Plan Review Details - Permit 19010680
Plan Review Stops For Permit 19010680
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-02-02 Cont ID  
Sent By pvalenti Date 2019-02-02 Time 13:43 Rev Time 0.00
Received By pvalenti Date 2019-02-02 Time 13:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-03-11 Cont ID  
Sent By jpearson Date 2019-03-11 Time 08:21 Rev Time 0.00
Received By jpearson Date 2019-03-11 Time 08:21 Sent To P
Notes
2019-03-11 08:21:16TO TIM.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-01-31 Cont ID  
Sent By jpearson Date 2019-01-31 Time 15:53 Rev Time 0.00
Received By jpearson Date 2019-01-31 Time 15:53 Sent To  
Notes
2019-01-31 15:53:25CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. THE LOAD CALCULATION PROVIDED DOES
 NOT ACCOUNT FOR ALL LOADS SHOWN IN PANEL SCHEDULE. NO
 LOAD CALCULATION IS PROVIDED FOR PANEL B, BUT IT
 APPEARS THAT THIS PANEL WILL BE OVERLOADED. DEMAND
 FACTORS ARE NOT PERMITTED TO BE USED ON FEEDERS LESS
 THAN 100 AMPS. THE LOAD IN PANEL A SHOWN FOR PANEL B IS
 MUCH LOWER THAN WHAT IS INCLUDED IN PANEL B. NEC 215.2,
 220, 408.30; FBC RE E3602.2
 2. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS
 INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES.
 SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902;
 FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE.
 3. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 4. IF NEW ADDITIONS TO LOAD REQUIRE AN INCREASE IN THE
 SERVICE SIZE, PROVIDE AIC RATING OF SERVICE DISCONNECT
 AND ANY PANELS. NEC 110.3, 110.9; FBC RE E3606.3
 5. IF NEW ADDITIONS TO LOAD REQUIRE AN INCREASE IN THE
 SERVICE SIZE, PROVIDE AVAILABLE SHORT CIRCUIT
 CALCULATION FOR SERVICE INCLUDING INFORMATION FROM THE
 POWER COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT
 CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC
 RATING OF THE SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9,
 110.10; FBC RE E3606.3
 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-11 Cont ID  
Sent By thunt Date 2019-03-11 Time 09:06 Rev Time 0.00
Received By thunt Date 2019-03-07 Time 16:39 Sent To  
Notes
2019-03-07 16:54:45RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-15 Cont ID  
Sent By cmontell Date 2019-02-15 Time 14:12 Rev Time 0.00
Received By cmontell Date 2019-02-15 Time 14:12 Sent To  
Notes
2019-01-18 14:09:39R20

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-02-15 Cont ID  
Sent By cmontell Date 2019-02-15 Time 14:11 Rev Time 0.00
Received By cmontell Date 2019-02-15 Time 14:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-03-11 Cont ID  
Sent By thunt Date 2019-03-11 Time 09:06 Rev Time 0.00
Received By thunt Date 2019-03-11 Time 08:44 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-01-31 Cont ID  
Sent By gjohnson Date 2019-01-31 Time 07:05 Rev Time 0.00
Received By gjohnson Date 2019-01-29 Time 08:33 Sent To  
Notes
2019-01-29 12:59:46 
 1ST REVIEW: 19010680
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE KEY NOTES ON P-1 DO NOT MATCH THE NUMBER TAGS
 THAT ARE ON THE PLAN NOTE CLEARLY ON THE PLAN WHAT
 FIXTURES ARE BEING CHANGE AND WHICH ONES ARE CHANGING
 LOCATIONS AND WHICH ONE ARE TO REMAIN IN SAME LOCATION.
 PER WPB AMEND TO FBC 107.2.1
  
 2. THE VALUATION OF THE JOB SEEMS TO BE LOW PLEASE SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. PER WPB AMEND TO FBC
 109.3
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved