| Plan Review Stops For Permit 19020469 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2019-05-08 14:41:38 | REDUCTION OF SCOPE OF WORK AND INDEPENDENT APPRAISAL | | | REMOVES THE REQUIREMENTS OF SUBSTANTIAL IMPROVEMENT. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-12 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2019-04-12 14:27:53 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. WINDOWS AND DOORS WILL BY SEPERATE PERMIT. REMOVE | | | PRODUCT APPROVALS FROM SUBMITTAL. | | | | | | 2. ELEVATION CERTIFICATE IS REQUIRED. SEE COMMENTS | | | UNDER NFIP REVIEW. | | | | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS | | | A WITH A BASE FLOOD ELEVATION (BFE) OF 6FT NAVD 88. THE | | | CITY OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN | | | ADDITIONAL 24 INCHES OF FREEBOARD REQUIRING THE DESIGN | | | FLOOD ELEVATION (DFE) TO BE 8. 0 FEET NAVD 88. PLEASE | | | NOTE THIS INFORMATION ON YOUR PLANS. | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS | | | SITE ARE REQUIRED TO BE AT OR ABOVE 8 FEET NAVD 88. | | | | | | AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED | | | FLOOR ELEVATION IS REQUIRED. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | THIS EC MAY BE SUBMITTED FOR REVIEW PRIOR TO BUILDING | | | FINAL. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-28 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-27 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2019-02-28 12:46:20 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | THE SCOPE OF WORK (SOW) IS FOR A SUBSTANTIAL | | | IMPROVEMENT TO THE PROPERTY CONSISTING OF A LEVEL III | | | ALTERATION PER THE FBC EXISTING BUILDINGS SECTION 505. | | | | | | 1. PROPERTY IS LOCATED WITHIN A SPECIAL FLOOD HAZARD | | | AREA (SFHA) WITH A BASE FLOOD ELEVATION (BFE) OF 6 FEET | | | NAVD 88. THE CITY OF WEST PALM BEACH, BY ORDINANCE, | | | REQUIRES A TWO FOOT FREEBOARD ABOVE THE BFE REQUIRING A | | | DESIGN FLOOD ELEVATION (DFE) OF 8 FEET NAVD 88. | | | A DESIGN PROFESSIONAL SHALL ESTABLISH THE CORRECT DFE | | | BASED ON THE CURRENT FLOOD INSURANCE STUDY(FIS). | | | | | | 2. THE VALUE OF THE PROPOSED WORK, $225,000.00 EXCEEDS | | | 50% OF THE MARKET VALUE OF THE STRUCTURE, $150,653.00 | | | REQUIRING YOU TO MEET THE THE SUBSTANTIAL IMPROVEMENTS | | | PROVISIONS OF THE CODE AND MAY REQUIRE ELEVATING THE | | | STRUCTURE TO BRING IT INTO COMPLIANCE. | | | | | | 3. YOU MAY EVALUATE THE STRUCTURE PER FEMA P758, DESK | | | REFERENCE CHAPTER 4 FOR COMPLIANCE WITH THE SUBSTANTIAL | | | IMPROVEMENTS PROVISION. (SEE LINK BELOW) | | | HTTPS://WWW.FEMA.GOV/MEDIA-LIBRARY/ASSETS/DOCUMENTS/185 | | | 62 | | | | | | 4. TYPE OF CONSTRUCTION PER THE FBC CHPT. 6 IS VB. | | | | | | 5. THE GOVERNING CODES ARE THE 2017 FBC 6TH ED W/2017 | | | WEST PALM BEACH AMENDMENTS. | | | | | | 6. WINDOW REPLACEMENT IS LISTED IN WORK DESCRIPTION ON | | | PERMIT APPLICATION. NOTE ON PLAN PAGE A-1 STATES | | | WINDOWS AND DOORS UNDER SEPERATE PERMIT. PLEASE | | | CLARIFY. | | | | | | 7. STRUCTURAL CALCULATIONS COVER PAGE INDICATES THERE | | | ARE 45 PAGES. THERE ARE ONLY 10 PAGES PROVIDED. PLEASE | | | CLARIFY. | | | | | | 8. PROVIDE INSTALLATION INSTRUCTIONS FOR THE FOLLOWING | | | PRODUCT APPROVALS: A. EXT. DOORS FL-251-R30. B. FIXED | | | WINDOWS FL243-R21. C. CASEMENT WINDOWS FL245-R12 AND D. | | | EXTERIOR DOORS FL253-R19. | | | | | | 9. DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL NOA'S AND PRODUCT APPROVALS. SELECT MODEL TO BE | | | INSTALLED. | | | | | | 10. PROVIDE DESIGN WIND LOADS FOR ALL WINDOW AND DOOR | | | OPENINGS. YOU MAY PLACE THESE ON THE PLANS OR WINDOW | | | AND DOOR SCHEDULE. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-04-10 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-04-10 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-04-10 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-26 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-26 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2019-02-26 12:34:13 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. ALL LOADS ARE NOT SHOWN IN CALCULATION | | | PROVIDED. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 2. SCOPE OF WORK STATES THAT MAIN DISCONNECT IS NEW, | | | BUT THE RISER SHOWS THIS AS EXISTING. PROVIDE | | | CLARIFICATION AND/OR CORRECTION. NEC 215.5; WPB FBC | | | 107.2.1 | | | 3. IF SERVICE IS BEING REPLACED OR RE-WORKED, PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION FOR SERVICE | | | INCLUDING INFORMATION FROM THE POWER COMPANY STATING | | | WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE | | | SERVICE TO CONFIRM THE STATED AIC RATING OF THE SERVICE | | | EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC RE | | | E3606.3 | | | 4. NOTE STATES THAT ALL REEPTACLES SHALL BE TAMPER | | | RESISTANT PER THE 2011 NEC, WHICH IS NOT THE CURRENT | | | CODE. PROVIDE CORRECTION. FBC PREFACE | | | 5. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 | | | 6. PANEL SCHEDULES SHOW ONE ASTERISK FOR ARC FAULT | | | CIRCUIT, AND THE SHOWS TWO ASTERISK FOR THE SAME THING. | | | WHICH IS IT? PROVIDE CLARIFICATION AND CORRECT | | | DISCREPANCY. | | | 7. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2019-05-08 14:43:53 | GAS REMOVED FROM SCOPE OF WORK. REMOVE GAS WATER HEATER | | | DURING REVISION SUBMITTAL OF PLAN PAGE E-1. SEE | | | PROVISO. CT |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-12 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2019-04-12 16:52:55 | GAS PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. REFERENCE PLAN PAGE P-1. RE-NAME PLUMBING CONNECTION | | | SCHEDULE TO GAS EQUIPMENT SCHEDULE. | | | | | | 2. LIST ALL GAS EQUIPMENT ON SCHEDULE. PLAN PAGE A-2 | | | SHOWS A GAS WATER HEATER. ARE THERE ANY MORE GAS | | | APPLIANCES? | | | | | | 3. STATE CORRECT GAS PIPING TABLE ON GAS PIPING | | | CALCULATION SCHEDULE. THIS IS A RESIDENTIAL PROPERTY, | | | TABLE SHOULD BE G2413.4 (1). | | | | | | 4. PROVIDE COMBUSTION AIR CALCULATIONS PER G2407.1. | | | | | | 5. PROVIDE VENTING DETAIL PER G2427. | | | | | | 6. SHUTOFF REQUIRED PRIOR TO GAS LINE ENTERING THE | | | BUILDING. | | | | | | 7. PROVIDE DRIPLEG DETAIL AT APPLIANCES PER G2419. | | | | | | 8. GASS RISER DIAGRAHM SHOWS TWO SHUTOFFS AT APPLIANCE | | | LOCATION. IS ONE OF THESE A REGULATOR? PLEASE CLARIFY. | | | | | | CANNOT VERIFY PIPING SIZE UNTIL TOTAL BTU LAOD AND | | | TOTAL PIPING LENGTH HAVE BEEN PROVIDED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-28 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-28 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-02-28 13:33:02 | GAS PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 2. GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | 3. GAS APPLIANCES SHALL BE LISTED AND LABELED PER | | | FBC-FUEL GAS SEC. 301.3. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-01 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2019-05-02 13:10:33 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-12 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-03 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-28 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-11 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-04-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-04-06 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-04-06 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-02-27 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-02-27 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2019-02-27 14:16:48 | MECHANICAL PLAN REVIEW FAIL | | | | | | | | | 1 - RETURN AIR FOR MASTER BEDROOM TO SMALL PER FBC. | | | SEC. M1602.3 BALANCED RETURN AIR. PER PLAN MASTER SUITE | | | HAS 250 CFM | | | | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
N |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2019-05-08 14:47:25 | REDUCTION OF SCOPE OF WORK AND INDEPENDENT APPRAISAL | | | REMOVES THE REQUIREMENT OF SUBSTANTIAL IMPROVEMENT. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2019-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-12 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2019-04-12 15:08:02 | NFIP REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THE SCOPE OF WORK (SOW) IS FOR A SUBSTANTIAL | | | IMPROVEMENT TO THE PROPERTY CONSISTING OF A LEVEL III | | | ALTERATION PER THE FBC EXISTING BUILDINGS SECTION 505. | | | | | | 1. THE PROPERTY IS LOCATED WITHIN A SPECIAL FLOOD | | | HAZARD AREA (SFHA) WITH A BASE FLOOD ELEVATION (BFE) OF | | | 6 FEET NAVD 88. THE CITY OF WEST PALM BEACH, BY | | | ORDINANCE, REQUIRES A TWO FOOT FREEBOARD ABOVE THE BFE | | | REQUIRING A DESIGN FLOOD ELEVATION (DFE) OF 8 FEET NAVD | | | 88. | | | A DESIGN PROFESSIONAL SHALL ESTABLISH THE CORRECT DFE | | | BASED ON THE CURRENT FLOOD INSURANCE STUDY (FIS). | | | | | | 2. THE VALUE OF THE PROPOSED WORK, $225,000.00 IN | | | ADDITION TO THE COST OF DEMOLITION $8000.00 FOR A TOTAL | | | VALUE OF 233,000.00, EXCEEDS 50% OF THE APPRAISED VALUE | | | OF THE STRUCTURE, $297,655.00, REQUIRING YOU TO MEET | | | THE THE SUBSTANTIAL IMPROVEMENTS PROVISIONS OF FEMA | | | REGULATIONS P-758, PUBLISHED MAY 2010 AND REQUIRES | | | ELEVATING THE STRUCTURE TO THE DESIGN FLOOD ELEVATION | | | (DFE) OF 8 FEET NAVD 88. | | | | | | NOTE 1: COPY OF APPRAISAL INCLUDED IN THIS SUBMITTAL. | | | NOTE 2: COST OF DEMOLITION ADDED TO VALUE BASED ON FEMA | | | REGULATIONS P-758, SECTION 4.4.6. | | | | | | 3. A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS | | | SITE ARE REQUIRED TO BE AT OR ABOVE 8 FEET NAVD 88. | | | | | | AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED | | | FLOOR ELEVATION IS REQUIRED. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | THIS EC MAY BE SUBMITTED FOR REVIEW PRIOR TO BUILDING | | | FINAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-08 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2019-05-08 14:45:11 | GAS REMOVED FROM SCOPE OF WORK. GAS WATER HEATER TO BE | | | REMOVED DURING REVISION SUBMITTAL OF PLAN PAGE E-1. SEE | | | PROVISO. CT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-12 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2019-04-12 15:37:33 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. LABEL ALL FIXTURES ON RISER DIAGRAHM. | | | 2. SHOW ALL TRAPS WHERE REQUIRED ON RISER DIAGRAHM. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-28 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-27 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2019-02-28 12:51:43 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1. SANITARY PLAN DOES NOT STATE IF IT'S EXISTING OR | | | PROPOSED. | | | 2. IF SANITARY IS NEW, PROVIDE RISER DIAGRAHM. | | | 3. IF CONCRETE SLAB IS TO BE CUT, PROVIDE REPAIR | | | DETAIL. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-02-27 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-27 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2019-02-27 17:14:09 | FIRST PLUMBING REVIEW WAS CLOSED BY MISTAKE. OPENED A | | | SECOND PLUMBING REVIEW. CT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
cdglass |
Date |
2019-04-11 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
cdglass |
Date |
2019-04-11 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2019-04-11 15:22:26 | ** PASSED ** | | | | | | COMMENTS: | | | THE VALUE OF THE RENOVATION ($225,000) EXCEEDS 50% OF | | | THE STRUCTURE'S VALUE ($297,665) ACCORDING TO THE | | | REVISED DOCUMENTS SENT VIA THE APPLICANT; THEREFORE, | | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. PROOF OF | | | LANDSCAPE CONFORMITY MUST BE PROVIDED PRIOR TO CO. IF | | | THE SITE DOES NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO | | | CO A SEPARATE LANDSCAPE PERMIT AND IRRIGRATION PERMIT | | | SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE SITE | | | INTO CONFORMITY. | | | | | | NOTES: | | | CONTACT CAROLINE GLASS, [email protected], (561) 822-1431 | | | WITH ANY ADDITIONAL QUESTIONS. | | | | | | ZONE: SF7 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
cdglass |
Date |
2019-02-15 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
cdglass |
Date |
2019-02-15 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2019-02-15 11:18:09 | ** PASSED ** | | | | | | COMMENTS: | | | THE VALUE OF THE RENOVATION ($225,000) EXCEEDS 50% OF | | | THE STRUCTURE'S VALUE ($150,653) ACCORDING TO THE PALM | | | BEACH COUNTY PROPERTY APPRAISER'S OFFICE; THEREFORE, | | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. PROOF OF | | | LANDSCAPE CONFORMITY MUST BE PROVIDED PRIOR TO CO. IF | | | THE SITE DOES NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO | | | CO A SEPARATE LANDSCAPE PERMIT AND IRRIGRATION PERMIT | | | SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE SITE | | | INTO CONFORMITY. | | | | | | NOTES: | | | CONTACT CAROLINE GLASS, [email protected], (561) 822-1431 | | | WITH ANY ADDITIONAL QUESTIONS. | | | | | | ZONE: SF7 |
|
|