| 2019-02-24 13:54:36 | 1) THE DESCRIPTION OF WORK ON THE APPLICATION |
| | STATES"EXACT CHANGE OUT FOR BATHROOM". EXACT CHANGEOUT |
| | OF WHAT? THE PLANS ARE SO VAGUE A COMPREHENSIVE REVIEW |
| | COULD NOT BE PERFORMED. CLEARLY INDICATE ON THE PLANS |
| | AND THE PERMIT APPLICATION THE ENTIRE SCOPE OF WORK TO |
| | BE PERFORMED. WPB AMEND. TO FBC SEC. 107.2.1. |
| | 2) SUBMIT TWO COPIES OF AN EXISTING FLOOR PLAN SHOWING |
| | THE PRESENT LAYOUT AND PLUMBING FIXTURES. WPB AMEND. TO |
| | FBC SEC. 107.2.1. |
| | 3) INDICATE ON THE PLANS IF ANY NEW FLOORING IS BEING |
| | INSTALLED. IF SO, SHOW THE TYPE OF FLOORING TO BE |
| | INSTALLED. WPB AMEND. TO FBC SEC. 107.2.1. |
| | 4) IF NEW FLOORING IS TO BE INSTALLED, SUBMIT TWO |
| | COPIES OF THE MANUFACTURER'S SPECIFICATIONS FOR THE |
| | UNDERLAYMENT MATERIAL.WPB AMEND. TO FBC SEC. 107.2.1. |
| | THE UNDERLAYMENT SHALL MEET THE FOLLOWING CRITERIA: |
| | |
| | FBC-B 2017 SEC.1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492?09. |
| | |
| | 1B) FBC-B 2017 SEC.1207.2 - AIR-BORNE SOUND. |
| | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90-04. |
| | |
| | 2) FLAME SPREAD- FBC-B 2017 SEC. 603.1(2) EXCEPTION 2. |
| | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| | |
| | 2017 FBC SEC.720.2 - CONCEALED INSTALLATION. |
| | INSULATING MATERIALS, WHERE CONCEALED AS INSTALLED IN |
| | BUILDINGS OF ANY TYPE OF CONSTRUCTION, SHALL HAVE A |
| | FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A |
| | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450. |
| | |
| | |
| | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| | |
| | 2017 FBC SEC.703.5 - NONCOMBUSTIBILITY TESTS. |
| | THE TESTS INDICATED IN SECTIONS 703.5.1 AND 703.5.2 |
| | SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING |
| | MATERIALS AS SET FORTH IN SECTIONS 602.2, 602.3 AND |
| | 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM |
| | ?NONCOMBUSTIBLE? DOES NOT APPLY TO THE FLAME SPREAD |
| | CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A |
| | MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE |
| | BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN |
| | INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE |
| | LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF |
| | AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS. |
| | |
| | 2017 FBC SEC. 703.5.1 ELEMENTARY MATERIALS. |
| | MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED |
| | IN ACCORDANCE WITH ASTM E 136. |
| | |
| | 2017 FBC SEC. 703.5.2 COMPOSITE MATERIALS. |
| | MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE |
| | MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION |
| | 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18 |
| | MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER |
| | THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL |
| | 723 SHALL BE ACCEPTABLE AS |
| | NONCOMBUSTIBLE MATERIALS. |
| | |
| | 5) SUBMIT TWO COPIES OF THE NONCOMBUSTIBILITY TESTS FOR |
| | REVIEW.WPB AMEND. TO FBC SEC. 107.2.1. |
| | |
| | 6) THIS WORK MUST BE DONE BY A LICENSED GENERAL |
| | CONTRACTOR OR BUILDING CONTRACTOR. A RESIDENTIAL |
| | CONTRACTOR CANNOT PERFORM THIS WORK PER FL. STATUTE |
| | 489.105. SUBMIT A NEW APPLICATION FROM A GENERAL OR |
| | BUILDING CONTRACTOR. |
| | |
| | 7) A SEPARATE PLUMBING PERMIT APPLICATION IS REQUIRED |
| | BY A LICENSED PLUMBING CONTRACTOR FOR THE PLUMBING |
| | WORK. |
| | |
| | NOTE: ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED |
| | AFTER CORRECTIONS ARE SUBMITTED. |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | PLUMBING PLAN REVIEW |
| | 561-805-6692 |
| | [email protected] |
| | |
| | |
| | |