| Plan Review Stops For Permit 19020653 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-09-10 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-09-10 |
Time |
08:15 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-08-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-08-13 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-08-13 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2019-08-13 08:42:35 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 1 FBC B 107.2.1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE | | | FOLLOWING INFORMATION: ACCESSIBLE ROUTE FROM PUBLIC WAY | | | TO THE PROPOSED RESTAURANT. | | | 2. FBC A 502.3. WHERE THE ACCESSIBLE ROUTE MUST CROSS | | | VEHICULAR TRAFFIC LANES, MARKED CROSSINGS ENHANCE | | | PEDESTRIAN SAFETY; PLEASE INDICATE LOCATION ON PLAN. | | | 3. FBC A 208.2.1. THE FOLLOWING USES HAVE ADDITIONAL | | | PARKING REQUIREMENTS: HOSPITAL OUTPATIENT FACILITIES; | | | REHABILITATION FACILITIES; OUTPATIENT PHYSICAL THERAPY | | | FACILITIES. PLAN IS TO EITHER SHOW LOCATION OF TENANTS | | | WITH ANY OF THE ABOVE USES OR PLAN IS TO INCLUDE A | | | STATEMENT WHICH STATES THAT NONE OF THE ABOVE USES | | | (HOSPITAL OUTPATIENT FACILITIES, REHABILITATION | | | FACILITIES, OUTPATIENT PHYSICAL THERAPY FACILITIES) ARE | | | AT THIS LOCATION. | | | 4. FBC B 107.1. THE INDIVIDUAL TAKING RESPONSIBILITY | | | SHALL PROVIDE THEIR PRINTED NAME AND SIGNATURE ON THE | | | PLAN. SITE PLAN NOT SIGNED. | | | 5.FBC B 107.1 IF THE DESIGN PROFESSIONAL IS AN | | | ARCHITECT, INTERIOR DESIGNER, OR ENGINEER LEGALLY | | | REGISTERED UNDER THE LAWS OF THE STATE OF FLORIDA | | | REGULATING THE PRACTICE OF ARCHITECTURE OR INTERIOR | | | DESIGN AS PROVIDED FOR IN CHAPTER 481, FLORIDA | | | STATUTES, PART I, OR LANDSCAPE ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, PART II, OR | | | ENGINEERING AS PROVIDED FOR IN CHAPTER 471, FLORIDA | | | STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE. SITE | | | PLAN NOT SIGNED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-08-01 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-08-01 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2019-08-01 12:18:38 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.FBC B 107.2.1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE | | | FOLLOWING INFORMATION: TOTAL NUMBER OF PARKING SPACES; | | | NUMBER OF ACCESSIBLE SPACES; LOCATION OF ACCESSIBLE | | | ENTRANCES; SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY; | | | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE | | | ENTRANCE. | | | 2.FBC A 502.3. WHERE THE ACCESSIBLE ROUTE MUST CROSS | | | VEHICULAR TRAFFIC LANES, MARKED CROSSINGS ENHANCE | | | PEDESTRIAN SAFETY; PLEASE INDICATE LOCATION ON PLAN. | | | 3. FBC A 208.2.1. THE FOLLOWING USES HAVE ADDITIONAL | | | PARKING REQUIREMENTS: HOSPITAL OUTPATIENT FACILITIES; | | | REHABILITATION FACILITIES; OUTPATIENT PHYSICAL THERAPY | | | FACILITIES. PLAN IS TO EITHER SHOW LOCATION OF TENANTS | | | WITH ANY OF THE ABOVE USES OR PLAN IS TO INCLUDE A | | | STATEMENT WHICH STATES THAT NONE OF THE ABOVE USES | | | (HOSPITAL OUTPATIENT FACILITIES, REHABILITATION | | | FACILITIES, OUTPATIENT PHYSICAL THERAPY FACILITIES) ARE | | | AT THIS LOCATION. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-03-29 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-29 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-29 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-08-02 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-07-31 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-03-28 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2019-03-28 |
Time |
|
Sent To |
B |
|
| Notes |
| 2019-03-28 07:24:21 | PASSED WITH PROVISO: | | | | | | THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS | | | PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES, | | | YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL | | | BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR | | | DEMOLITION WORK. MORE INFORMATION CAN BE FOUND HERE: | | | HTTP://WWW.SUNSHINE811.COM/ | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-09-10 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-08-29 |
Time |
10:38 |
Sent To |
B |
|
| Notes |
| 2019-08-29 16:24:03 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-08-13 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-08-07 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2019-08-08 14:20:21 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-08-01 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-07-26 |
Time |
14:56 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-29 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-03-28 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-14 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2019-02-14 16:39:48 | ROUTED TO ZONING INBOX | | | **TRAVELLING TOGETHER 19020653 & 19020656** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-09-18 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-09-18 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-09-18 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-08-09 |
Time |
10:25 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2019-08-09 |
Time |
09:54 |
Sent To |
B |
|
| Notes |
| 2019-08-09 10:25:19 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS: | | | | | | 1) REPEAT COMMENT: PROVIDE TWO COPIES OF A RECENT | | | SURVEY, LESS THAN ONE YEAR OLD. | | | | | | 2) THE PARKING TABLE PROVIDED ON SHEET SP IS INCORRECT. | | | A. THE ORIGINAL PARKING LOT FOR 1600 N. DIXIE HIGHWAY | | | HAD 28 PARKING SPACES, SO THE REQUIRED PARKING FOR 1600 | | | N. DIXIE HIGHWAY IS 28 PARKING SPACES. 28 PARKING | | | SPACES ARE PROVIDED. THE PARKING TABLE NEEDS TO STATE | | | IT THAT WAY. | | | B. THE 28 PARKING SPACES REQUIRE TWO ADA SPACES - TWO | | | PROVIDED. | | | C. THE 28 PARKING SPACES REQUIRE TWO BICYCLE PARKING | | | SPACES - TWO PROVIDED. | | | D. NO STREET PARKING MAY BE SHOWN ON THIS PLAN AS IT | | | HAS NOT BEEN APPROVED BY THE CITY'S ENGINEERING | | | SERVICES DEPARTMENT AND THE PLANS DO NOT SHOW CITY CODE | | | COMPLIANT STRIPING ON STREET PARKING. | | | E. THE BUILDING SQUARE FOOTAGE AND PARKING FOR 1522 N. | | | DIXIE HIGHWAY IS NOT PART OF THE PERMIT OR REQUIREMENTS | | | FOR 1600 N. DIXIE HIGHWAY, SO IT NEEDS TO BE REMOVED | | | FROM THE PLANS SUBMITTED WITH THIS PERMIT. | | | | | | SEPARATE PERMITS REQUIRED FOR: | | | | | | BICYCLE RACK | | | DUMPSTER ENCLOSURE (19020656) | | | | | | NOTE: THE 22 FOOT WIDE DRIVE AISLE IS A GRANDFATHERED | | | CONDITION. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-08-01 |
Time |
12:19 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-08-02 |
Time |
09:04 |
Sent To |
PC |
|
| Notes |
| 2019-08-02 10:12:16 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS: | | | | | | 1) REPEAT COMMENT: PROVIDE TWO COPIES OF A RECENT | | | SURVEY, LESS THAN ONE YEAR OLD. | | | | | | 2) REPEAT COMMENT: THE BICYCLE RACK PAD NEEDS TO BE | | | CONSTRUCTED OF CONCRETE, NOT ASPHALT. THE CONCRETE PAD | | | NEEDS TO BE AT THE SAME ELEVATION AS THE PARKING LOT SO | | | THE BICYCLE PARKING USERS DO NOT NEED TO LIFT THE | | | BICYCLE OVER A CURB. | | | | | | 3) REPEAT COMMENT: THE BICYCLE RACK REQUIRES A SEPARATE | | | PERMIT. PROVIDE BICYCLE RACK AND PAD DETAILS, INCLUDING | | | DIMENSIONS ON THE PLAN. NOTE: THE MIDDLE OF THE BICYCLE | | | RACK (EAST/WEST) NEEDS TO BE LOCATED THREE (3) FEET | | | FROM THE EASTERN EDGE OF THE NINE (9) FOOT CONCRETE | | | AREA SHOWN FOR THE BICYCLE RACK TO AVOID CONFLICTS WITH | | | THE DOOR. THE RACK ALSO NEEDS TO BE CENTERED WITHIN THE | | | NORTH/SOUTH EDGES OF THE BICYCLE PAD. THE RACK LOCATION | | | AND DIMENSIONS NEED TO BE UPDATED ON THE SITE PLAN. | | | | | | NOTE: THE 22 FOOT WIDE DRIVE AISLE IS A GRANDFATHERED | | | CONDITION. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-03-27 |
Time |
10:30 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2019-03-27 |
Time |
10:30 |
Sent To |
ENG |
|
| Notes |
| 2019-03-27 10:31:16 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS: | | | | | | 1) PROVIDE TWO COPIES OF A RECENT SURVEY, LESS THAN ONE | | | YEAR OLD. | | | | | | 2) THE LANDSCAPE ISLANDS, WHERE THEY ARE ADJACENT TO | | | THE SIDEWALK, NEED TO EXTEND PERPENDICULAR TO THE | | | SIDEWALK NOT CURVED. THE ISLANDS ARE NOT PART OF THE | | | DRIVEWAY APPROACH. | | | | | | 3) THE PARKING LOT DOES NOT CONFORM TO THE CITY'S | | | PARKING LOT LANDSCAPE REQUIREMENTS. PLEASE REFER TO | | | PERMIT NO. 17071228. | | | | | | 4) THE AREA ON THE SOUTH SIDE OF THE MIDDLE ROW OF | | | PARKING SPACES IS REQUIRED TO BE A TERMINAL LANDSCAPE | | | ISLAND, NOT PAINTED PAVEMENT. THIS LANDSCAPE AREA MUST | | | BE PROTECTED FROM VEHICULAR ENCROACHMENT WITH A D CURB. | | | | | | 5) THE AREA ADJACENT TO THE SOUTHEAST PORTION OF THE | | | BUILDING IS REQUIRED TO BE A FOUNDATION LANDSCAPE AREA | | | SINCE THE BUILDING IS CURRENTLY DEFICIENT IN MEETING | | | THE REQUIRED MINIMUM 30% FOUNDATION PLANTING. THIS | | | LANDSCAPE AREA MUST BE PROTECTED FROM VEHICULAR | | | ENCROACHMENT WITH A D CURB. | | | | | | 6) THE PARKING DETAIL INCLUDED ON SHEET 2 DOES NOT | | | COMPLY WITH CITY OF WEST PALM BEACH STANDARDS. USE THE | | | CITY STANDARD DETAIL. IT IS AVAILABLE FROM THE PLANNING | | | DIVISION. | | | | | | 7) THE 22 FOOT WIDE DRIVE AISLE IS A GRANDFATHERED | | | CONDITION. | | | | | | 8) THE BICYCLE PARKING LOCATION DOES NOT MEET THE | | | CITY'S LOCATION REQUIREMENTS: | | | | | | A. LOCATED IN CONVENIENT, HIGHLY-VISIBLE, ACTIVE, | | | WELL-LIGHTED AREAS. | | | B. LOCATED AS NEAR THE PRINCIPAL ENTRANCE OF THE | | | BUILDING AS PRACTICABLE. | | | C. STAFF SUGGESTS LOCATING THE BICYCLE RACK NEAR THE | | | SOUTHEASTERN DOOR INSTEAD OF THE STRIPED OUT AREA. THE | | | PAD NEEDS TO BE CONSTRUCTED OF CONCRETE, NOT ASPHALT, | | | AT THIS LOCATION TO PROVIDE A VISUAL DIFFERENCE FROM | | | THE DRIVE AISLE. PLEASE CONTACT STAFF TO DISCUSS THE | | | PARTICULARS OF PLACEMENT IN THIS AREA. | | | | | | 9) THE BICYCLE RACK REQUIRES A SEPARATE PERMIT. PROVIDE | | | BICYCLE RACK AND PAD DETAILS, INCLUDING DIMENSIONS ON | | | THE PLAN. ADDITIONALLY, THE DIMENSIONS OF THE BICYCLE | | | PAD NEED TO BE SHOWN ON THE SITE PLAN. PLEASE NOTE THAT | | | ONLY ONE RACK IS REQUIRED (HAS TWO PARKING SPACES). | | | | | | 10) STAFF SUGGESTS REVIEWING THE OPTION OF REMOVING THE | | | POWER POLES AND BURYING THE UTILITY LINES AS THIS WILL | | | NOT ONLY IMPROVE THE AESTHETICS OF THE SITE, BUT IT | | | WILL ALSO ALLOW MORE FLEXIBILITY IN THE SITE DESIGN AS | | | IT RELATES TO THE SOUTH PROPERTY LINE. ANOTHER OPTION | | | MAY BE TO CONSOLIDATE THE SERVICES ON ONE POLE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|