|
 |
 |
 |
 |
 |
Plan Review Details - Permit 19011023
| Plan Review Stops For Permit 19011023 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-13 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-13 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-13 |
Time |
08:35 |
Sent To |
G |
|
| Notes |
| 2019-02-13 08:46:46 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THIS PROPERTY IS IN THE FLOOD ZONE. PLEASE PROVIDE | | | THE PROPOSED ELEVATION WHERE THE GENERATOR IS GOING TO | | | BE INSTALLED. ALL GENERATORS, ELECTRICAL EQUIPMENT AND | | | FUEL TANKS SHALL BE INSTALLED 6 INCHES ABOVE THE BASE | | | FLOOD ELEVATION. FBC 107 | | | | | | 2. ON JULY 2018 A RESIDENTIAL GENERATOR PERMIT WAS | | | PROVIDED FOR A 22K GENERATOR, PERMIT #18070788. WHAT | | | HAPPEND WITH THIS GENERATOR? IS THE PROPERTY GOING TO | | | HAVE TWO GENERATORS? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-02-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-25 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-25 |
Time |
09:07 |
Sent To |
I |
|
| Notes |
| 2019-02-25 09:07:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NO ELECTRICAL ISSUES BUILDING COMMENTS NEED TO BE | | | ADDRESSED IN REFERENCE TO PREVIOUS PERMIT. WPB FBC | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-02-23 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-02-23 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-02-23 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-02-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-24 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2019-01-25 13:40:11 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-02-04 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-02-04 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |