Plan Review Details - Permit 19020913
| Plan Review Stops For Permit 19020913 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-18 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-18 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-15 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-15 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2019-03-15 10:44:54 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. THE WINDOW LOAD CHART IS NOT SIGNED BY THE ENGINEER. | | | PLEASE RE-SUBMIT WITH A VALID DIGITAL SIGNATURE. FBC | | | 107 | | | | | | 2. THE GLASS TYPE INDICATED DO NOT MEET THE WIND LOAD | | | PRESSURE REQUIRED ON THE WIND LOAD CHART. PLEASE HAVE | | | THE ENGINEER SIGN THE WIND LOAD CHART AND INDICATE THE | | | EXTERIOR WIND PRESSURE. THEN VERIFY THE PRODUCT AND | | | GLASS TYPE SUBMITTED TO MEET THE REQUIRED EXTERIOR WIND | | | PRESSURES. FBC 107 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-04 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-28 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2019-03-04 08:39:51 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SPECIFY GLASS TYPE ON NOA 17-0731.06 TO DETERMINE | | | WIND LOADS. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-15 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-11 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-04 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-20 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-18 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-18 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-15 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-15 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2019-03-15 10:45:44 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. THE WINDOW LOAD CHART IS NOT SIGNED BY THE ENGINEER. | | | PLEASE RE-SUBMIT WITH A VALID DIGITAL SIGNATURE. FBC | | | 107 | | | | | | 2. THE GLASS TYPE INDICATED DO NOT MEET THE WIND LOAD | | | PRESSURE REQUIRED ON THE WIND LOAD CHART. PLEASE HAVE | | | THE ENGINEER SIGN THE WIND LOAD CHART AND INDICATE THE | | | EXTERIOR WIND PRESSURE. THEN VERIFY THE PRODUCT AND | | | GLASS TYPE SUBMITTED TO MEET THE REQUIRED EXTERIOR WIND | | | PRESSURES. FBC 107 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-03-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-04 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-28 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2019-03-04 08:42:20 | BUILDING PLAN REVIEW - DIGITAL SIGNATURES | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | SIGNATURE AND SEAL ON ENGINEERING IS NOT VALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | |
|
|
|