03 Time 12:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-05-30 Cont ID  
Sent By ccole Date 2019-05-30 Time 15:13 Rev Time 0.00
Received By ccole Date 2019-05-30 Time 12:51 Sent To  
Notes
2019-05-30 15:15:291ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19020956
 4/9/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BACH AMENDMENTS TO THE FBC SIXTH EDITION
 2017
  
 PLAN REVIEW RESULTS: DENIED.
 PLEASE REVIEW THE COMMENTS LISTED BELOW AND RESUBMIT
 CORRECTED PLANS
  
 1) IN RESPONSE TO THE 1ST REVIEW COMMENT #2 PRINTED
 BELOW, THE ENGINEER OF RECORD JOHN E. HENZP.E. STATES
 IN THE NARRATIVE THAT A NEW M-1.3 PLAN SHEET HAS BEEN
 UPLOADED, HOWEVER THE SHEET WAS NOT UPLOADED FOR
 REVIEW. PLEASE PROVIDE THE SHEET- SECTION 107.2.1 WPB.
  
 2) PROVIDE A KITCHEN EQUIPMENT PLAN AND EQUIPMENT
 SCHEDULE- SECTION 107.2.1 WPB.
  
 3) THE NEW COMMISSIONING PLAN REQUIRES THE ELECTRONIC
 SIGNATURE AND SEAL OF THE ENGINEER WHO PREPARED IT-
 SECTION 61G15-23.002 FAC
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-04-09 Cont ID  
Sent By ccole Date 2019-04-09 Time 10:49 Rev Time 0.00
Received By ccole Date 2019-04-09 Time 07:40 Sent To  
Notes
2019-04-09 10:51:191ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19020956
 4/9/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BACH AMENDMENTS TO THE FBC SIXTH EDITION
 2017
  
 PLAN REVIEW RESULTS: DENIED.
 PLEASE REVIEW THE COMMENTS LISTED BELOW AND RESUBMIT
 CORRECTED PLANS
  
 1) PLEASE NOTE THAT SEPARATE PERMITS ARE REQUIRED FOR
 THE KITCHEN EXHAUST HOODS, FIRE SUPPRESSION SYSTEMS,
 AND THE WALK-IN FREEZERS- SECTION 107.2.1 WPB.
  
 2) PROVIDE A KITCHEN EQUIPMENT PLAN AND EQUIPMENT
 SCHEDULE- SECTION 107.2.1 WPB.
  
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL
 GAS-FIRED COOKING APPLIANCES AND THE GAS WATER HEATERS-
 SECTIONS 623.1 & 624.1 FBC FG.
  
 4) SHEET M2.0: PROVIDE COMBUSTION AIR CALCULATIONS FOR
 THE COOKING APPLIANCES- SECTION 304.1 FBC FG.
  
 5) M1.1: THE COMBUSTION AIR INTAKES FOR THE GAS WATER
 HEATERS APPEAR TO BE IN PROXIMITY OF THE EXHAUST OUTLET
 FOR KEF-1. PLEASE PROVIDE CLEARANCE DISTANCE
 MEASUREMENTS PER THE MANUFACTURER'S INSTALLATION
 GUIDELINES- SECTION 303.1 FBC FG.
  
 6) M2.0: PROVIDE EXHAUST VENTILATION CALCULATIONS FOR
 THE CHEMICAL AND CLEANING STORAGE, TRASH, LAUNDRY, AND
 LOCKER ROOMS- TABLE 403.3.1.1 FBC M. PROVIDE A SEQUENCE
 OF OPERATION FOR THE FANS- SECTION 501.4 FBC M.
  
 7) M1.1: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 DRYER, AND PROVIDE A DRYER EXHAUST DIAGRAM SHOWING THE
 TOTAL RUN LENGTH OF THE DUCT FROM THE DRYER OUTLET TO
 THE TERMINATION LOCATION- SECTIONS 504.1 AND 504.8.4
 FBC M. PLEASE NOTE THAT MAKEUP AIR IS REQUIRED FOR
 DRYERS EXHAUSTING MORE THAN 200 CFMS- SECTION 504.6 FBC
 M
  
 8) M1.1: PROVIDE DUCT SMOKE DETECTORS IN THE SUPPLY
 SYSTEMS OF AHU-1 & 2- SECTION 606.2.1 FBC M.
  
 9) M1.1: ALTHOUGH KEF-1 & 2 ARE UNDER SEPARATE PERMIT,
 PLEASE VERIFY EXHAUST OUTLET CLEARANCE DISTANCES IN
 ACCORDANCE WITH SECTIONS 506.3.13.2 & 506.3.13.3 FBC M
 LISTED BELOW.
  
 506.3.13.2 TERMINATION THROUGH AN EXTERIOR WALL.
 EXHAUST OUTLETS SHALL BE PERMITTED TO TERMINATE THROUGH
 EXTERIOR WALLS WHERE THE SMOKE, GREASE, GASES, VAPORS
 AND ODORS IN THE DISCHARGE FROM SUCH TERMINATIONS DO
 NOT CREATE A PUBLIC NUISANCE OR A FIRE HAZARD. SUCH
 TERMINATIONS SHALL NOT BE LOCATED WHERE PROTECTED
 OPENINGS ARE REQUIRED BY THE FLORIDA BUILDING CODE,
 BUILDING. OTHER EXTERIOR OPENINGS SHALL NOT BE LOCATED
 WITHIN 3 FEET (914 MM) OF SUCH TERMINATIONS.
  
 506.3.13.3 TERMINATION LOCATION.
 EXHAUST OUTLETS SHALL BE LOCATED NOT LESS THAN 10 FEET
 (3048 MM) HORIZONTALLY FROM PARTS OF THE SAME OR
 CONTIGUOUS BUILDINGS, ADJACENT BUILDINGS AND ADJACENT
 PROPERTY LINES AND SHALL BE LOCATED NOT LESS THAN 10
 FEET (3048 MM) ABOVE THE ADJOINING GRADE LEVEL. EXHAUST
 OUTLETS SHALL BE LOCATED NOT LESS THAN 10 FEET (3048
 MM) HORIZONTALLY FROM OR NOT LESS THAN 3 FEET (914 MM)
 ABOVE AIR INTAKE OPENINGS INTO ANY BUILDING.
  
 10) COMMISSIONING OF THE MECHANICAL SYSTEMS ARE
 REQUIRED IN ACCORDANCE WITH SECTION C408.2 FBC EC.
 MECHANICAL SYSTEMS AND SERVICE WATER-HEATING SYSTEMS
 COMMISSIONING AND COMPLETION REQUIREMENTS.
 PRIOR TO THE FINAL MECHANICAL AND PLUMBING INSPECTIONS,
 THE LICENSED DESIGN PROFESSIONAL, ELECTRICAL ENGINEER,
 MECHANICAL ENGINEER OR APPROVED AGENCY SHALL PROVIDE
 EVIDENCE OF MECHANICAL SYSTEMS COMMISSIONING AND
 COMPLETION IN ACCORDANCE WITH THE PROVISIONS OF THIS
 SECTION.
 REFER TO SECTION C408.2.1 AND PROVIDE A COMMISSIONING
 PLAN.
  
 11) GENERATOR: A) SUBMIT MANUFACTURER'S SPECIFICATIONS
 AND THE UL CERTIFICATE OF COMPLIANCE- SECTION 915.1 FBC
 M. B) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 EXHAUST PIPE AND PROVIDE A DIAGRAM SHOWING THE PIPE RUN
 FROM THE GENERATOR TO TERMINATION LOCATION ABOVE THE
 ROOF. C) PROVIDE ENGINEERED DETAILS SHOWING HOW THE
 PIPE WILL BE SUPPORTED AND ATTACHED TO THE BUILDING-
 SECTION 301.15 FBC M. D) PROVIDE BACKPRESSURE
 CALCULATIONS- SECTION 304.1 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-05-15 Cont ID  
Sent By gjohnson Date 2019-05-15 Time 14:26 Rev Time 0.00
Received By gjohnson Date 2019-05-15 Time 12:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-04 Cont ID  
Sent By jesmith Date 2019-04-04 Time 14:56 Rev Time 0.00
Received By jesmith Date 2019-04-02 Time 14:11 Sent To  
Notes
2019-04-04 14:55:56CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL
 MANUAL
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 DERM=PALM BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL
 RESOURCES MANAGEMENT
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 DERM=PBC DEPARTMENT OF ENVIRONMENTAL RESOURCES
 MANAGEMENT
  
 1ST REVIEW PLUMBING
 A SEPARATE PERMIT IS REQUIRED FOR IRRIGATION
 A SEPARATE PERMIT IS REQUIRED FOR THE GREASE
 INTERCEPTORS
 A SEPARATE PERMIT IS REQUIRED FOR THE POTABLE WATER
 SERVICE BACKFLOW PREVENTER
 A SEPARATE PERMIT IS REQUIRED FOR STAND-BY GENERATOR.
 EMERGENCY STAND-BY GENERATOR. PROVIDE STORAGE CAPACITY
 AND VENTING DETAILS OF SUB BASE FUEL TANK PER WPB FBC
 107.2.1. IF STORAGE CAPACITY IS GREATER THAN 550
 GALLONS THEN DERM APPROVAL IS REQUIRED.
 PLUMBING COMMENTS: DENIED
  
 1ST REVIEW: DENIED
  
 I. RE: GENERAL
 NO COMMENT
  
 II. RE: FBC ACC
 A. A3.3
 1. LAVATORY SHALL NOT BE LOCATED IN THE CLEARANCE
 ADJACENT TO THE SHOWER CONTROLS PER FBC ACC 608.2.2.1.
 2. FLUSH CONTROL SHALL BE ON OPEN SIDE OF WATER CLOSET
 PER FBC ACC 604.6.
 3. PROVIDE INSIDE TURNING RADIUS FOR WATER CLOSET
 ACCESS IN ACCORDANCE WITH FBC ACC 304.3.
 4. NOTES FOR DRINKING FOUNTAIN DETAIL SHALL REFERENCE
 FBC 2017 EDITION, NOT 2014.
 5. TOILET ACCESSORY ?E?- HCP ACCESSIBLE SHOWER CONTROL.
 IN ACCORDANCE WITH FBC ACC 608.6, ADD VERBAGE TO NOTE
 ?FIXED OR LOW POSITION OF SHOWER HEAD TO BE MAXIMUM 48
 INCHES ABOVE SHOWER FLOOR.?
 6. SECTION AT HC SINK; 27? MIN SHOULD BE TO THE BOTTOM
 SIDE OF LEDGE, NOT TO THE CURVATURE OF THE BOWL.
 7. PER WPB FBC 107.2.1, PROVIDE ALL DIMENSIONS FOR THE
 FOLLOWING AS REQUIRED IN FBC ACC:
 A. 603.3; MIRROR TO BE MAXIMUM 40? AFF, NOT 48?.
 B. 604.4; TOP OF WATER CLOSET SEAT RANGE 17?-19?
 C. 604.5.1; SIDE GRAB BAR FOR WATER CLOSET
 E. 604.5.2; REAR GRAB BAR FOR WATER CLOSET
 F. 604.5.7; TOILET PAPER DISPENSER OUTLET
 G. 608.3.2; SHOWER GRAB BARS
 H. 608.5.2; SHOWER CONTROL LOCATION
 B. A3.4
 1. INDICATES A CABINET MOUNTED SERVICE SINK FOR THE MOP
 SINK. THE PLUMBING FIXTURE SCHEDULE INDICATES A FLOOR
 MOUNTED SINK AND PLUMBING DETAIL SHOWS THE SAME. PER
 WPB FBC 107.2.1, PLEASE CLARIFY. AS THE DETAIL ON A3.4
 SHOWS A BARRIER FREE APPLICATION IN THE ELEVATION,
 SHOULD THAT APPLICATION PREVAIL, THE SINK WOULD HAVE TO
 MEET ALL REQUIREMENTS OF FBC ACC AND THE SINK FLOOD
 LEVEL RIM ELEVATION WOULD HAVE TO COMPLY WITH THE
 REQUIREMENTS AND THE CABINET TOP HEIGHT WOULD HAVE TO
 ACCOMMODATE THAT. THE PLUMBING FIXTURE SCHEDULE WOULD
 NEED TO BE REVISED TO REFLECT THAT. THE CLEAR SPACE
 REQUIREMENTS FOR PARALLEL APPROACH AND CENTER LINE
 DIMENSION FROM SIDE WALL WOULD NEED TO BE PROVIDED.
  
 III. RE: SANITARY
 A. PER WPB FBC 107.2.1, PROVIDE DRAINAGE FOR WALK IN
 COOLER AND WALK IN FREEZER EVAPORATORS. COMPLY WITH FBC
 PL CHAPTER 8.
 B. PER FBC PL 914.2, CIRCUIT VENT CONNECTION (VERTICAL
 DRY VENT) SHALL BE LOCATED BETWEEN THE TWO MOST
 UPSTREAM FIXTURE DRAINS. THE VENT SHALL CONNECT TO THE
 HORIZONTAL BRANCH AND SHALL BE INSTALLED IN ACCORDANCE
 WITH SECTION 905. THE CIRCUIT VENT PIPE SHALL NOT
 RECEIVE THE DISCHARGE OF ANY SOIL OR WASTE. FIXTURE
 BRANCH SERVING THE CLOTHES WASHER, MOP SINK AND
 DRINKING FOUNTAIN SHALL CONNECT TO THE HORIZONTAL
 BRANCH DRAIN/VENT DOWNSTREAM OF THE TWO WATER CLOSET
 FIXTURE DRAINS IN ORDER TO COMPLY WITH FBC PL 914.5.
 C. PER FBC PL 1003.6, PROVIDE A LINT INTERCEPTOR FOR
 THE CLOTHES WASHER DRAIN.
  
 IV. RE: STORM DRAINAGE
 A. PER WPB FBC 107.2.1, PROVIDE CALCULATIONS FOR SIZING
 OF DOWNSPOUT SCUPPERS, DOWNSPOUTS AND OVERFLOW
 SCUPPERS. PROVIDE CODE OR STANDARD OR FORMULA USED FOR
 CALCULATION. INCLUDE THE VERTICAL PARAPET WALLS IN
 CALCULATIONS.
  
 V. RE: WATER SERVICE & DISTRIBUTION
 A. PROVIDE A BACKFLOW PREVENTER FOR POTABLE WATER
 SERVICE PER FBC PL 608.4.
 B. P-2.2 AND P-3.2 SHOW 1-1/2? SERVICE. C2.1 SHOWS 2?
 SERVICE. PLEASE CLARIFY AND CORRECT PLANS AS NEEDED PER
 WPB FBC 107.2.1.
 C. PER WPB FBC 107.2.1, PROVIDE DETAIL OF UNDERGROUND
 SLEEVE FOR HW, HWR, AND CW TO COOKING ISLAND. INCLUDE
 SIZE OF SLEEVE, MATERIAL, PULL STATIONS/END TERMINALS
 AND DETAIL OF HOT WATER INSULATION AND HOW APPLIED.
  
 VI. RE: IRRIGATION PLANS L2.0 AND L3.0.
 A. L.2 IRRIGATION LEGEND INDICATES PVB BACKFLOW
 PREVENTION. DEVICE SHALL BE RPZ PER WPB CCC WITH TYPE L
 OR K COPPER TO INLET AND SHALL BE LEAD FREE.
 B. L3.0 INDICATES A WELL AND PUMP AS WELL AS TWO (2)
 TYPES OF BACKFLOW PREVENTION. PLEASE REMOVE
 NON-APPLICABLE DETAILS FROM PLAN AND INDICATE THE
 APPLICABLE DEVICE AS RPZ, LEAD FREE, PER WPB CCC WITH
 TYPE L OR K COPPER TO INLET AND SHOW LOCATION ON L.2
 PER WPB FBC 107.2.1.
 C. PER WPB FBC 107.2.1, SHOW LOCATION OF RAIN SENSOR
 DEVICE, TIME CONTROLLER AND PERTINENT CONTROL VALVES
 (THAT IS TO SAY, IDENTIFY THE CONTROL VALVES ON THE
 PLAN THAT CONTROL THE NEW WORK) ON L2.0.
  
 VII. RE: PLUMBING FIXTURE SCHEDULE
 A. THE PLUMBING FIXTURE SCHEDULE ON P-4.0 INDICATES A
 FLOOR MOUNTED SINK AND DETAIL ON A-3.3 SHOWS THE SAME.
 THE DETAIL ON A3.4 SHOWS A BARRIER FREE APPLICATION IN
 THE ELEVATION. PER WPB FBC 107.2.1, PLEASE CLARIFY.
 SHOULD THE DETAIL ON A3.4 PREVAIL, THE SINK WOULD HAVE
 TO MEET ALL REQUIREMENTS OF FBC ACC AND THE SINK FLOOD
 LEVEL RIM ELEVATION WOULD HAVE TO COMPLY WITH THE
 REQUIREMENTS AND THE CABINET TOP HEIGHT WOULD HAVE TO
 ACCOMMODATE THAT. THE PLUMBING FIXTURE SCHEDULE WOULD
 NEED TO BE REVISED TO REFLECT THAT. THE CLEAR SPACE
 REQUIREMENTS FOR PARALLEL APPROACH AND CENTER LINE
 DIMENSION FROM SIDE WALL WOULD NEED TO BE PROVIDED.
 B. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER?S
 SPECIFICATION SHEETS/MANUAL FOR GDRU?S.
 C. HAND HELD SHOWER SHALL BE PROVIDED WITH A VACUUM
 BREAKER.
  
 VIII. RE: KITCHEN EQUIPMENT SCHEDULE:
 A. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER?S
 SPECIFICATION SHEETS/MANUAL FOR ALL EQUIPMENT.
 B. PER WPB FBC 107.2.1, PROVIDE FOR THE FOLLOWING ITEMS
 THIS INFORMATION; WILL BACKFLOW PREVENTION PROTECTION
 BE PROVIDED THROUGH AN AIR GAP OR BY MEANS OF A
 BACKFLOW PREVENTION DEVICE? PLEASE SPECIFY ON THE PLANS
 PER WPB FBC 107.2.1 AND IF DEVICE IS REQUIRED PROVIDE
 APPLICABLE ASSE STANDARD. IF INTERNAL BACKFLOW
 PREVENTION IS PROVIDED IN EQUIPMENT THEN INDICATE AND
 PROVIDE APPLICABLE NSF STANDARD.
 1. ITEM A, ELECTRIC TILTING BRAISING PAN
 2. ITEM E, BOILERLESS CONVECTION STEAMERS
 3. ITEM G, GAS FIRED KETTLES
 4. ITEM M, CONVEYOR DISHWASHER
  
 END OF COMMENTS
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, AA TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
  
  
  

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 1 Status P Date 2019-05-15 Cont ID  
Sent By gjohnson Date 2019-05-15 Time 16:10 Rev Time 0.00
Received By gjohnson Date 2019-05-15 Time 16:10 Sent To  
Notes
***NONE***

Review Stop P-IRRIGATE IRRIGATION REVIEW
Rev No 1 Status P Date 2019-05-15 Cont ID  
Sent By gjohnson Date 2019-05-15 Time 14:26 Rev Time 0.00
Received By gjohnson Date 2019-05-15 Time 14:26 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-05-28 Cont ID  
Sent By pvalenti Date 2019-05-28 Time 17:27 Rev Time 0.00
Received By pvalenti Date 2019-05-28 Time 17:27 Sent To  
Notes
2019-05-28 17:30:06PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 APPROVED WITH PROVISOS:
  
 1. A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO
 COMMENCEMENT OF ROOF WORK.
  
 2. THE RESIDENT INSPECTOR WILL BE REQUIRED TO OVERSEE
 ALL
 STRUCTURAL INSPECTIONS AS REQUIRED IN THE CITY
 ADMINISTRATIVE CODE 100.3 FOUNDATION THROUGH THE
 ANCHORING OF THE ROOF DECK WITH EXCEPTION OF COMPONENTS
 AND CLADDING OF WINDOWS, DOORS AND ROOFING, THESE WILL
 BE COMPLETED BY THE CITY BUILDING INSPECTORS. IF THERE
 IS ANY QUESTIONS AS TO WHAT THE RESIDENT INSPECTOR WILL
 NEED TO VERIFY AS TO STRUCTURAL INSPECTIONS PLEASE
 CONTACT KEN CONRAD ADMINISTRATOR OF THE RESIDENT AND
 SPECIAL INSPECTOR PROGRAM AT:
 KEN CONRAD
 TEL: 561?805?6666
 E?MAIL: [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-04-01 Cont ID  
Sent By jwitmer Date 2019-04-01 Time 13:10 Rev Time 0.00
Received By jwitmer Date 2019-04-01 Time 13:09 Sent To  
Notes
2019-04-01 13:10:07THE RESIDENT INSPECTOR WILL BE REQUIRED TO OVERSEE ALL
 STRUCTURAL INSPECTIONS AS REQUIRED IN THE CITY
 ADMINISTRATIVE CODE 100.3 FOUNDATION THROUGH THE
 ANCHORING OF THE ROOF DECK WITH EXCEPTION OF COMPONENTS
 AND CLADDING OF WINDOWS, DOORS AND ROOFING, THESE WILL
 BE COMPLETED BY THE CITY BUILDING INSPECTORS. IF THERE
 IS ANY QUESTIONS AS TO WHAT THE RESIDENT INSPECTOR WILL
 NEED TO VERIFY AS TO STRUCTURAL INSPECTIONS PLEASE
 CONTACT KEN CONRAD ADMINISTRATOR OF THE RESIDENT AND
 SPECIAL INSPECTOR PROGRAM AT:
 KEN CONRAD
 TEL: 561-805-6666
 E-MAIL: [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-05-28 Cont ID  
Sent By shill Date 2019-05-28 Time 15:27 Rev Time 0.00
Received By shill Date 2019-05-28 Time 15:27 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-05-24 Cont ID  
Sent By shill Date 2019-05-24 Time 14:02 Rev Time 0.00
Received By shill Date 2019-05-24 Time 13:54 Sent To  
Notes
2019-05-24 14:02:59SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
 **REVISED 5/28/19**
  
 PER FLORIDA STATUTE 471, 481
  
 1. NEW PAGES SUBMITTED IN SUBSEQUENT REVIEW CYCLES
 REQUIRE VERIFICATION.
  
 2. CIVIL PAGES - DIGITAL SIGNATURE OK,TITLE BLOCK OK
 (COFA NEXT TO THE SEAL), ADVISED REGARDING STATEMENT
 FOR DIGITAL PLANS FOR FUTURE SUBMITTALS; NO ACTION
 NEEDED.
  
 3. SURVEY OK
  
 4. LANDSCAPE AND IRRIGATION SIGNATURE OK, BUT ARE
 REQUIRED TO BE A SEPARATE PERMIT. SUBMIT A SEPARATE
 APPLICATION WITH PLANS AT THIS TIME. PLEASE ADVISE
 REGARDING VALUE FOR ITEMS OTHER THAN BMEP (INCLUDING
 ROOF). CONTACT ME IF YOU NEED FURTHER CLARIFICATION.
  
 2ND REVIEW, IT IS NOT CLEAR HOW THIS WAS ADDRESSED AS
 THERE WAS NO RESPONSE AND LANDSCAPE AND IRRIGATION
 PERMITS WERE NOT SUBMITTED, VALUES NOT PROVIDED.
  
 5. ARCHITECTURAL SHEETS; SHEETS SUBMITTED IN FUTURE
 SUBMITTALS ARE TO INCLUDE ARCHITECT BUSINESS NUMBER IN
 TITLE BLOCK (EVELYN AND ROUX ARCHITECTS, PLLC,
 AA26003652).
  
 6. STRUCTURAL PAGES OK (TITLE BLOCK, SEAL AND
 SIGNATURE).
  
 7. FMEP PAGES DIGITAL SIGNATURE OK, BUT TITLE BLOCK
 LACKS CERTIFICATE OF AUTHORIZATION FOR THOMAS E. HENZ,
 PE, INC. (C OF A IS NULL AND VOID). PER FBPE, C OF A
 REQUIRED.
  
 2ND REVIEW, IT IS NOT CLEAR HOW THIS WAS ADDRESSED.
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-04-06 Cont ID  
Sent By shill Date 2019-04-06 Time 08:09 Rev Time 0.00
Received By shill Date 2019-04-06 Time 08:05 Sent To  
Notes
2019-04-06 08:00:00**REVISED 4/9/19**
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PER FLORIDA STATUTE 471, 481
  
 1. NEW PAGES SUBMITTED IN SUBSEQUENT REVIEW CYCLES
 REQUIRE VERIFICATION.
  
 2. CIVIL PAGES - DIGITAL SIGNATURE OK, BUT LACKS
 CERTIFICATE OF AUTHORIZATION REQUIRED TO BE INCLUDED IN
 THE TITLE BLOCK.
  
 3. SURVEY OK
  
 4. LANDSCAPE AND IRRIGATION SIGNATURE OK, BUT ARE
 REQUIRED TO BE A SEPARATE PERMIT. SUBMIT A SEPARATE
 APPLICATION WITH PLANS AT THIS TIME. PLEASE ADVISE
 REGARDING VALUE FOR ITEMS OTHER THAN BMEP (INCLUDING
 ROOF). CONTACT ME IF YOU NEED FURTHER CLARIFICATION.
  
 5. ARCHITECTURAL SHEETS HAVE A DIGITAL SIGNATURE WHICH
 IS OK, BUT LACK A SEAL, LACK ARCHITECT BUSINESS NUMBER.
 PLEASE ADD TO ALL PAGES, BUT ONLY RESUBMIT PAGES WHICH
 CHANGE FOR CODE RELATED COMMENTS.
  
 6. STRUCTURAL PAGES OK (TITLE BLOCK, SEAL AND
 SIGNATURE).
  
 7. FMEP PAGES DIGITAL SIGNATURE OK, BUT TITLE BLOCK
 LACKS CERTIFICATE OF AUTHORIZATION FOR THOMAS E. HENZ,
 PE, INC. (C OF A IS NULL AND VOID). PER FBPE, C OF A
 REQUIRED.
  
  
  
  
  
2019-03-21 10:47:45ELECTRICAL SHEETS OK.

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2019-05-06 Time   Rev Time 0.00
Received By pgreilic Date 2019-05-06 Time 15:12 Sent To  
Notes
2019-05-06 15:13:11APPROVAL OF MINOR DSI AMENDMENT REQUIRED PRIOR TO
 ISSUANCE OF C.O.
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By pgreilic Date 2019-04-15 Time   Rev Time 0.00
Received By pgreilic Date 2019-04-15 Time 10:23 Sent To  
Notes
2019-04-15 10:24:02DOES NOT MATCH APPROVED PLAN PER RECENT MAJOR DSI
 AMENDMENT. REQUIRES MINOR AMENDMENT TO DSI
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]