Plan Review Details - Permit 19011177
| Plan Review Stops For Permit 19011177 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-02-05 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-02-05 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-02-04 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-02-04 |
Time |
17:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-03-05 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-03-05 |
Time |
07:03 |
Sent To |
I |
|
| Notes |
| 2019-03-05 07:19:11 | THERE IS NO HEATER SHOWN ON THIS POOL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-03-22 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-03-14 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2019-03-15 15:42:44 | 3/15 TO T.HUNT DESK | | | | | | | | 2019-03-15 11:10:45 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-03-05 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-01-28 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2019-01-29 14:29:51 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-03-20 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-03-19 |
Time |
12:34 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-03-04 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-02-26 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2019-03-04 13:21:05 | 1) ALL HOSE BIBBS SHALL BE SEPARATELY VALVED PER 2017 | | | FBC-PLUMBING SEC.606.2 (2). | | | 2) SHT. SP-1 SHOWS THE VAK-PAK WASTE TO THE STORM | | | DRAINAGE SYSTEM. ONLY STORMWATER MAY DISCHARGE INTO THE | | | CITY'S STORM DRAINAGE SYSTEM PER CITY OF WPB CODE OF | | | ORDINANCES CHAPTER 90, ARTICLE V, SEC. 90-203. CONTACT | | | MANNY GONZALEZ IN THE ENGINEERING DEPT. AT | | | 561-494-1040. | | | 3) SHT. 5 OF 7 - NOTES REFER TO THE FIFTH EDITION OF | | | THE FLORIDA BUILDING CODE. THE CODE IN EFFECT IS THE | | | 6TH EDITION. REVIS EHTE NOTE. | | | 4) SHT. PPD-1 - PLUMBING NOTES #1 REFERS TO THE 2014 | | | FBC. THE CODE IN EFFECT IS THE 2017 FBC. PLEAS REVISE | | | THE NOTE. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
AH |
Date |
2019-03-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
ahansen |
Date |
2019-03-22 |
Time |
11:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
ahansen |
Date |
2019-01-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
ahansen |
Date |
2019-01-29 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2019-01-29 15:57:12 | SENT TO ALEX |
|
|
|