| Plan Review Stops For Permit 19020363 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-27 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2019-12-23 08:51:12 | UPDATED FORM BOARD SURVEY DATED 12/22/2019. NO | | | ENCROACHMENT INTO FLOOD ZONE. NO NFIP REVIEW REQUIRED. | | | CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-09 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2019-08-09 10:24:55 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE ROUGH | | | OPENINGS AND DESIGN PRESSURES OF EACH OPENING. | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | R301.2.1 WIND DESIGN CRITERIA. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-08 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-07 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2019-03-08 12:21:34 | RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- PLANS SHOW EXISTING KITCHEN, FAMILY ROOM AND DINING | | | ROOM AREA. THIS AREA USED TO BE THE GARAGE AREA. THERE | | | ARE NO PERMITS SHOWING THAT CONVERSION WAS ALLOWED. | | | ALSO, PLANS SHOW THREE EXISTING BATHROOMS. ORIGINAL | | | HOUSE HAD ONLY ONE BATHROOM. THERE ARE NO PERMITS FOR | | | THE ADDITIONAL BATHROOMS. CLARIFY HOW CAN YOU HAVE | | | THREE BATHROOMS IF THERE IS ONLY ONE BEDROOM?. THERE IS | | | AN OPEN PERMIT APPLICATION ( PERMIT #18120043) THAT | | | INCLUDES WORK TO LEGALIZE CONVERSION OF GARAGE TO | | | LIVING AREA. THIS PERMIT HAVE NOT BEEN ISSUED AND IS | | | NOT CLEAR IF CONTRACTOR IS GOING TO ADDRESS THE | | | COMMENTS TO GET THAT PERMIT. SINCE CONTRACTOR FOR THAT | | | PERMIT IS THE SAME CONTRACTOR APPLYING FOR THE | | | ADDITION, THEN IT MAY BE POSSIBLE TO COMBINE THE TWO | | | PERMITS INTO THIS ONE. THIS WAY THAT PERMIT CAN BE | | | REVOKED AND THERE WILL BE NO OUTSTANDING PERMIT ON THIS | | | PROPERTY. CONTRACTOR TO ADVICE IF HE WANTS TO ADD THAT | | | SCOPE OF WORK TO THIS PERMIT. NOTE: PLANS NEED TO BE | | | CORRECTED ACCORDINGLY SHOWING ALL THE EXISTING | | | ALTERATIONS THAT WERE DONE WITHOUT PERMIT AS NEW AND | | | NOT AS EXISTING. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. 1106 FBC-EXISTING BUILDING. AND SEC. R101.4.2 | | | AND R101.5 FBC-ENERGY CONSERVATION. | | | | | | 3- PROVIDE SOIL TEST REPORT (2 COPIES) AS REQUIRED BY | | | SEC. R401.4 FBC-RESIDENTIAL. | | | | | | 4- ACCORDING TO NEW FEMA FLOOD MAPS MAPS EFFECTIVE | | | OCTOBER 5, 2017 THIS PROPERTY IS LOCATED IN FLOOD ZONE | | | AE. CURRENTLY, THE EXISTING BUILDING IS NOT TOUCHING | | | THE CONTOUR LINE OF THE FLOOD ZONE AE. BUT PROPOSED | | | ADDITION MAY BE TOUCHING THIS FLOOD ZONE AE. PROVIDE | | | CURRENT SURVEY (TWO COPIES)SHOWING THE PROPOSED | | | ADDITION AND LOCATION OF THE FLOOD ZONE AE CONTOUR LINE | | | TO VERIFY IF PROPOSED ADDITION AND EXISTING HOUSE NEED | | | TO COMPLY WITH CURRENT REQUIREMENTS FOR BUILDINGS | | | LOCATED IN FLOOD ZONES. NOTE: BUILDINGS ON FLOOD ZONES | | | NEED TO HAVE A FINISH FLOOR ELEVATION 2' ABOVE THE BASE | | | FLOOD ELEVATION. | | | CITY ORDINANCE 4729-17 SEC. 18-34. | | | | | | 5- BEDROOM EGRESS WINDOWS DON'T COMPLY WITH SEC. | | | R310.2.1 FBC-RESIDENTIAL. WINDOW #1 SHOWS A 4'-3" HIGH | | | SINGLE HUNG WINDOW. THIS WINDOW DOESN'T PROVIDE THE | | | MIN. CLEAR HEIGHT OPENING OF 24". REVISE AS REQUIRED. | | | | | | 6- IT LOOKS LIKE NEW ENTRY DOORS DON'T COMPLY WITH | | | EGRESS SEC. R11.2 FBC-RESIDENTIAL. NEED AT LAST ONE | | | DOOR THAT PROVIDES MIN. 32" CLEAR OPENING. REVISE SIZE | | | OF DOORS. | | | | | | 7- A) DESIGN PARAMETERS ON SHEET A1 SPECIFIED THAT | | | BUILDING IS LOCATED IN EXPOSURE "D". WINDOWS DESIGN | | | PRESSURES SHOWN ON THE EXTERIOR ELEVATIONS ON SHEET A2 | | | DON'T CORRESPOND TO EXPOSURE "D". REVISE AS REQUIRED. | | | SEC. R301.2.1 FBC-RESIDENTIAL. | | | | | | B) PROVIDE THE DESIGN PRESSURES FOR EXTERIOR DOORS. | | | SEC. R301.2.1 FBC-RESIDENTIAL. ONLY THE DESIGN | | | PRESSURES FOR WINDOWS WERE GIVEN. | | | | | | 8- REVISE THE MINIMUM COMPRESSIVE STRENGTH OF CONCRETE | | | SLAB SPECIFIED ON THE SECTION A ON SHEET A1 AND | | | FOUNDATION PLAN ON SHEET A3. 2,000PSI IS TOO LOW. SEE | | | SEC. R402.2 FBC-RESIDENTIAL AND REVISE AS REQUIRED. | | | | | | 9- SPECIFY ROOF CROSS VENTILATION AS REQUIRED BY SEC. | | | R806 FBC-RESIDENTIAL. SPECIFY SIZE AND LOCATION OF | | | VENTS. SECTION A ON SHEET A1 DOESN'T PROVIDE THIS | | | INFORMATION. | | | | | | 10- ROOF PITCH OF 2:12 TO LESS THAN 4:12 REQUIRES TWO | | | LAYERS OF UNDERLAYMENT AS REQUIRED BY SEC. R905.1.1 | | | FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS ON PLANS. | | | | | | 11- SPECIFY ATTIC ACCESS SIZE AND LOCATION FOR THE | | | PROPOSED ADDITION. SEC. R307.1 FBC-RESIDENTIAL. | | | | | | 12-SHOW ON PLANS CARBON MONOXIDE ALARMS BY ALL THE | | | BEDROOMS AS REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL. | | | | | | 13- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL) | | | | | | A) INSWING ENTRY DOORS WITH TRANSOM ABOVE AS SHOWN ON | | | PLANS. | | | | | | B)SINGLE HUNG WINDOWS. | | | | | | C) WINDOW MULLIONS AS SHOWN ON PLANS. REQUIRED: CLEARLY | | | SPECIFY MULLION SIZE TO BE USED TO VERIFY COMPLIANCE | | | WITH THE CALCULATED DESIGN PRESSURES. | | | | | | D) ROOF FINISH MATERIAL. | | | | | | E) PRECAST LINTELS AS SHOWN ON PLANS. | | | | | | 14- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN | | | WRITING (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 15- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. VALUATION WAS UPDATED TO $126,363. THE | | | PERMIT FEE BALANCE IS $2828.90 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-27 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-08-05 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-08-05 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-01 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-01 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2019-03-01 10:42:31 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN SHOWS EXISTING RENOVATION AND NEW ADDITION | | | AREAS. PLEASE CLARIFY. IS THIS AN EXISTING RENOVATION | | | THAT IS BEING REVISED, OR IS THIS A NEW PERMIT FOR AN | | | ADDITION? THE PLAN REVIEWER DOES NOT SEE AN EXISTING | | | RENOVATION PERMIT IN OUR SYSTEM. WPB FBC 107.2.1 | | | 2. PROVIDE RISER DIAGRAM OF EXISTING AND PROPOSED | | | SERVICE, SHOWING ALL DETAILS OF SERVICE EQUIPMENT, | | | UNDERGROUND OR OVERHEAD SERVICE, WIRE AND BREAKER SIZES | | | FOR SERVICE AND FEED TO ANY SUB-PANEL(S). SHOW GEC SIZE | | | AND SYSTEM, SHOW INTERSYSTEM BONDING TERMINATION POINT. | | | NEC 215.5, 230, 250.50, 250.94, 408.30; FBC RE E3706.1, | | | E3608.1, E3609.3; WPB FBC 107.2.1 | | | 3. SHOW LOCATION OF ELECTRICAL SERVICE AND PANEL ON | | | PLAN. WPB FBC 107.2.1 | | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 5. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | | 801.2, OR 901.2 AS APPLICABLE. | | | 6. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 | | | 7. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | 8. NOTE 2 STATES THE 2011 NEC AS BASIS FOR DESIGN, | | | WHICH IS NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC | | | PREFACE | | | 9. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 10. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC RE R315.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-27 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-08-20 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-08-12 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-07-17 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-11 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-08 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2019-03-11 08:08:29 | 3/11 TO CT DESK / S.HILL | | | | | 2019-02-11 11:21:24 | R13 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-09-10 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-08-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2019-09-10 11:49:28 | RECEIPT MU-2019-0911-106 - $427.67 - PAID | | 2019-08-27 16:35:50 | 8/27/19 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-08 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-08 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2019-03-08 12:22:33 | IMPACT FEES - PAPER SUBMITTALS | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-27 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-09 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2019-08-09 10:18:01 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE ENERGY SUBMITTAL FOR ADDITION. | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | | | | 2. DESIGNER OF RECORD TO SIGN PLAN. | | | FBC 107.1 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT, | | | INTERIOR DESIGNER, LANDSCAPE ARCHITECT, OR ENGINEER | | | LEGALLY REGISTERED UNDER THE LAWS OF THIS STATE | | | REGULATING THE PRACTICE OF ARCHITECTURE OR INTERIOR | | | DESIGN AS PROVIDED FOR IN CHAPTER 481, FLORIDA | | | STATUTES, PART I, OR LANDSCAPE ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, PART II, OR | | | ENGINEERING AS PROVIDED FOR IN CHAPTER 471, FLORIDA | | | STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE. | | | | | | DIGITAL REVIEW | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-11 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-11 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2019-03-11 12:19:49 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. CANNOT DETERMINE IF ADDITION ENCROACHES INTO THE | | | SPECIAL FLOOD HAZARD AREA TRANSECTING THE PROPERTY. | | | 2. PROVIDE SURVEY AND SITE PLAN. | | | 3. IF ADDITION QUALIFIES STRUCTURE AS A SUBSTANTIAL | | | IMPROVEMENT, ALL MECHANICAL EQUIPTMENT AND UTILITIES | | | SHALL BE ELEVATED AT OR ABOVE THE DESIGN FLOOD | | | ELEVATION. | | | | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | | | ADVISORY: RETURN AIR GRILLS SHOULD BE LOCATED ON | | | OPPOSITE SIDE OF ROOM THAT SUPPLY AIR IS LOCATED. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-27 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2019-08-27 12:17:29 | A VIDEO OF THE UNDERSLAB PIPING SHALL BE MADE AND | | | PRESENTED TO THE PLUMBING INSPECTOR FOR REVIEW. CT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-06 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-06 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2019-08-06 15:00:17 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 96= STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2NDT REVIEW | | | PLUMBING COMMEMTS: DENIED | | | 1. UPON REVIEW OF THE PLANS UNDER PERMIT #97011131 AND | | | 19030705, THE FOLLOWING SHALL APPLY: | | | | | | A. PER WPB FBC 107.2.1, PROVIDE ADDITIONAL | | | CLARIFICATION ON PLAN SHEET A1; CLOUD EACH | | | NON-PERMITTED RECONFIGURATION AND ADDITION. CLARIFY | | | BATH AS BUILT AS ADDED BATH. PROVIDE PLAN SHOWING THE | | | EXISTING KITCHEN, LAUNDRY AND BATH CONFIGURATION AND | | | LOCATIONS AT THE TIME OF THE ISSUANCE OF PERMIT | | | #97011131. SEE PERMIT #97011131 PLAN SHEETS 2 AND 3. | | | B. PER WPB FBC 107.2.1, THE GAS TANKLESS WATER HEATER | | | SHALL BE SHOWN AND IDENTIFIED ON PLAN SHEET A1. | | | C. SEE PLUMBING NOTES ON PLAN SHEET A2; PER WPB FBC | | | 107.2.1, THE PLUMBING SHALL COMPLY WITH FLORIDA | | | RESIDENTIAL BUILDING CODE 2017. | | | D. SEE PLUMBING PIPING ON PLAN SHEET A2; PER FBC RES | | | P3104.3 AND P3104.4, DRY VENT SHALL CONNECT ABOVE THE | | | CENTERLINE OF THE HORIZONTAL DRAIN PIPE AND RISE | | | VERTICALLY TO NOT LESS THAN 6? ABOVE THE FLOOD LEVEL | | | RIM OF THE HIGHEST FIXTURE BEING VENTED. | | | E. IS THE NEW ADDITION TO BE BUILT OVER THE EXISTING | | | SANITARY SEWER/BUILDING DRAIN? SHOW LOCATION OF | | | EXISTING SANITARY SEWER/BUILDING DRAIN AND WHERE ADDED | | | BATH WILL CONNECT INTO THE SAME. | | | | | | 2. AS A PROVISO TO AN APPROVED PERMIT, A VIDEO OF THE | | | UNDERSLAB PIPING SHALL BE MADE AND PRESENTED TO THE | | | PLUMBING INSPECTOR AT THE FIRST PLUMBING INSPECTION, | | | WHICH SHALL BE REVIEWED BY THE CHIEF PLUMBING INSPECTOR | | | FOR CODE COMPLIANCE. | | | 3. SUBMITTAL OF ADDITIONAL AND/OR REVISED MATERIALS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19020363 936 UPLAND RD | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-03-07 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-03-07 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2019-03-07 11:08:09 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: DENIED | | | PLUMBING COMMENTS: | | | 1. PER WPB FBC 107.2.1, PROVIDE A PLAN SHOWING THE | | | EXISTING KITCHEN CONFIGURATION AND THE PROPOSED KITCHEN | | | CONFIGURATION OR STATE ON PLAN SHEET A1 "SCOPE OF WORK" | | | NOTE 5 THAT THERE IS NO RECONFIGURATION OF SINK AND | | | APPLIANCE RELOCATION AND THAT ALL FIXTURES AND | | | APPLIANCES REQUIRING WATER AND WASTE CONNECTIONS SHALL | | | CONNECT TO EXISTING SUPPLY LINES AND OUTLETS AS DEFINED | | | BY WPB FBC 105.2 WORK EXEMPT FROM PERMIT. | | | 2. WHAT DOES THE TERM EXISTING RENOVATION APPLY TO? | | | THERE DOES NOT APPEAR TO HAVE BEEN A PREVIOUS PERMITTED | | | RENOVATION ON THIS PROPERTY. PLEASE CLARIFY PER WPB FBC | | | 107.2.1 | | | 3. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST PLUMBING. WPB FBC 109.3 | | | | | | | | | END OF PLUMBING COMMENTS | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-27 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2019-08-27 12:15:50 | PROVISO - ROOFING PRODUCT APPROVALS SHALL BE SUBMITTED | | | FOR REVIEW PRIOR TO INSTALLATION. CT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-09 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2019-08-09 10:20:15 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | | SYSTEM COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-08 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-08 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2019-03-08 12:23:45 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL) | | | | | | A) ROOF FINISH MATERIAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-27 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2019-08-26 13:54:29 | 8/26/19 DIGITALLY SIGNED COVER SHEET IN "SIGNATURES" | | | FOLDER. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-09 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2019-08-09 10:27:28 | BUILDING PLAN REVIEW - DIGITAL SIGNATURES AND SEALS | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTE: ORIGINAL PAPER SUBMITTAL HAS BEEN CHANGED TO | | | ELETRONIC SUBMITTAL. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | | | | | | 2019-08-02 15:28:02 | 8/2/19 HARD COPIES OF PLANS LOCATED IN LIBRARY. LEM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-08-28 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-08-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-08-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-28 14:11:26 | *********************************************ZONING | | | PROVISO********************************* | | | | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | | THE FOLLOWING | | | CONDITIONS SHALL BE ADDRESSED: | | | | | | 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN, | | | SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW. | | | | | | 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED | | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | | LANDSCAPE INSPECTION. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-08-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-08-27 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-27 13:17:40 | ***********************ZONING REVIEW | | | FAILED********************** | | | | | | THE AMENDED PROJECT VALUE TRIGGERS THE LANDSCAPE CODE. | | | PLEASE PROVIDE THE FOLLOWING LANDSCAPE REQUIREMENTS. | | | | | | PROVIDE LANDSCAPING. | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-12 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-08-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-08-12 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-12 10:09:48 | ***********************ZONING REVIEW | | | FAILED********************** | | | | | | THE AMENDED PROJECT VALUE TRIGGERS THE LANDSCAPE CODE. | | | PLEASE PROVIDE THE FOLLOWING LANDSCAPE REQUIREMENTS. | | | | | | PROVIDE LANDSCAPING. | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-02-15 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2019-02-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-02-15 16:33:47 | *************************************ZONING REVIEW | | | FAILED****************************** | | | | | | IS THE FOOTPRINT OF THE EXISTING HOME EXPANDING? | | | | | | PROVIDE A SURVEY AND SITE PLAN OF PROPERTY SHOWING ALL | | | (EXISTING AND NEW) SETBACKS. | | | | | | ADDITIONAL COMMENTS MAY FOLLOW FURTHER REVIEW. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|