| Plan Review Stops For Permit 19010813 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-04-03 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-04-03 |
Time |
10:27 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-03-06 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-03-06 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2019-03-06 15:08:20 | BUILDING REVIEW IS APPROVED PENDING PROOF OF APPROVAL | | | FROM PALM BEACH COUNTY DEPARTMENT OF AIRPORTS (FAA) AND | | | CITY OF WEST PALM BEACH ZONING DEPARTMENT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-02-01 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-02-01 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2019-02-01 17:33:57 | REVISION - PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE INCREASE IN HEIGHT OF THE NETTING POLES FROM | | | 150' ABOVE GRADE TO 160' ABOVE GRADE IS REQUIRED TO BE | | | APPROVED BY THE PALM BEACH COUNTY AIRPORT AND THE | | | CITY'S ZONING DEPARTMENT. | | | | | | 2) THE WINDLOAD ANALYSIS THAT WAS SUBMITTED HAS THE | | | VULT WIND SPEED AS 150 MPH AND BUILDING RISK CATEGORY | | | II. THE NETTING POLES SHOULD BE CLASSIFIED AS RISK | | | CATEGORY I. THIS PROJECT IS LOCATED BETWEEN THE 160 MPH | | | AND THE 150 MPH CONTOUR LINES ON THE WIND SPEED MAP FOR | | | RISK CATEGORY I. THE WIND SPEED FOR THIS PROJECT | | | LOCATION SHOULD BE 155 MPH VULT. 2014 FBC SECTION | | | 1604.5 & 1609.1 AND ASCE 7 - 10 | | | | | | 3) SHEET S5.2 OF THE PLANS HAS THE CORRECT BUILDING | | | RISK CATEGORY, HOWEVER, THE VULT WIND SPEED IS | | | INCORRECTLY SPECIFIED AS 150 MPH. THE WIND SPEED FOR | | | THIS PROJECT LOCATION SHOULD BE 155 MPH VULT. 2014 FBC | | | SECTION 1604.5 & 1609.1 AND ASCE 7 - 10. | | | | | | 4) ON SHEET S5.2, THE REINFORCING STEEL AND CONCRETE | | | NOTES SPECIFY ACI 318-05. THIS PROJECT IS PERMITTED | | | UNDER THE 2014 FLORIDA BUILDING CODE WHICH REFERENCES | | | THE 2011 EDITION OF ACI 318 (ACI 318-11). FBC CHAPTER | | | 35 | | | | | | 5) ON SHEET S5.2, THE STRUCTURAL STEEL NOTES SPECIFY | | | AISC 360-05. THIS PROJECT IS PERMITTED UNDER THE 2014 | | | FLORIDA BUILDING CODE WHICH REFERENCES THE 2010 EDITION | | | OF AISC 360 (AISC 360-10). FBC CHAPTER 35 | | | | | | 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-05-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-05-29 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-28 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-04-03 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-03-14 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-11 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-13 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-02-04 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-02-04 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-04-03 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-04-03 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-03-06 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-03-06 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-02-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-02-01 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-02-01 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2019-02-01 17:35:22 | SIGNATURES WILL BE VALIDATED WHEN PLANS ARE APPROVED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-05-29 |
|
|
Cont ID |
|
| Sent By |
hmtribou |
Date |
2019-05-29 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
hmtribou |
Date |
2019-05-29 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2019-05-29 12:02:32 | DESIGNER CERTIFICATION OR OTHER ACCEPTABLE | | | DOCUMENTATION IS REQUIRED THAT STATES THAT HEIGHT AND | | | CONDITIONS OF FINAL DETERMINATION LETTER OF FEDERAL | | | AVIATION ADMINISTRATION ARE MET BEFORE CERTIFICATE OF | | | OCCUPANCY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
hmtribou |
Date |
2019-03-21 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
hmtribou |
Date |
2019-03-21 |
Time |
14:10 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
hmtribou |
Date |
2019-03-11 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
hmtribou |
Date |
2019-03-11 |
Time |
10:21 |
Sent To |
I |
|
| Notes |
| 2019-03-04 10:20:04 | CURRENT APPROVAL OF POLE IS AS MAXIMUM OF 150 FEET. | | | SUBMITTED APPLICATION FOR MAXIMUM 160 FEET POLE HEIGHT | | | WILL GO TO CITY COMMISSION ON MARCH 11, 2019. ZONING | | | WILL NOT APPROVE UNTIL CITY COMMISSION APPROVAL. MAX. | | | HEIGHT FOR APPROVAL WILL BE 160 FEET, NOTE CURRENT | | | PLANS INDICATE POLES HIGHER THEN 160 FEET. PLEASE | | | PROVIDE FAA APPROVAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
hmtribou |
Date |
2019-02-04 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
hmtribou |
Date |
2019-02-04 |
Time |
10:48 |
Sent To |
I |
|
| Notes |
| 2019-02-04 10:52:34 | CURRENT APPROVAL OF POLE IS AS MAXIMUM OF 150 FEET. | | | SUBMITTED APPLICATION FOR MAXIMUM 160 FEET POLE HEIGHT | | | WILL GO TO CITY COMMISSION ON MARCH 11, 2019. ZONING | | | WILL NOT APPROVE UNTIL CITY COMMISSION APPROVAL. MAX. | | | HEIGHT FOR APPROVAL WILL BE 160 FEET, CURRENT PLANS | | | INDICATE POLES HIGHER THEN 160 FEET. |
|
|