Plan Review Details - Permit 19020934
| Plan Review Stops For Permit 19020934 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-06-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-06-07 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-06-07 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-05-14 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-05-14 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2019-05-14 16:23:10 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19020934 | | | ADD: 3030 S DIXIE SUITES 7 & 8 | | | CONT: TEKONICA INDUSTRIES INC. | | | TEL: 561-745-2858 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: 5/14/2019 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2A) COMPLIED. | | | | | | 2B) COMPLIED. | | | | | | 2C) COMPLIED | | | | | | 3A) PARTIALLY COMPLIED. SUBMIT PRODUCT APPROVALS OR | | | ENGINEERING FOR THE A/C WALL BRACKET. THE INFORMATION | | | THAT WAS SUBMITTED IS NOT A PRODUCT APPROVAL. SHEET 1.1 | | | INDICATES THE REMOVAL AND REPLACEMENT OF BRACKET FOR | | | WALL HUNG A/C CONDENSER. SHEET 4.1 DETAIL FOR WALL | | | BRACKET INDICATES THE INSTALLATION OF A MIAMI TECH WALL | | | BRACKET SYSTEM, PLEASE PROVIDE THE PRODUCT APPROVAL OR | | | ENGINEERING FOR THIS BRACKET AND ANCHOR OF THE | | | CONDENSER TO THE WALL BRACKET. | | | 2017 FBC-B 1609.1.2 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE | | | 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY | | | OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(C) WALL LOUVERS, OR OTHER PRODUCTS TESTED IN | | | REGARDS TO NEW TECHNOLOGY | | | | | | 3B) COMPLIED. | | | | | | 3C) 2017 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. FBC-B-1609.6.4.4.1 COMPONENTS | | | AND CLADDING. WIND PRESSURE FOR EACH COMPONENT OR | | | CLADDING ELEMENT IS TO BE DESIGNED FOR WIND PRESSURES | | | COMPONENTS AND ATTACHMENTS. | | | | | | 4) COMPLIED. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 6) NEW COMMENT. THE LIFE SAFETY PLAN, SHEET 3.1, IS | | | MISSING FROM THE PLAN SETS. FBC 107.2.1 | | | | | | ROBERT MCDOUGAL | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6714 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-03-12 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-03-11 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2019-03-12 11:12:34 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19020934 | | | ADD: 3030 S DIXIE SUITES 7 & 8 | | | CONT: TEKONICA INDUSTRIES INC. | | | TEL: 561-745-2858 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MARCH 12/ 2019 | | | ACTION: DENIED | | | | | | 1) SHEET 2.1 THE DESIGNER OF RECORD HAS INDICATED THIS | | | IS A LEVEL III ALTERATION. PLEASE PROVIDE CODE | | | COMPLIANCE WITH THE 2017 EXISTING BUILDING CODE | | | SECTION: | | | [BS] 907.4.1 EVALUATION AND ANALYSIS. AN ENGINEERING | | | EVALUATION AND ANALYSIS THAT ESTABLISHES THE STRUCTURAL | | | ADEQUACY OF THE ALTERED STRUCTURE SHALL BE PREPARED BY | | | A REGISTERED DESIGN PROFESSIONAL AND SUBMITTED TO THE | | | CODE OFFICIAL. | | | | | | 2A) SHEET 2.1 THE DESIGNER OF RECORD HAS NOTED ON THE | | | PLANS THE NEW DOOR OPENINGS TO THE EXTERIOR BACK OF THE | | | TENANT SPACE ARE TO BE A MIAMI-DADE NOA 17- 17-0426.02. | | | SUBMITTED WITH THE DESIGNER OF RECORDS APPROVAL IS NOA | | | 14-1021.03. PLEASE UPDATE THE NOTE ON SHEET 2.1 TO | | | COINCIDE WITH THE APPROVED NOA. 107.2.1.2 ADDITIONAL | | | INFORMATION NEEDED. | | | | | | 2B) WITHIN THE APPROVED NOA BY THE DESIGNER OF RECORD | | | THERE IS 2 DOOR LOCKING TYPES, A DEADBOLT AND LOCK OR | | | PANIC HARDWARE DEVICE, PLEASE EITHER CIRCLE ON THE | | | PRODUCT APPROVAL (NOA 17-0426.02) OR INDICATE ON SHEET | | | 2.1. 1010.1.10 PANIC AND FIRE EXIT HARDWARE.2017 FBC-B. | | | | | | 2C) PLEASE NOTE THERE IS NO WIND DESIGN CRITERIA. 2017 | | | FBC-B 1603.1.4 WIND DESIGN DATA. THE FOLLOWING | | | INFORMATION RELATED TO WIND LOADS SHALL BE SHOWN, | | | REGARDLESS OF WHETHER WIND LOADS GOVERN THE DESIGN OF | | | THE LATERAL FORCE-RESISTING SYSTEM OF THE STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS | | | DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 3A) SHEET 1.1 INDICATES THE REMOVAL AND REPLACEMENT OF | | | BRACKET FOR WALL HUNG A/C CONDENSER. SHEET 4.1 DETAIL | | | FOR WALL BRACKET INDICATES THE INSTALLATION OF A MIAMI | | | TECH WALL BRACKET SYSTEM, PLEASE PROVIDE THE PRODUCT | | | APPROVAL OR ENGINEERING FOR THIS BRACKET AND ANCHOR OF | | | THE CONDENSER TO THE WALL BRACKET. | | | 2017 FBC-B 1609.1.2 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE | | | 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY | | | OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(C) WALL LOUVERS, OR OTHER PRODUCTS TESTED IN | | | REGARDS TO NEW TECHNOLOGY | | | | | | 3B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE | | | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 3C) 2017 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. FBC-B-1609.6.4.4.1 COMPONENTS | | | AND CLADDING. WIND PRESSURE FOR EACH COMPONENT OR | | | CLADDING ELEMENT IS TO BE DESIGNED FOR WIND PRESSURES | | | COMPONENTS AND ATTACHMENTS. | | | | | | 4) THERE ARE MULTIPLE OF LOOSE SHEETS (1.1, 4.1 & 6.1) | | | IN THE PERMIT PACKAGE, PLEASE PROVIDE ADDITIONAL | | | INFORMATION ON THESE SHEETS? 107.2.1.2 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-20 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-20 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-14 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-14 |
Time |
08:36 |
Sent To |
I |
|
| Notes |
| 2019-06-14 08:26:20 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE AND | | | INDIVIDUAL PANELS, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. RISER SHOWS | | | TWO 200 AMP METERS TO UNITS, WHERE ARE THE LOADS FOR | | | THESE? NEW 100 AMP PANEL B SHOWS A NEW RTU, BUT ONLY | | | THE BLOWER MOTOR LOAD IS INCLUDED. THE LARGER OF AC OR | | | HEAT LOAD SHOULD BE INCLUDED IN THIS PANEL LOAD. | | | PROVIDE SPEC SHEET FOR NEW RTU WITH ELECTRICAL | | | REQUIREMENTS. NEC 110.3, 215.2, 220, 220.60, 408.30; | | | WPB FBC 107.2.1 (4TH REVIEW, STILL NOT CLARIFIED OR | | | CORRECTED. LOAD CALCULATION FOR 600 AMP MAIN NOT | | | PROVIDED. ADDITIONALLY, THE PANEL SCHEDULE SHOWS | | | CIRCUITS A-21, A-23, A-25, AND A-27 AS SPARES. WHY IS | | | THERE NO LOAD INCLUDED FOR THESE STYLING STATIONS? THIS | | | WOULD NOT BE CALCULATED AT 180 VA PER RECEPTACLE AS | | | THIS IS FOR A SPECIFIC LOAD. ALSO, THERE IS NOT LOAD | | | INCLUDED FOR THE EXHAUST FANS SHOWN ON THE MECHANICAL | | | PLAN. NEC 220, 220.14(A) PROVIDE CLARIFICATION AND | | | CORRECTIONS.) | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-06-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-07 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-07 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2019-06-07 13:20:23 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE AND | | | INDIVIDUAL PANELS, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. RISER SHOWS | | | TWO 200 AMP METERS TO UNITS, WHERE ARE THE LOADS FOR | | | THESE? NEW 100 AMP PANEL B SHOWS A NEW RTU, BUT ONLY | | | THE BLOWER MOTOR LOAD IS INCLUDED. THE LARGER OF AC OR | | | HEAT LOAD SHOULD BE INCLUDED IN THIS PANEL LOAD. | | | PROVIDE SPEC SHEET FOR NEW RTU WITH ELECTRICAL | | | REQUIREMENTS. NEC 110.3, 215.2, 220, 220.60, 408.30; | | | WPB FBC 107.2.1 (3RD REVIEW, STILL NOT CLARIFIED. LOAD | | | CALCULATION FOR 600 AMP MAIN NOT PROVIDED. | | | ADDITIONALLY, THE PANEL SCHEDULE SHOWS CIRCUITS A-21, | | | A-23, A-25, AND A-27 AS SPARES. WHY IS THERE NO LOAD | | | INCLUDED FOR THESE STYLING STATIONS? THIS WOULD NOT BE | | | CALCULATED AT 180 VA PER RECEPTACEL AS THIS IS FOR A | | | SPECIFIC LOAD. NEC 220.14(A) PROVIDE CLARIFICATION AND | | | CORRECTIONS.) | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 7. CIRCUITS FROM UNIT 8 (PANEL B) ARE SHOWN FEEDING | | | LOADS IN THE UNIT 7, AND VICE VERSA, WHICH IS A CODE | | | VIOLATION. EACH OCCUPANT SHALL HAVE READY ACCESS TO ALL | | | OVERCURRENT DEVICES PROTECTING THE CONDUCTORS SUPPLYING | | | THAT OCCUPANCY. PROVIDE CORRECTION. NEC 240.24(B) | | | 8. EACH TENANT SPACE REQUIRES A SIGN CIRCUIT. PROVIDE | | | DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC 600.5; FBC | | | EC 405.2.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-15 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-15 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2019-05-15 10:47:32 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE AND | | | INDIVIDUAL PANELS, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. RISER SHOWS | | | TWO 200 AMP METERS TO UNITS, WHERE ARE THE LOADS FOR | | | THESE? NEW 100 AMP PANEL B SHOWS A NEW RTU, BUT ONLY | | | THE BLOWER MOTOR LOAD IS INCLUDED. THE LARGER OF AC OR | | | HEAT LOAD SHOULD BE INCLUDED IN THIS PANEL LOAD. | | | PROVIDE SPEC SHEET FOR NEW RTU WITH ELECTRICAL | | | REQUIREMENTS. NEC 110.3, 215.2, 220, 220.60, 408.30; | | | WPB FBC 107.2.1 (INFORMATION NOT CLARIFIED. ARE THERE | | | TWO 200 AMP METERS FEEDING OTHER LOADS TO UNIT 7 AND 8, | | | WHERE ARE THE METERS FOR THE 100 AMP SINGLE PHASE | | | PANELS, AND WHAT IS THE LOAD OF THE 600 AMP MAIN? ALSO, | | | WHEN LOADS STATED ARE ADDED TOGETHER, THE AMOUNT IS | | | DIFFERENT THAN WHAT IS STATED FOR A PHASE OF EACH | | | PANEL. THE CORRECTED MATH SHOWS THE PANEL AND FEEDERS | | | AS OVERLOADED. PROVIDE CLARIFICATIONS AND CORRECTIONS.) | | | 2. PROVIDE LOCATION OF ALL PANELS IN UNITS. PROVIDE | | | PANEL SCHEDULES FOR ALL PANELS INDICATING ANY NEW OR | | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4 (NO REPLY TO THIS COMMENT.) | | | 3. SHOW WINDOW RECEPTACLES ARE SHOWN ON PANEL SCHEDULE, | | | BUT NOT SHOWN ON PLAN. PROVIDE CORRECTION. WPB FBC | | | 107.2.1; NEC 210.62 (COMMENT NOT ADDRESSED. PROVIDE | | | SHOW WINDOW OUTLETS PER CODE.) | | | 4. ALL RECEPTACLES WITHIN 6 FEET OF A SINK MUST BE GFCI | | | PROTECTED. PROVIDE CORRECTION. NEC 210.8 (RECEPTACLE | | | OOUTLET ADJACENT TO HAIR WASH AREA NOT CORRECTED.) | | | 5. CORRECTED. | | | 6. PROVIDE COPY OF CONTRACT TO VERIFY VALUE OF WORK FOR | | | TOTAL PROJECT. WPB FBC 109.3 (NOT PROVIDED.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-16 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-15 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2019-03-16 10:50:27 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE AND | | | INDIVIDUAL PANELS, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. RISER SHOWS | | | TWO 200 AMP METERS TO UNITS, WHERE ARE THE LOADS FOR | | | THESE? NEW 100 AMP PANEL B SHOWS A NEW RTU, BUT ONLY | | | THE BLOWER MOTOR LOAD IS INCLUDED. THE LARGER OF AC OR | | | HEAT LOAD SHOULD BE INCLUDED IN THIS PANEL LOAD. | | | PROVIDE SPEC SHEET FOR NEW RTU WITH ELECTRICAL | | | REQUIREMENTS. NEC 110.3, 215.2, 220, 220.60, 408.30; | | | WPB FBC 107.2.1 | | | 2. PROVIDE LOCATION OF ALL PANELS IN UNITS. PROVIDE | | | PANEL SCHEDULES FOR ALL PANELS INDICATING ANY NEW OR | | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4 | | | 3. SHOW WINDOW RECEPTACLES ARE SHOWN ON PANEL SCHEDULE, | | | BUT NOT SHOWN ON PLAN. PROVIDE CORRECTION. WPB FBC | | | 107.2.1; NEC 210.62 | | | 4. ALL RECEPTACLES WITHIN 6 FEET OF A SINK MUST BE GFCI | | | PROTECTED. PROVIDE CORRECTION. NEC 210.8 | | | 5. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63 | | | 6. PROVIDE COPY OF CONTRACT TO VERIFY VALUE OF WORK FOR | | | TOTAL PROJECT. WPB FBC 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-06-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-06-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-06-06 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-04-26 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-04-26 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2019-04-26 10:29:26 | PERMIT # 19020934 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENTS: ORIGINAL COMMENTS NOT ADDRESSED IN | | | RESUBMISSION. | | | | | | 1) SHEET C.1: SHEET INDEX SHOWS A LIFE SAFETY PLAN | | | IDENTIFIED AS SHEET 3.1. THIS SHEET WAS NOT PROVIDED IN | | | THIS SUBMISSION. SHEET 2.1 IS DUPLICATED. | | | | | | 2) PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVEL ETC. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-02-26 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-02-26 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2019-02-26 10:31:54 | PERMIT # 19020934 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) SHEET C.1: SHEET INDEX SHOWS A LIFE SAFETY PLAN | | | IDENTIFIED AS SHEET 3.1. THIS SHEET WAS NOT PROVIDED IN | | | THIS SUBMISSION. SHEET 2.1 IS DUPLICATED. | | | | | | 2) PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVEL ETC. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2019-06-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-10 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-06-10 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2019-06-10 15:38:52 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-29 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-29 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2019-04-29 10:52:34 | GAS 2ND REVIEW**DENIED** | | | | | | | | | *FL ST 553.80 (B)2B WITH RESPECT TO EVALUATION OF | | | DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT | | | FINDS IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH | | | THE FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW. | | | | | | | | | | | | 1) INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 | | | | | | 2) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) | | | | | | 3) 2ND REQUEST**SUBMIT TWO COPIES OF THE APPLICABLE | | | SIZING TABLES USED TO SIZE THE GAS SYSTEM OR PLACE A | | | NOTE ON THE PLANS/DRAWINGS SPECIFYING WHICH SIZING | | | TABLE(S) FROM THE GAS CODE OR OTHER STANDARD THAT WERE | | | USED IN THE DESIGN OF THIS GAS SYSTEM. REFER TO THE | | | 2017 FBC-FUEL GAS SECS. 401.4, 401.8, 402.3, AND TABLES | | | 402.4 (1) THRU 402.4 (37) | | | | | | 4) 2ND REQUEST**GAS TANKLESS CALLED OUT ON SHT.5.1 AS | | | 140,000 BTU'S. INSTALLATION MANUAL PROVIDE DOES NOT | | | LIST A MODEL WITH THAT BTU RATING. PLEASE CLARIFY AND | | | CALL OUT MODEL OF TANKLESS BEING USED. FBC 107.2.1 | | | | | | 5) 2ND REQUEST**DRYER SPEC SUBMITTED DOES NOT SHOW | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, | | | | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-13 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-13 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2019-03-13 11:55:47 | GAS 1ST REVIEW**DENIED** | | | | | | THERE IS A GAS DRYER AND GAS TANKLESS WATER HEATER ON | | | THIS PLAN BUT NOT SUPPORTING DOCUMENTS SUPPLIED ON THIS | | | PLAN. PROVIDE A COMPLETE GAS ISOMETRIC DRAWNING INCLUDE | | | SIZE, PIPING MATERIAL AND SIZING CHARTS BEING USED. | | | PLEASE INCLUDE THE MANUFACTURE INSTALLATION MANUALS AS | | | WELL. FBC 107.3.5 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | | | | SAMANTHA HILL | | | CHIEF PLANS EXAMINER | | | 561-805-6724 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-06-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-06-18 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2019-06-20 09:49:46 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-06-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-06-11 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2019-06-12 15:30:00 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-06-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-10 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-06-03 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-05-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-04-22 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-03-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-20 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-03-12 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-03-11 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-06-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-06-07 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-06-07 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-02 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-01 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2019-05-02 16:29:42 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19020934 | | | 5/2/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE REVISED SUBMITTED MECHANICAL PLAN SHOWS THESE | | | PRIOR AND NEW DEFICIENCIES: | | | | | | A) THE REQUESTED EXHAUST VENTILATION CALCULATIONS WERE | | | NOT PROVIDED- SEE COMMENT #1 FROM THE 1ST REVIEW | | | PRINTED HERE- 1) SHEET 4.1: EF-2 AT 150 CFMS APPEARS TO | | | BE UNDERSIZED FOR THE REQUIRED EXHAUST RATE OF 0.60 | | | CFMS PER SF. FOR THE SALON AREA- SEE TABLE 403.3.1.1 | | | AND PROVIDE CALCULATIONS. | | | | | | B) NO EXHAUST HAS BEEN PROVIDED FOR THE TREATMENT ROOM- | | | TABLE 403.3.1.1 FBC M. | | | | | | C) NO OUTSIDE AIR DUCT OR AUTOMATIC CONTROL DAMPER HAVE | | | BEEN PROVIDED FOR THE NEW 5-TON AC SYSTEM- TABLE | | | 403.3.1.1 FBC M & SECTION C403.2.4.3 FBC EC. | | | | | | D) CLARIFY THE LOCATION OF THE NEW 5-TON CONDENSER. IS | | | THE UNIT TO BE GROUND MOUNTED OR WALL BRACKET MOUNTED? | | | THE WALL BRACKET DETAIL SHOWN IS FOR A PACKAGE UNIT. IN | | | EITHER CASE- WALL OR GROUND- COMPLETE ENGINEERING IS | | | REQUIRED- SECTION 301.15 FBC M. PLEASE NOTE THAT THE | | | CONDENSER BELOW THE SLOPING ROOF MAY BE DETRIMENTAL TO | | | THE FUNCTION OF THE SYSTEM AND MAY BE | | | | | | INCONSISTENT WITH THE MANUFACTURER'S INSTALLATION AND | | | WARRANTY GUIDELINES. SUBMIT DOCUMENTATION VERIFYING | | | COMPLIANCE- SEE SECTION 304.1 FBC M. | | | | | | E) THE NEW ENERGYGAUGE COMPLIANCE REPORT INDICATES THE | | | NEW 5-TON SYSTEM IS 17 SEER, HOWEVER THE SCHEDULE ON | | | THE PLAN INDICATES 14 SEER. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-19 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-19 |
Time |
08:45 |
Sent To |
I |
|
| Notes |
| 2019-03-19 12:23:39 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19020934 | | | 3/19/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 4.1: EF-2 AT 150 CFMS APPEARS TO BE UNDERSIZED | | | FOR THE REQUIRED EXHAUST RATE OF 0.60 CFMS PER SF. FOR | | | THE SALON AREA- SEE TABLE 403.3.1.1 AND PROVIDE | | | CALCULATIONS. | | | | | | 2) 4.1: PROVIDE AUTOMATICALLY CONTROLLED SHUTOFF | | | DAMPERS FOR THE OUTDOOR AIR INTAKES ON THE RTU'S - | | | SECTION C403.2.4.3 FBC-17 ENERGY CONSERVATION. | | | | | | 3) 4.1: THE LOCATIONS OF THE RTU'S AND DUCT TRUNKS | | | BELOW THE SLOPING ROOF MAY BE DETRIMENTAL TO THE | | | FUNCTION OF THE SYSTEM AND MAY BE INCONSISTENT WITH THE | | | MANUFACTURER'S INSTALLATION AND WARRANTY GUIDELINES. | | | SUBMIT DOCUMENTATION VERIFYING COMPLIANCE- SEE SECTION | | | 304.1 FBC M. | | | | | | 4) 4.1: SITE SPECIFIC ENGINEERING IS REQUIRED FOR | | | INSTALLATION OF THE RTU AND WALL BRACKET- SECTION | | | 301.15 FBC M. A) PROVIDE THE WIND LOAD DESIGN CRITERIA | | | PER SECTION 1609 FBC B. B) PROVIDE A FL. PRODUCT | | | APPROVAL OR MIAMI-DADE NOA FOR THE BRACKET. C) REQUIRED | | | DETAILS- BRACKET TO WALL ATTACHMENT, AND RTU TO BRACKET | | | ATTACHEMNT. | | | | | | 5) THE SUMMARY AC LOAD CALCULATIONS MUST BE SIGNED AND | | | SEALED BY A F. LICENSED ENGINEER- SECTION C403.2.1 | | | EXCEPTION FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-06-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-10 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-06-10 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-29 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-29 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2019-04-29 11:55:23 | PLUMBING 1ST REVIEW**DENIED** | | | | | | ***FL ST 553.80 (B)2B WITH RESPECT TO EVALUATION OF | | | DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT | | | FINDS IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH | | | THE FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW. | | | | | | | | | 1) 2ND REQUEST** PLAN DOES NOT SHOW THE REQUIRED HI-LO | | | DRINKING FOUNTAIN AS REQUIRED IN FBC-P 410.3. THE | | | BOTTLE WATER DISPENCER'S SHOWN IS ONLY ALLOWED TO | | | REPLACED UP TO 50% OF THE REQUIRED NUMBER OF DRINKING | | | FOUNTAINS REQUIRED. FBC-P 410.4 | | | | | | 2) 2ND REQUEST SHT.2.1 UNDER TOILET ACCESSORY SCHEDULE | | | HAS SOME INCORRECT INFORMATION FOR THE GRAB BARS. SHOW | | | GRAB BAR HEIGHT AS 33"-36" TO THE TOP OF GRIPPING | | | SURFACE. GB CALLS OUT 33" TO THE CENTER BUT GB1 CALLS | | | OUT 33"-36" TO THE CENTER WHICH IF MOUNTED @ 36" WOULD | | | HAVE THE GRIPPING SURFACE TO HIGH. FBC-ACC 609.4 | | | | | | 3) ANSWERED | | | | | | 4) 2ND REQUEST PROVIDE THE MANUFACTURE INSTALLATION | | | MANUAL FOR THE GAS TANKLESS WATER HEATER. WHICH | | | MODEL.FBC 107.3.5 | | | | | | 5) 2ND REQUEST PROVIDE THE MANUFACTURES INSTALLATION | | | MAUNAL SHOWING THE HAIR WAS STATIONS COMPLY WITH | | | FBC-P423.3. SHOW AS TEMP LIMITED BY A ASSE 1070 DEVICE. | | | | | | 6) 2ND REQUEST PROVIDE A SEPERATE SIZED WATER ISOMETRIC | | | DRAWNING WITH PIPE SIZING. FBC 107.3.5 | | | | | | 7) 2ND REQUESTSHT 5.1 WASHING MACHINE DETAIL CALLS OUT | | | 3" PIPING TO WASHING MACHINE BOX BUT NOTE TOP CENTER | | | SAAYS PROPOSED WASHING WITH 2" PVC. PLEASE CLEARIFY. | | | FBC 107.3.5 | | | | | | 8) NEW COMMENT: PROVIDE A LINT INTERCEPTOR FOR THE | | | WASHING MACHINE. PROVIDE COMPLETE INSTALLATION MANUALS | | | AND REVISE SANITARY ISOMETRIC DRAWING. FBC 1003.1, | | | 1003.2, 1003.6 | | | | | | | | | PLEASE PROVIDE A NARRATIVE REAPONSE TO ALL COMMENTS. I | | | WOULD RECOMMENDED A MEETING WITH PLAN REVIEW STAFF | | | BEFORE RESUBMITTING . | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-13 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-13 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2019-03-13 12:29:09 | PLUMBING 1ST REVIEW**DENIED** | | | | | | PLAN REVIEW WAS BASED ON THIS BEING A LEVEL LLL | | | RENOVATION COMPLYING WITH THE FBC 2017 6TH ED. | | | | | | 1) PLAN DOES NOT SHOW THE REQUIRED HI-LO DRINKING | | | FOUNTAIN AS REQUIRED IN FBC-P 410.3. THE BOTTLE WATER | | | DISPENCER SHOWN IS ONLY ALLOWED TO REPLACED UP TO 50% | | | OF THE REQUIRED NUMBER OF DRINKING FOUNTAINS REQUIRED. | | | FBC-P 410.4 | | | | | | 2) SHT.2.1 UNDER TOILET ACCESSORY SCHEDULE HAS SOME | | | INCORRECT INFORMATION FOR THE GRAB BARS. BEING THAT YOU | | | HAVE A CORRECT TOILET ROOM ELEVATIONS ON SHT5.1 YOU CAN | | | REMOVE THE NOTES OR CORRECT AS FOLLOWED. GB-1 (SIDE | | | BAR) 42" BAR MUST BE MOUNT @ 12" TO GET THE REQUIRED | | | OVERALL 54".FBC-A 604.5.1 (2B) GB-1 (REAR) 36" GRAB BAR | | | SHALL BE MOUNT 12" FOR CENTER OF TOILET BEING THAT THE | | | TOILET IS PERMITTED TO BE 16"-18" IT CAN BE 4'-6' FROM | | | THE SIDE WALL. FBC-A 604.5.2 | | | | | | 3) THE EMPLOYEE BREAKROOM SINK SHALL COMPLY WITH | | | FLORIDA ACCESSIBILITY CHAPTER 6 SAME AS THE WAITING | | | ROOM DOES. PLEASE PROVIDE CLEAR FLOOR SPACE AND SHOW | | | CABINET HEIGHT DETAIL LISTING MAX 34".FBC-A 606.2, | | | 606.3 | | | | | | 4) PROVIDE THE MANUFACTURE INSTALLATION MANUAL FOR THE | | | GAS TANKLESS WATER HEATER. FBC 107.3.5 | | | | | | 5) PROVIDE THE MANUFACTURES INSTALLATION MAUNAL SHOWING | | | THE HAIR WAS STATIONS COMPLY WITH FBC-P423.3 AND ARE | | | TEMP LIMITED BY A ASSE 1070 DEVICE. | | | | | | 6) PROVIDE A SEPERATE SIZED WATER ISOMETRIC DRAWNING. | | | FBC 107.3.5. IF THE DEVELOPED LENGHT OF THE HOT WATER | | | LINE IS OVER 50' A RECIRCULATION SYSTEM WAS ALSO BE | | | INSTALL. FBC-P 607.2 AND INSULATED WITH 1" WALL | | | COMPLYING WITH FBC-ENERGY C404.6 | | | | | | 7) SHT 5.1 WASHING MACHINE DETAIL CALLS OUT 3" PIPING | | | TO WASHING MACHINE BOX BUT NOTE TOP CENTER SAAYS | | | PROPOSED WASHING WITH 2" PVC. PLEASE CLEARIFY. FBC | | | 107.3.5 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | | | | SAMANTHA HILL | | | CHIEF PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2019-05-14 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2019-05-14 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2019-05-14 17:03:16 | PER MC |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-06 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-03-06 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-03-06 |
Time |
13:48 |
Sent To |
PC |
|
| Notes |
|
|
|