Plan Review Details - Permit 19010816
| Plan Review Stops For Permit 19010816 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-08 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-08 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-23 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-23 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-23 |
Time |
15:33 |
Sent To |
E |
|
| Notes |
| 2019-01-23 15:44:27 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLEASE INDICATE WICH UNIT WERE USED FOR INTERIOR | | | SPACE DIMENSION (E.I FEET; INCH). FBC 107 | | | | | | 2. PLEASE INDICATE EXISTING AND PROPOSED LOCATION OF | | | THE PLUMBING FIXTURES. FBC 107 | | | | | | 3. PROVIDE WALL CONSTRUCTION DETAILS. NEW WALL | | | CONSTRUCTION MUST MEET THE REQUIREMENTS OF FBC | | | RESIDENTIAL CHAPTER 6. | | | | | | 4. ONE COPY OF EXISTING FLOOR PLAN AND ONE COPY OF | | | PROPOSED FLOOR PLAN WERE SUBMITTED. PLEASE PROVIDE A | | | MINIMUM OF TWO COPIES FOR ANY CONSTRUCTION DOCUMENT | | | SUBMITTED. | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-07 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-03-07 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-03-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-05 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-03-05 |
Time |
16:02 |
Sent To |
P |
|
| Notes |
| 2019-03-05 16:03:08 | NOT REAL CLEAR ON SCOPE OF WORK JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-01-30 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-01-30 |
Time |
07:47 |
Sent To |
P |
|
| Notes |
| 2019-01-30 07:49:02 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED A LAYOUT FOR THE ELECTRIC TO BE DEMOED. | | | | | | NEED TO SUBMIT FOR AN ELECTRICAL PERMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-08 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-15 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2019-02-19 13:41:26 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-01-31 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-01-18 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2019-01-22 14:39:05 | BLDG <5K |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-08 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-03-08 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-01-31 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-01-31 |
Time |
06:28 |
Sent To |
I |
|
| Notes |
| 2019-01-31 06:34:39 | 1) SUBMIT TWO COPIES OF EACH FLOOR PLAN. WPB AMEND. TO | | | FBC SEC. 107.1. | | | 2) SHOW THE SCOPE OF ANY PLUMBING WORK TO BE DONE ON | | | THE PLANS. IF NO PLUMBING WORK IS TO BE DONE, NOTE SUCH | | | ON THE PLANS. WPB AMEND. TO FBC SEC. 107.2.1. | | | 3) SHOW THE LOCATION OF ALL PLUMBING FIXTURES ON THE | | | PLANS. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy