Plan Review Details - Permit 19020703
| Plan Review Stops For Permit 19020703 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-07-24 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-07-24 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2020-07-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-07-10 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-07-10 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-06-25 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-06-25 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2020-06-25 16:40:01 | RESIDENTIAL (R3) ADDITION/ALTERATION, 6TH BUILDING | | | REVIEW CHECKLIST | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1) REVISED PLANS SUBMITTED NOW DON'T HAVE THE | | | ENGINEER'S SEAL AND SIGNATURE. NEED TO PROVIDE PLANS | | | WITH ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED | | | BY CHAPTER 471 F.S. | | | | | | 2) ENERGY CALCULATIONS SUBMITTED (SEC. 1106 | | | FBC-EXISTING BUILDING. AND SEC. R101.5 FBC-ENERGY | | | CONSERVATION): | | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY | | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2019-12-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-12-09 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-12-09 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2019-12-09 17:03:37 | RESIDENTIAL (R3) ADDITION/ALTERATION, 5TH BUILDING | | | REVIEW CHECKLIST | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES APPLY. CONTRACTOR TO | | | ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME OR | | | IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | | ISSUANCE. | | | | | | ****IMPORTANT***** | | | ENERGY CALCULATIONS NEED TO BE SIGNED/DATED BY THE | | | OWNER PRIOR TO PASSING THE BUILDING REVIEW WITH | | | PROVISO. | | | | | | | | | 1- PLANS SUBMITTED NOW DON'T SPECIFY THE TYPE AND SIZE | | | OF THE NEW BEDROOM WINDOWS. THE COMMENT ON THE FIRST | | | REVIEW DONE ON 03/11/19 WAS THAT THE 37"X52.5" SINGLE | | | HUNG WINDOWS SPECIFIED ON THE WINDOW SCHEDULE DON'T | | | COMPLY WITH THE EGRESS REQUIREMENTS. PLANS SUBMITTED | | | NOW DON'T HAVE THE WINDOW SCHEDULE OR SPECIFICATIONS | | | FOR THE EGRESS WINDOWS. NEED TO SPECIFY TYPE AND SIZE | | | OF EGRESS WINDOWS. SEC. 1101.1 FBC-EXISTING BUILDING | | | AND SEC. R310.2.1 FBC-RESIDENTIAL. | | | | | | 2- ORIGINAL PLANS HAD FRAMING DETAILS AND | | | SPECIFICATIONS FOR THE WINDOW OPENINGS. PLANS SUBMITTED | | | NOW DON'T HAVE THE WINDOW OPENING FRAMING DETAILS. | | | PROVIDE COMPLETE WINDOW OPENING FRAMING DETAILS AND | | | SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS AND | | | CONNECTORS. SEC. 1101.1 FBC-EXISTING BUILDING AND SEC. | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | 3- ENERGY CALCULATIONS SUBMITTED (SEC. 1106 | | | FBC-EXISTING BUILDING. AND SEC. R101.5 FBC-ENERGY | | | CONSERVATION): | | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED | | | AND DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY | | | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS | | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION. | | | | | | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | | | | C) NUMBER OF BEDROOMS IS INCORRECT. REVISE ITEM #4 ON | | | PAGE 1 OF 4. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | NOTE: ENERGY CALCULATIONS SUBMITTED ARE FOR THE BEDROOM | | | ADDITION ONLY (336 S. F.). THERE IS ONLY ONE BEDROOM. | | | | | | D) WALL INFORMATION SHOWN ON ITEM #9 ON PAGE 1 OF 4 IS | | | INCORRECT. SEE PLANS AND REVISE AS REQUIRED TO MATCH. | | | THERE IS A LOW CONCRETE BLOCK WALL AND THE REST OF THE | | | WALL IS WOOD FRAME. SEC. R101.5.1.1.2 FBC- ENERGY | | | CONSERVATION. | | | | | | E) CEILING INFORMATION SHOWN ON ITEM # 10 ON PAGE 1 OF | | | 4 IS INCORRECT.. R-30 BUTT INSULATION DOESN'T FIT ON | | | EXISTING 2"X8" CEILING JOISTS. R-30 INSULATION IS | | | ABLOUT 9-1/2" INCHES THICK. THEREFORE, IT DOESN'T ALLOW | | | THE ONE INCH CLEARANCE REQUIRED FOR CROSS VENTILATION. | | | COORDINATE WITH PLANS AND REVISE AS REQUIRED. SEC. | | | R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | | | F) THE SPACES INFORMATION ON PAGE 2 OF 4 IS INCORRECT. | | | ENERGY CALCULATIONS SUBMITTED ARE FOR THE BEDROOM | | | ADDITION ONLY (336 S. F.). THERE IS NOT KITCHEN IN THE | | | BEDROOM. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- | | | ENERGY CONSERVATION. | | | | | | G) REVISE THE ROOF TYPE SPECIFIED ON PAGE 2 OF 4 TO | | | MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | THE BEDROOM DOESN'T HAVE A HIP ROOF. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION. | | | | | | H) REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 4. THE | | | RATIO IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL. | | | OR, PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE | | | COMPLETE DOCUMENTATION SHOWING COMPLIANCE WITH THE | | | 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON SEC. | | | R806.2. | | | | | | I) REVISE THE DOORS INFORMATION SPECIFIED ON PAGE 3 OF | | | 4 TO MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | NOTE: THERE ARE NO EXTERIOR DOORS IN THE BEDROOM.. | | | | | | J) REVISE THE WINDOWS INFORMATION SPECIFIED ON PAGE 3 | | | OF 4 TO MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | NOTE: THERE ARE NO WINDOWS ON THE EAST SIDE OF THE | | | BEDROOM.. | | | | | | 4- ENGINEER OF RECORD TO SPECIFY ON PLANS THE CEILING | | | AND WALLS INSULATION AS REQUIRED BY SEC. 1101.1 | | | FBC-EXISTING BUILDING AND SEC. R103.2 FBC-ENERGY | | | CONSERVATION.. | | | | | | 5- ORIGINAL PLANS HAD FRAMING DETAILS AND | | | SPECIFICATIONS FOR THE NEW STEPS. PLANS SUBMITTED NOW | | | DON'T HAVE THIS DETAIL. PROVIDE DETAIL SHOWING THE | | | RISER AND TREAD DIMENSIONS. SEC. 1101.1 FBC-EXISTING | | | BUILDING AND SEC. R311.7.5 FBC-RESIDENTIAL. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
CTHROOP |
Date |
2019-08-22 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-22 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2019-08-22 16:48:02 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | REPEAT COMMENTS | | | | | | 1. PROVIDE ENERGY SUBMITTAL. - 4TH REQUEST | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | | | | NOTICE: 4 X FEES MAY APPLY | | | | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-31 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-31 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2019-07-31 15:07:39 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | REPEAT COMMENTS | | | | | | 1. PROVIDE ENERGY SUBMITTAL. | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | | | | 2. PROVIDE PRODUCT APPROVALS INCLUDING INSTALLATION | | | INSTRUCTIONS. | | | | | | NOTE TO DESIGNER: | | | | | | PRODUCT APPROVALS MAY BE DEFERRED. DESIGNER SHALL LIST | | | ALL PRODUCT APPROVALS TO BE DEFERRED ON PLAN. PRODUCT | | | APPROVALS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW | | | AND APPROVAL PRIOR TO INSTALLATION. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | PROVISO | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | NOTICE: 4 X FEES MAY APPLY | | | | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-30 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-30 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2019-05-30 08:51:52 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- OK | | | | | | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. 1106 FBC-EXISTING BUILDING. AND SEC. R101.4.2 | | | AND R101.5 FBC-ENERGY CONSERVATION. - REPEAT COMMENT | | | | | | 3- OK | | | | | | 4- OK | | | | | | 5- OK | | | | | | 5 - (A) SINGLE HUNG WINDOWS. INFORMATION SUBMITTED IS | | | INCOMPLETE. NEED TO PROVIDE COMPLETE FLORIDA PRODUCT | | | APPROVAL (2 COPIES), INCLUDING THE FLORIDA PRODUCT | | | APPROVAL COVER PAGE THAT CORRESPONDS TO THE DRAWINGS | | | SUBMITTED. THE FLORIDA PRODUCT APPROVAL IS REQUIRED | | | BECAUSE IT SHOWS IF PRODUCT IS APPROVED AND CURRENT | | | CODE IN EFFECT. | | | | | | 6- OK | | | | | | 7- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR | | | REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-11 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-08 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2019-03-08 18:57:26 | RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- EXISTING PARTIAL FLOOR PLAN SHOWS EXISTING "GUEST | | | ROOM". THERE ARE NO PERMITS FOR THE CONVERSION OF THIS | | | SPACE TO A GUEST ROOM. THERE IS AN EXPIRED PERMIT | | | (#04070675) FOR THE CONVERSION OF THE EXISTING CARPORT | | | TO GARAGE. THE PERMIT IS EXPIRED. THE EXPIRED PERMIT | | | NEEDS TO BE TAKEN CARE OF SINCE IT LOOKS LIKE SOME WORK | | | WAS DONE, BUT THERE WERE NO INSPECTIONS. AND, NOW PLANS | | | SUBMITTED SHOW THAT IT LOOKS LIKE THERE WAS ADDITIONAL | | | WORK DONE WITHOUT PERMITS. ACCORDING TO PLANS | | | SUBMITTED, THE PROPOSED GARAGE WAS CONVERTED TO A | | | BEDROOM. THE EXPIRED PERMIT CAN BE INCORPORATED INTO | | | THIS PERMIT APPLICATION IF ALL WORK THAT WAS DONE | | | WITHOUT PERMIT IS REFLECTED ON THE PLANS SUBMITTED NOW | | | AND SHOW EVERYTHING AS NEW INSTEAD OF EXITING. THIS WAY | | | THE EXPIRED PERMIT MAY BE REVOKED AND THE PROPER | | | INSPECTIONS CAN BE PERFORMED. SEC. 105.1 CITY | | | AMENDMENTS. | | | | | | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. 1106 FBC-EXISTING BUILDING. AND SEC. R101.4.2 | | | AND R101.5 FBC-ENERGY CONSERVATION. | | | | | | 3- BEDROOM EGRESS WINDOWS DON'T COMPLY WITH THE CLEAR | | | OPENING REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. | | | SINGLE HUNG WINDOW #1 SHOWN ON THE WINDOW SCHEDULE (37 | | | X 52.5) DOESN'T PROVIDE THE MIN. CLEAR HEIGHT OPENING | | | OF 24". ALSO, OPENING DIMENSIONS SHOWN ON THE "INFILLED | | | GARAGE DOOR OPENING ELEVATION" ON SHEET S2 DON'T SEEM | | | TO WORK WITH PROPOSED WINDOW SIZE. COORDINATE | | | DIMENSIONS WITH REQUIRED EGRESS WINDOW SIZE. | | | | | | 4- STRUCTURAL WALL SECTIONS PROVIDED ARE MISSING SOME | | | INFORMATION. PROVIDE COMPLETE DETAILS AND | | | SPECIFICATIONS ON ALL WALL SECTIONS PROVIDED. CLEARLY | | | SPECIFY TOP AND BOTTOM CONNECTIONS FOR ALL FRAMING | | | MEMBERS. CLEARLY SPECIFY ALL CONNECTORS SHOWN ON THE | | | "INFILLED GARAGE DOOR OPENING ELEVATION" ON SHEET S2. | | | SEC. R601.2 FBC-RESIDENTIAL. | | | | | | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL) | | | | | | A)SINGLE HUNG WINDOWS. INFORMATION SUBMITTED IS | | | INCOMPLETE. NEED TO PROVIDE COMPLETE FLORIDA PRODUCT | | | APPROVAL (2 COPIES), INCLUDING THE FLORIDA PRODUCT | | | APPROVAL COVER PAGE THAT CORRESPONDS TO THE DRAWINGS | | | SUBMITTED. THE FLORIDA PRODUCT APPROVAL IS REQUIRED | | | BECAUSE IT SHOWS IF PRODUCT IS APPROVED AND CURRENT | | | CODE IN EFFECT. | | | | | | 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. REVISE AS REQUIRED OR PROVIDE COPY OF | | | SIGNED CONTRACTS INCLUDING THE DESIGN PROFESSIONAL | | | FEES. | | | | | | 7- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR | | | REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2019-12-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-22 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-22 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2019-08-12 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-08-12 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-08-12 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2019-08-12 12:41:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | (LOAD CALCULATION PROVIDED BY CONTRACTOR IS NOT SHOWN | | | ON PLAN. THE LOAD CALCULATION IS NOT SIGNED BY THE | | | PERSON RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 (NOT PROVIDED.) | | | 12.PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE NEXT | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | AGAIN FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW | | | IS REQUIRED. FLORIDA STATUTES STATE: WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B) | | | BASED ON THE CURRENT VALUE, THE ADDITIONAL FEE FOR THIS | | | PROJECT WOULD BE $ 829.12 | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-07-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-25 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-25 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2019-07-25 11:13:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | (LOAD CALCULATION PROVIDED BY CONTRACTOR IS NOT SHOWN | | | ON PLAN. THE LOAD CALCULATION IS NOT SIGNED BY THE | | | PERSON RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 (NOT PROVIDED.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-05-28 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-05-28 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2019-05-28 13:18:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM STATES THAT IT IS A TYPICAL DIAGRAM. | | | IS THIS RISER EXISTING, OR PROPOSED? THE PLAN IS NOT | | | CLEAR. PROVIDE CORRECTION. WPB FBC 107.2.1 | | | 2. OK | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 4. OK | | | 5. OK | | | 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | 7. OK | | | 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 9. OK | | | 10. OK | | | 11. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-01 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-01 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2019-05-28 13:16:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM STATES THAT IT IS A TYPICAL DIAGRAM. | | | IS THIS RISER EXISTING, OR PROPOSED? THE PLAN IS NOT | | | CLEAR. PROVIDE CORRECTION. WPB FBC 107.2.1 | | | 2. OK | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 4. OK | | | 5. OK | | | 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | 7. OK | | | 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 9. OK | | | 10. OK | | | 11. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | | | 2019-03-01 15:44:51 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM STATES THAT IT IS A TYPICAL DIAGRAM. | | | IS THIS RISER EXISTING, OR PROPOSED? THE PLAN IS NOT | | | CLEAR. PROVIDE CORRECTION. WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 4. IF SERVICE IS NEW, PROVIDE AVAILABLE SHORT CIRCUIT | | | CALCULATION FOR SERVICE INCLUDING INFORMATION FROM THE | | | POWER COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | | RATING OF THE SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, | | | 110.10; FBC RE E3606.3 | | | 5. PROVIDE LOCATION OF ELECTRICAL SERVICE AND PANEL(S) | | | ON PLAN. WPB FBC 107.2.1 | | | 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | 7. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 9. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE | | | CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | | 10. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | 11. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2020-07-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-07-10 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-07-10 |
Time |
11:00 |
Sent To |
I |
|
| Notes |
| 2020-07-10 11:01:34 | 07/10/2020 JOE DROPPED OFF THE ENERGY CALCULATIONS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-06-25 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-06-18 |
Time |
17:39 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-06 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-03 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-22 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-06 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-31 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-10 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-30 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-15 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-03-15 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-02-15 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-07-24 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-07-24 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2020-07-24 09:49:08 | $1693.14 PAID. MU-2020-026161. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-06-25 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-06-25 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2020-06-25 17:19:32 | IMPACT FEES - | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-12-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-12-10 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-12-10 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2019-12-10 08:56:45 | IMPACT FEES - | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-11 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-11 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2019-03-11 10:05:15 | IMPACT FEES - PAPER SUBMITTALS | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2020-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-06 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-06 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2020-01-06 15:37:05 | ADDRESS BUILDING REVIEW COMMENTS. CT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-22 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-08-22 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2019-08-22 13:56:29 | MECHANICAL PLAN PEVIEW FAIL | | | | | | | | | 1 - NEED ENERGY CALCULATIONS PER 2017 - FLORIDA | | | BUILDING CODE - ENERGY CONSERVATION SEC 101.5 | | | | | | 2 - NEED EQUIPMENT SIZING PER 2017 - FLORIDA BUILDING | | | CODE - ENERGY CONSERVATION SEC R403.7.1 EQUIPMENT | | | SIZING | | | | | | | | | PER RESPONSE LETTER CONTRACTOR TO PROVID, THIS IS STILL | | | REQUIRED PRIOR TO PERMIT BEING ISSUED | | | | | | | | | | | | CHRIS MONTELLO | | | 805-6733 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-07-22 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-07-22 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2019-07-22 11:44:35 | MECHANICAL PLAN REVIEW FAILED | | | | | | MECHANICAL PLAN PEVIEW FAIL | | | | | | | | | 1 - NEED ENERGY CALCULATIONS PER 2017 - FLORIDA | | | BUILDING CODE - ENERGY CONSERVATION SEC 101.5 | | | | | | 2 - NEED EQUIPMENT SIZING PER 2017 - FLORIDA BUILDING | | | CODE - ENERGY CONSERVATION SEC R403.7.1 EQUIPMENT | | | SIZING | | | | | | | | | PER RESPONSE LETTER CONTRACTOR TO PROVID, THIS IS STILL | | | REQUIRED PRIOR TO PERMIT BEING ISSUED | | | | | | | | | | | | CHRIS MONTELLO | | | 805-6733 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-05-28 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-05-28 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2019-05-28 14:48:22 | MECHANICAL PLAN PEVIEW FAIL | | | | | | | | | 1 - NEED ENERGY CALCULATIONS PER 2017 - FLORIDA | | | BUILDING CODE - ENERGY CONSERVATION SEC 101.5 | | | | | | 2 - NEED EQUIPMENT SIZING PER 2017 - FLORIDA BUILDING | | | CODE - ENERGY CONSERVATION SEC R403.7.1 EQUIPMENT | | | SIZING | | | | | | | | | | | | CHRIS MONTELLO | | | 805-6733 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-03-13 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-03-13 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2019-03-13 11:03:25 | PLAN DENIED | | | NO AIR CONDITIONING PLAN SUBMITTED. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-20 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-20 16:24:37 | PLUMBING COMMEMTS: APPROVED | | | PREVIOUSLY APPROVED BY GJOHNSON 7/19/19 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-07-19 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-07-19 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-05-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-17 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-17 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2019-05-17 13:26:15 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P-1 DETAIL #4 THE SHOWER PAN LINNING SHALL BE | | | PITCHED TO DRAIN A 1/4 PER FOT , 2% THE DETAIL SHOWS IT | | | AS FLAT. PLEASE SHOW COMPLIANCE . PER FBC RES P2709.3 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-03-07 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-03-07 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2019-03-07 12:58:20 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: DENIED | | | PLUMBING COMMENTS: | | | 1. BASED UPON A PERMIT RECORDS SEARCH, THE FOLLOWING | | | CONDITIONS EXIST; | | | A. THE EXISTING STRUCTURE WAS CONSTRUCTED UNDER PERMIT | | | #04070675 WHICH WAS TO ENCLOSE AN EXISTING CARPORT FOR | | | THE PURPOSE OF A ONE CAR GARAGE INCORPORATING THE | | | EXISTING WASHER AND DRYER INTO THE STRUCTURE AS WELL. | | | THE PERMIT STATUS IS EXPIRED. THAT PERMIT SHALL BE | | | REAPPLIED FOR AND ALL REQUIRED INSPECTION SHALL BE MADE | | | PRIOR TO ISSUANCE OF ANY NEW PERMITS. | | | B. EXISTING BATHROOM IS A NON-PERMITTED ADDITION; THE | | | EXISTING LAUNDRY HAS BEEN RELOCATED FROM THE PREVIOUS | | | PERMITTED RENOVATION. AN APPLICATION FOR PERMIT OR A | | | REVISION IS REQUIRED FOR THESE CHANGES OVER AND ABOVE | | | WHAT IS NOTED ON THE PERMIT #04070675 PLANS. | | | C. ADDITIONAL FEES WILL BE REQUIRED IN ACCORDANCE AS | | | SPELLED OUT IN WPB FBC 109. | | | END OF PLUMBING COMMENTS | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-08-09 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-07-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-07-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-07-17 17:02:09 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SURVEY OF THE PROPERTY IS MISSING FROM THE PERMIT | | | APPLICATION. PLEASE PROVIDE AN UPDATED, SIGNED AND | | | SEALED SURVEY OF THE PROPERTY. [3/15/19 AND 5/23/19 | | | REPEAT COMMENT] | | | | | | 2.) SITE PLAN NOTES THAT THE SCOPE OF WORK IS THE | | | ENCLOSURE OF AN EXISTING CARPORT; HOWEVER, STREET VIEW | | | OF THE PROPERTY SEEMS TO INDICATE THAT IT IS AN | | | EXISTING ATTACHED GARAGE. PLEASE CLARIFY. ALSO NOTE | | | THAT A CARPORT CANNOT BE ENCLOSED IF IT DOES NOT MEET | | | THE MINIMUM FRONT SETBACK OF 25 FT. FOR THE SF7 ZONING | | | DISTRICT. | | | | | | 3.) BUILDING ELEVATIONS ARE MISSING FROM THE PERMIT | | | APPLICATION. | | | | | | | | | NOTES: | | | | | | * SCOPE OF WORK ($14,455.00) DOES NOT EXCEED 50% VALUE | | | OF THE STRUCTURE PER 2018 PAPA IMPROVEMENT VALUE | | | ($84,174.00). | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-05-23 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-05-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-23 16:32:03 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: [COMMENTS FROM 3/15/19 HAVE NOT BEEN | | | ADDRESSED] | | | | | | 1.) SURVEY OF THE PROPERTY IS MISSING FROM THE PERMIT | | | APPLICATION. PLEASE PROVIDE AN UPDATED, SIGNED AND | | | SEALED SURVEY OF THE PROPERTY. | | | | | | 2.) PROVIDE A SITE PLAN OF THE PROPERTY, SHOWING THE | | | LOCATION OF THE SCOPE OF WORK (INCLUDING NEW | | | MECHANICAL/ELECTRICAL EQUIPMENT TO BE PLACED ON THE | | | EXTERIOR). INCLUDE ALL SETBACK DIMENSIONS FROM THE | | | (NEW) BUILDING ELEMENTS TO THE PROPERTY LINE. | | | | | | | | | NOTES: | | | | | | * SCOPE OF WORK ($14,455.00) DOES NOT EXCEED 50% VALUE | | | OF THE STRUCTURE PER 2018 PAPA IMPROVEMENT VALUE | | | ($84,174.00). | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-03-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-03-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-03-15 09:41:09 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SURVEY OF THE PROPERTY IS MISSING FROM THE PERMIT | | | APPLICATION. PLEASE PROVIDE AN UPDATED, SIGNED AND | | | SEALED SURVEY OF THE PROPERTY. | | | | | | 2.) PROVIDE A SITE PLAN OF THE PROPERTY, SHOWING THE | | | LOCATION OF THE SCOPE OF WORK (INCLUDING NEW | | | MECHANICAL/ELECTRICAL EQUIPMENT TO BE PLACED ON THE | | | EXTERIOR). INCLUDE ALL SETBACK DIMENSIONS FROM THE | | | (NEW) BUILDING ELEMENTS TO THE PROPERTY LINE. | | | | | | | | | NOTES: | | | | | | * SCOPE OF WORK ($14,455.00) DOES NOT EXCEED 50% VALUE | | | OF THE STRUCTURE PER 2018 PAPA IMPROVEMENT VALUE | | | ($84,174.00). | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | | | | |
|
|
|