Plan Review Details - Permit 19020342
Plan Review Stops For Permit 19020342
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-07-17 Cont ID  
Sent By pvalenti Date 2019-07-17 Time 17:24 Rev Time 0.00
Received By pvalenti Date 2019-07-17 Time 17:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-06-05 Cont ID  
Sent By shill Date 2019-06-05 Time 07:57 Rev Time 0.00
Received By shill Date 2019-06-05 Time 07:57 Sent To  
Notes
2019-06-05 08:09:462017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19020342
 ADD: 1638 EMBASSY DR. SUITE: 301
 CONT: MJR CUSTOM HOMES
 TEL: 561-906-7574
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: 6/5/2019
 ACTION: DENIED
  
 1) OK
  
 2) OK
  
 3) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
  
 3A) UNDER WHAT EDITION OF THE FLORIDA BUILDING CODE WAS
 THE PLANS DESIGNED?
  
 3B) UNDER THE EXISTING BUILDING CODE UNDER WHICH METHOD
 WERE THE PLANS DEVELOPED?
  
 3C) 301.1 THE ALTERATION OF ALL EXISTING BUILDINGS
 SHALL COMPLY WITH ONE OF THE METHODS LISTED IN SECTIONS
 301.1.1 THROUGH 301.1.3 AS SELECTED BY THE APPLICANT.
  
 3C)(1) 301.1.1 PRESCRIPTIVE COMPLIANCE METHOD.
  
 3C)(2) 301.1.2 WORK AREA COMPLIANCE METHOD.
  
 3C)(3) 01.1.3 PERFORMANCE COMPLIANCE METHOD.
  
 4) 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY
 REQUIREMENTS SHALL BE DETERMINED.
  
 5) 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED
 (SEE SECTION 503).
  
 5) 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL
 INCLUDE THE FOLLOWING COMPONENTS:
 FIRE-RESISTANT SEPARATIONS, THE WALL SEPARATING THE 2
 UNITS WHERE THE WORK IS COMMENCING ON THE
 SHOWER, THE PLANS ARE NOT CLEAR IF THE FIRE RATED
 DRYWALL IS BEING REMOVED?
  
 6) 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE:
 PRE-ENGINEERED SYSTEMS. IS THE UNIT FIRE SPRINKLERED OR
 NOT?
  
 7) SINCE THE DEMO NOTE (1) INDICATES THE REMOVAL OF
 FLOOR TILE, THERE IS NO INFORMATION AS TO THE NEW FLOOR
 FINISH OR COMPLIANCE WITH:
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2017)
 FOR TILE, STONE, MARBLE, VINYL (LVT) OR (LVP) AND WOOD
 FLOORING ALL NEED TO HAVE HAD THE SOUND UNDERLAYMENT
 TESTED FLOOR ASSEMBLIES TO THE FOLLOWING STANDARDS AND
 MEET THE QUALIFICATIONS LISTED UNDER EACH OF THE
 STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ NO
 DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
  
 7A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 7B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 7C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 PLAN SPECIFIES "PROFLEX 90 OR EQUIVALENT". SPECIFY SLAB
 THICKNESS AND PROVIDE TEST REPORTS FOR THE PRODUCT
 PROPOSED.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-02-25 Cont ID  
Sent By jwitmer Date 2019-02-25 Time 08:03 Rev Time 0.00
Received By jwitmer Date 2019-02-25 Time 07:26 Sent To  
Notes
2019-02-25 08:03:282017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19020342
 ADD: 1638 EMBASSY DR. SUITE: 301
 CONT: MJR CUSTOM HOMES
 TEL: 561-906-7574
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. FEB. 25/ 2019
 ACTION: DENIED
  
 1A) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.3.4.3 CERTIFICATION BY CONTRACTOR.
 PLEASE NOTE THE EXCEPTION TO ENGINEERED PLANS UNDER
 471.003(H) ELECTRICAL/ PLUMBING/ MECHANICAL,
 481.229(1)(C) (BUILDING) REQUIRES THE CONTRACTOR FOR
 THAT TRADE THAT WILL BE LICENSED IN THAT TRADE, WILL
 ALSO BE THE CONTRACTOR THAT DESIGNS THE SYSTEM UNDER
 THAT TRADE. FOR EACH TRADE THE CONTRACTOR RESPONSIBLE
 FOR THE DESIGN UNDER THE TRADE LICENSED IN MUST PRINT
 THEIR NAME, SIGN THEIR NAME AND LICENSE NUMBER, NOTE
 THESE PLANS APPEAR TO BE DRAWN BY ONE INDUVIAL, THEY
 WOULD HAVE TO BE LICENSED AS A BUILDING, ELECTRICAL AND
 PLUMBING CONTRACTOR TO SUBMIT ALL THESE TRADES UNDER
 ONE SHEET.
  
 1B) PLEASE NOTE THERE ARE NOTES ON THE DEMO PLAN NOTED
 # 1 TO REMOVE ALL TILE THROUGHOUT THE HOUSE, PLEASE
 UPDATE THE PLANS THIS IS NOT A SINGLE FAMILY HOUSE.
 ALSO UNDER THE GENERAL NOTES THERE ARE REFERENCES TO
 SHUTTING OFF THE MAIN WATER VALVE TO THE HOUSE, AND
 DRIVEWAYS AND OTHER AREAS ARE TO BE PROTECTED. IT WOULD
 APPEAR WHOMEVER DESIGNED THIS PLAN IS A RESIDENTIAL
 DRAFTSMAN.
  
 2) PLEASE NOTE WITHIN THE ONE SHEET SUBMITTED THERE IS
 A INTERIOR DEMO FLOOR PLAN, NEW FLOOR PLAN FOR PLUMBING
 AND A ELECTRICAL FLOOR PLAN, THERE IS NO FLOOR PLAN FOR
 THE PROPOSED BUILDING PORTION OF THE PROJECT.
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 3) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
  
 3A) UNDER WHAT EDITION OF THE FLORIDA BUILDING CODE WAS
 THE PLANS DESIGNED?
  
 3B) UNDER THE EXISTING BUILDING CODE UNDER WHICH METHOD
 WERE THE PLANS DEVELOPED?
  
 3C) 301.1 THE ALTERATION OF ALL EXISTING BUILDINGS
 SHALL COMPLY WITH ONE OF THE METHODS LISTED IN SECTIONS
 301.1.1 THROUGH 301.1.3 AS SELECTED BY THE APPLICANT.
  
 3C)(1) 301.1.1 PRESCRIPTIVE COMPLIANCE METHOD.
  
 3C)(2) 301.1.2 WORK AREA COMPLIANCE METHOD.
  
 3C)(3) 01.1.3 PERFORMANCE COMPLIANCE METHOD.
  
 4) 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY
 REQUIREMENTS SHALL BE DETERMINED.
  
 5) 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED
 (SEE SECTION 503).
  
 5) 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL
 INCLUDE THE FOLLOWING COMPONENTS:
 FIRE-RESISTANT SEPARATIONS, THE WALL SEPARATING THE 2
 UNITS WHERE THE WORK IS COMMENCING ON THE
 SHOWER, THE PLANS ARE NOT CLEAR IF THE FIRE RATED
 DRYWALL IS BEING REMOVED?
  
 6) 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE:
 PRE-ENGINEERED SYSTEMS. IS THE UNIT FIRE SPRINKLERED OR
 NOT?
  
 7) SINCE THE DEMO NOTE (1) INDICATES THE REMOVAL OF
 FLOOR TILE, THERE IS NO INFORMATION AS TO THE NEW FLOOR
 FINISH OR COMPLIANCE WITH:
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2017)
 FOR TILE, STONE, MARBLE, VINYL (LVT) OR (LVP) AND WOOD
 FLOORING ALL NEED TO HAVE HAD THE SOUND UNDERLAYMENT
 TESTED FLOOR ASSEMBLIES TO THE FOLLOWING STANDARDS AND
 MEET THE QUALIFICATIONS LISTED UNDER EACH OF THE
 STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ NO
 DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
  
 7A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 7B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 7C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-07-16 Cont ID  
Sent By jpearson Date 2019-07-16 Time 09:40 Rev Time 0.00
Received By jpearson Date 2019-07-16 Time 09:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-06-03 Cont ID  
Sent By ppetty Date 2019-06-03 Time 11:45 Rev Time 0.00
Received By ppetty Date 2019-06-03 Time 11:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-03-01 Cont ID  
Sent By jpearson Date 2019-03-01 Time 08:58 Rev Time 0.00
Received By jpearson Date 2019-03-01 Time 08:30 Sent To I
Notes
2019-03-01 08:58:48CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY
 THE ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H);
 471.025; WPB FBC 107.2.1, 107.3.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-06-24 Cont ID  
Sent By pleduc Date 2019-06-24 Time   Rev Time 0.00
Received By pleduc Date 2019-06-24 Time 10:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-05-23 Cont ID  
Sent By pleduc Date 2019-05-23 Time   Rev Time 0.00
Received By pleduc Date 2019-05-23 Time 15:34 Sent To  
Notes
2019-05-23 15:37:025/23/19
  
  
 THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) PLEASE ENSURE THAT ANY FIRE ALARM DEVICES , AS WELL
 AS, THE FIRE ALARM SYSTEM REMOANS ACTIVE THROUGHOUT
 CONSTRUCTION.
  
 2) IF ANY WORK INVOLVES THE REMOVAL AND/OR RELOCATION
 OF ANY FA DEVICE THE WORK SHALL BE DONE UNDER SEPARATE
 SHOP DRAWINGS AND BY A CERTIFIED FIRE ALARM CONTRACTOR.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-02-13 Cont ID  
Sent By pleduc Date 2019-02-13 Time   Rev Time 0.00
Received By pleduc Date 2019-02-13 Time 13:55 Sent To  
Notes
2019-02-13 13:58:59THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) PLEASE ENSURE THAT ANY FIRE ALARM DEVICES , AS WELL
 AS, THE FIRE ALARM SYSTEM REMOANS ACTIVE THROUGHOUT
 CONSTRUCTION.
  
 2) IF ANY WORK INVOLVES THE REMOVAL AND/OR RELOCATION
 OF ANY FA DEVICE THE WORK SHALL BE DONE UNDER SEPARATE
 SHOP DRAWINGS AND BY A CERTIFIED FIRE ALARM CONTRACTOR.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-07-17 Cont ID  
Sent By pvalenti Date 2019-07-17 Time 17:24 Rev Time 0.00
Received By pvalenti Date 2019-06-20 Time 14:52 Sent To  
Notes
2019-06-20 14:52:48B28

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-05 Cont ID  
Sent By shill Date 2019-06-05 Time 08:09 Rev Time 0.00
Received By shill Date 2019-05-21 Time 14:03 Sent To  
Notes
2019-05-22 14:03:29B08

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-03-01 Time   Rev Time 0.00
Received By lmarchan Date 2019-02-08 Time 11:23 Sent To  
Notes
2019-02-11 11:23:21B22

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-07-01 Cont ID  
Sent By gjohnson Date 2019-07-01 Time 12:17 Rev Time 0.00
Received By gjohnson Date 2019-07-01 Time 11:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-06-04 Cont ID  
Sent By jesmith Date 2019-06-04 Time 12:15 Rev Time 0.00
Received By jesmith Date 2019-06-04 Time 11:56 Sent To  
Notes
2019-06-04 12:15:13APPROVED
 ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-02-28 Cont ID  
Sent By jesmith Date 2019-02-28 Time 15:15 Rev Time 0.00
Received By jesmith Date 2019-02-28 Time 15:15 Sent To  
Notes
2019-02-28 15:15:46APPROVED
 ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL
 SCOPE IS LIMITED TO EXACT REPLACEMENT OF KITCHEN AND
 BATH FIXTURES.