| 2019-03-12 14:05:42 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 19020586 |
| | REVIEWED: MARCH 12, 2019 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER PX4191 |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) |
| | FBC[A] = FBC ACCESSIBILITY |
| | FBC[E] = FBC ENERGY CONSERVATION |
| | FBC[R] = FBC RESIDENTIAL |
| | |
| | 1) 109.3 FBC[AMENDED] PROVIDE COPY OF PROPOSAL WITH |
| | CONTRACTOR TO SHOW WORK VALUE EQUAL TO THE AMOUNT SHOWN |
| | ON PERMIT APPLICATION, OR ADJUST VALUE TO MATCH ACTUAL |
| | COST OF WORK. PLEASE ADJUST FEE AT FRONT DESK AND PAY |
| | ADJUSTED PERMIT REVIEW FEE AT TIME OF RE-SUBMITTAL. |
| | -VALUE WAS CHECKED AGAINST CURRENT ICC BUILDING |
| | VALUATION DATA AND THE PROPOSED VALUE APPEARS LOW. |
| | PLEASE PROVIDE COST ESTIMATE, OR CALL/E-MAIL TO DISCUSS |
| | THE VALUATION OF CONSTRUCTION. |
| | |
| | 2)103.1.1.2 FBC[RE] THE BUILDINGS OWNER, THE OWNERS |
| | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNATED |
| | BY THE OWNER SHALL CERTIFY THAT THE BUILDING IS IN |
| | COMPLIANCE WITH THE CODE, AS PER SECTION 553.907, |
| | FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO |
| | BEGIN CONSTRUCTION OR RENOVATION. 553.907, FLORIDA |
| | STATUTES. |
| | -PLEASE HAVE THE OWNER SIGN THE ENERGY CALCULATIONS. |
| | |
| | 3) 107.3.5 FBC[R] THE ENERGY CALCS SHOWS CEILING TYPE |
| | UNDER ATTIC AT 1859 SQ, FT. (VENTED) 1859 SQ. FT. IS |
| | THE TOTAL AREA UNDER AIR ACCORDING TO SHEET NUMBER 3 OF |
| | 9. SINCE THIS IS TWO STORY AND THE SPACE BETWEEN FLOORS |
| | ISNT VENTED, ATTIC (VENTED) SHOULD ONLY INCLUDE SECOND |
| | FLOOR ATTIC SPACE. THE ATTIC AREA IS PROVIDED ON SHEET |
| | 5 OF 9. PLEASE ADJUST ENERGY CALCULATIONS AS NEEDED. |
| | -ALSO, THE PLANS ARE CALLING FOR BATTS AND THE ENERGY |
| | CALCULATIONS ARE BASED ON BLOWN IN. |
| | |
| | 4) 301.4 FBC[R] DEAD LOAD. THE ACTUAL WEIGHTS OF |
| | MATERIALS AND CONSTRUCTION SHALL BE USED FOR |
| | DETERMINING DEAD LOAD WITH CONSIDERATION FOR THE DEAD |
| | LOAD OF FIXED SERVICE EQUIPMENT. |
| | -PLEASE PROVIDE LIVE AND DEAD LOADS TO DESIGN DATA FOR |
| | ROOF, ATTIC AND FLOORS. |
| | |
| | 5) 311.2 FBC[R] NOT LESS THAN ONE EGRESS DOOR SHALL BE |
| | PROVIDED FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL |
| | BE SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT |
| | LESS THAN 32 INCHES WHERE MEASURED BETWEEN THE FACE OF |
| | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. |
| | THE CLEAR HEIGHT OF THE DOOR OPENING SHALL BE NOT LESS |
| | THAN 78 INCHES IN HEIGHT MEASURED FROM THE TOP OF THE |
| | THRESHOLD TO THE BOTTOM OF THE STOP. OTHER DOORS SHALL |
| | NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM |
| | DIMENSIONS. EGRESS DOORS SHALL BE READILY OPENABLE FROM |
| | INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL |
| | KNOWLEDGE OR EFFORT. |
| | -CHECK CLEAR SPACE AT ENTRY DOOR SINCE IT CAN'T SWING |
| | ALL THE WAY OPEN. |
| | |
| | 6) 302.5.3 FBC[R] OTHER PENETRATIONS. PENETRATIONS |
| | THROUGH THE SEPARATION REQUIRED IN SECTION R302.6 SHALL |
| | BE PROTECTED AS REQUIRED BY SECTION R302.11, ITEM 4. |
| | -DRYWALL IN GARAGE WITH HABITABLE ROOM ABOVE NEED TO |
| | USE NOT LESS THAN 5/8 TYPE X GYPSUM OR EQUIVALENT. SEE |
| | TABLE 302.6 AND ADD NOTE IN PLANS. |
| | |
| | 7) 107.3.5.3 FBC[AMENDED] PROVIDE SEDIMENT CONTROL TO |
| | KEEP CONSTRUCTION DEBRIS FROM ENTERING ADJACENT |
| | PROPERTIES AND STORM DRAINS DURING CONSTRUCTION. YOU |
| | CAN JUST ADD SILT FENCE DETAIL AND HOW DRAINS ARE |
| | PROTECTED TO THE DRAINAGE PLAN. SOME ENGINEERING |
| | STANDARD DETAILS CAN BE USED FROM WPB WEBSITE-POLLUTION |
| | CONTROL. HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUB |
| | LIC-WORKS/FORMS,-PERMITS-APPLICATIONS |
| | |
| | 8) [FBC 107.5][FBC 110.9][FBC R401.3][PROVIDE SITE |
| | DRAINAGE PLAN. SURFACE DRAINAGE SHALL BE DIVERTED TO A |
| | STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF |
| | COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE |
| | GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION |
| | WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES |
| | WITHIN THE FIRST 10 FEET. EXCEPTION: WHERE LOT LINES, |
| | WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6 |
| | INCHES OF FALL WITHIN 10 FEET (3048 MM), DRAINS OR |
| | SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY |
| | FROM THE STRUCTURE. IMPERVIOUS SURFACES WITHIN 10 FEET |
| | OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF |
| | 2 PERCENT AWAY FROM THE BUILDING. |
| | |
| | 9) 703.4 FBC[R] PROVIDE TYPE OF WINDOW/DOOR FLASHING TO |
| | BE USED TO MEET REQUIREMENTS OF R703.4 |
| | |
| | 10) 301.6 FBC[R] ROOF LOAD. THE ROOF SHALL BE DESIGNED |
| | FOR THE LIVE LOAD INDICATED IN TABLE R301.6 |
| | |
| | 11) 107.3.4.1 FBC[AMENDED] PRODUCT APPROVAL. |
| | -PRODUCT APPROVAL FOR FIBERGLASS DOOR IS FL-15225.5 |
| | AND THE TABLE ON SHEET 4 OF 9 AND 12 OF 9 HAS |
| | CONFLICTING PRODUCT APPROVAL NUMBER. PLEASE ADJUST LIST |
| | TO MATCH PROVIDED, OR REMOVE THE TABLE ON SHEET 4 OF 9 |
| | |
| | 12) 107.3.5 FBC[R] THE WINDOW MULL (HORIZONTAL AND |
| | VERTICAL), SINGLE HUNG, SLIDING DOOR AND FIXED WINDOW. |
| | THERE ARE NO EVALUATION REPORTS ON THESE PRODUCT |
| | APPROVALS AND THEY DON'T MATCH THE NUMBERS PROVIDED ON |
| | SHEET 4 OF 9 AND 1 OF 9. |
| | -PLEASE PROVIDE THE EVALUATION REPORTS FOR THESE AND |
| | PUT THE CURRENT PRODUCT APPROVAL ON THEM BECAUSE THE |
| | INSTALLATION INSTRUCTIONS PROVIDED ONLY HAVE OLD |
| | DRAWING NUMBERS AND DO NOT REFERENCE CURRENT NUMBERS. |
| | |
| | 13) 107.3.4.1 FBC[AMENDED] SUBMIT TRUSS SHOP DRAWINGS |
| | TO THE BUILDING INSPECTOR PRIOR TO INSTALLATION. |
| | -THIS WILL BE A DEFERRED SUBMITTAL. THE TRUSS PACKAGE |
| | NEEDS TO BE REVIEWED BY BUILDING INSPECTOR PRIOR TO |
| | INSTALLATION. |
| | |
| | 14) 107.2.1.2 FBC[AMENDED] PROVIDE STAIRCASE AND GUARD |
| | RAIL ENGINEERING, OR INDICATE THAT IT WILL BE |
| | DEFERRED. |
| | |
| | NOTES: |
| | |
| | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| | EACH COMMENT IS BEING ADDRESSED. |
| | |
| | -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS. |
| | FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE |
| | REQUIRED. |
| | |
| | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| | OF MATERIALS REQUESTED. |
| | |
| | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| | NEED "VOID", RENDERING THEM NOT USABLE. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F |
| | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME |
| | [email protected] |
| | |
| | |
| | |