Plan Review Details - Permit 19020003
Plan Review Stops For Permit 19020003
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-23 Cont ID  
Sent By cthroop Date 2019-09-23 Time 08:47 Rev Time 0.00
Received By cthroop Date 2019-09-20 Time 13:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-24 Cont ID  
Sent By cthroop Date 2019-07-24 Time 15:49 Rev Time 0.00
Received By cthroop Date 2019-07-19 Time 07:00 Sent To  
Notes
2019-07-24 15:52:56BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SITE PLAN.
 2. PROVIDE DRAINAGE PLAN.
 NOTE: DRAINAGE PLAN MAY BE OVERLAYED ONTO SITE PLAN.
  
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY.
  
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10
 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE
 DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING
 FOUNDATION SHALL BE SLOPED A MINIMUM OF
 2 PERCENT AWAY FROM THE BUILDING.
  
 FBC R 401.3 (DRAINAGE)
 FBC 107.2.5 (SITE PLAN)
 FBC 110.9 (IMPACT OF CONSTRUCTION)
  
 3. IDENTIFY EGRESS WINDOW AT NEW BEDROOM.
 107.2.3 MEANS OF EGRESS. THE CONSTRUCTION DOCUMENTS
 SHALL SHOW IN SUFFICIENT DETAIL THE LOCATION,
 CONSTRUCTION, SIZE AND CHARACTER OF ALL PORTIONS OF THE
 MEANS OF EGRESS IN COMPLIANCE WITH THE PROVISIONS OF
 THIS CODE. IN OTHER THAN OCCUPANCIES IN GROUPS R-2,
 R-3, AND I-1, THE CONSTRUCTION DOCUMENTS SHALL
 DESIGNATE THE NUMBER OF OCCUPANTS TO BE ACCOMMODATED ON
 EVERY FLOOR, AND IN ALL ROOMS AND SPACES.
  
 4. PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED BY
 DESIGNER.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-09-11 Cont ID  
Sent By jleahy Date 2019-09-11 Time 10:26 Rev Time 0.00
Received By jleahy Date 2019-09-11 Time 10:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-07-23 Cont ID  
Sent By jleahy Date 2019-07-23 Time 07:11 Rev Time 0.00
Received By jleahy Date 2019-07-19 Time 07:00 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-09-25 Cont ID  
Sent By fmittner Date 2019-09-25 Time 12:55 Rev Time 0.00
Received By fmittner Date 2019-09-25 Time 12:55 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-07-18 Cont ID  
Sent By fmittner Date 2019-07-18 Time 16:39 Rev Time 0.00
Received By fmittner Date 2019-07-18 Time 16:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-25 Cont ID  
Sent By shill Date 2019-09-25 Time 15:25 Rev Time 0.00
Received By shill Date 2019-08-28 Time 08:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-24 Cont ID  
Sent By lmarchan Date 2019-07-24 Time 15:55 Rev Time 0.00
Received By cthroop Date 2019-06-24 Time 15:52 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-10-01 Cont ID  
Sent By lmarchan Date 2019-10-01 Time 10:44 Rev Time 0.00
Received By lmarchan Date 2019-09-23 Time 15:55 Sent To  
Notes
2019-10-01 10:44:31RECEIPT - 2019-1002-45 - $242.50 - PAID
2019-09-23 15:55:129/23/19 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-07-24 Cont ID  
Sent By cthroop Date 2019-07-24 Time 15:45 Rev Time 0.00
Received By cthroop Date 2019-07-19 Time 07:00 Sent To  
Notes
2019-07-24 15:46:02PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-09-11 Cont ID  
Sent By cmontell Date 2019-09-11 Time 15:00 Rev Time 0.00
Received By cmontell Date 2019-09-11 Time 15:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-07-18 Cont ID  
Sent By cmontell Date 2019-07-18 Time 10:55 Rev Time 0.00
Received By cmontell Date 2019-07-18 Time 10:24 Sent To  
Notes
2019-07-18 10:54:58MECHANICAL PLAN REVIEW FAIL
  
 1 - NEED RETURN AIR IN SITTING ROOM PER 2017 FLORIDA
 BUILDING CODE - RESIDENTIAL, SIXTH EDITION SEC M1602.3
 BALANCED RETURN AIR.
  
 CHRIS MONTELLO
 561-805-6733
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-09-10 Cont ID  
Sent By jesmith Date 2019-09-10 Time 14:24 Rev Time 0.00
Received By jesmith Date 2019-09-10 Time 14:23 Sent To  
Notes
2019-09-10 14:24:11PLUMBING COMMEMTS: APPROVED
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-07-11 Cont ID  
Sent By jesmith Date 2019-07-11 Time 14:42 Rev Time 0.00
Received By jesmith Date 2019-07-11 Time 14:42 Sent To  
Notes
2019-07-11 14:42:34CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 30A
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMEMTS: DENIED
 1. PER WPB FBC 107.2.1, ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN.PROVIDE ON PLAN SHEET P.1.
 2. THERE IS NO DIGITAL SIGNATURE ON PLAN SHEET P.1.
 3. SANITARY RISER DIAGRAM IS NOT CODE COMPLIANT. REFER
 TO REDLINED SKETCHING ON PLAN SHEET P.1 TO PRODUCE
 COMPLIANT DRAWING IN ACCORDANCE WITH FBC RES SECTION
 P3108.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19020003 224 ALMERIA RD
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-09-23 Cont ID  
Sent By cthroop Date 2019-09-23 Time 08:46 Rev Time 0.00
Received By cthroop Date 2019-09-20 Time 13:57 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-07-24 Cont ID  
Sent By cthroop Date 2019-07-24 Time 15:46 Rev Time 0.00
Received By cthroop Date 2019-07-19 Time 07:00 Sent To  
Notes
2019-07-24 15:49:27BUILDING PLAN REVIEW - ROOFING
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. CONTRACTOR TO SELECT ROOFING SYSTEM COMPONENTS FROM
 NOA.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. NOA/PRODUCT APPROVAL SHALL BE REVIEWED AND APPROVED
 BY DESIGNER.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5) AND F.S. 481.229.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-09-23 Cont ID  
Sent By cthroop Date 2019-09-23 Time 08:46 Rev Time 0.00
Received By cthroop Date 2019-09-20 Time 13:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-07-24 Cont ID  
Sent By cthroop Date 2019-07-24 Time 15:40 Rev Time 0.00
Received By cthroop Date 2019-07-24 Time 11:29 Sent To  
Notes
2019-07-24 15:45:11BUILDING PLAN REVIEW - SIGNATURE REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. HVAC LOAD CALC'S, AND ELECTRICAL PLAN REQUIRE NAME
 AND SIGNATURE OF DESIGNER.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5) AND F.S. 481.229.
  
 2. PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED BY
 DESIGNER.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-09-25 Cont ID  
Sent By fmittner Date 2019-09-25 Time 12:54 Rev Time 0.00
Received By fmittner Date 2019-09-25 Time 12:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-07-18 Cont ID  
Sent By fmittner Date 2019-07-18 Time 16:38 Rev Time 0.00
Received By fmittner Date 2019-07-18 Time 16:38 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy