Plan Review Details - Permit 19010660
Plan Review Stops For Permit 19010660
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-05-14 Cont ID  
Sent By dbattles Date 2019-05-14 Time 08:35 Rev Time 0.00
Received By dbattles Date 2019-05-14 Time 08:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-04-10 Cont ID  
Sent By dbattles Date 2019-04-10 Time 08:44 Rev Time 0.00
Received By dbattles Date 2019-04-10 Time 07:40 Sent To  
Notes
2019-04-10 08:53:05****CORRECTIONS****
 W.P.B. PERMIT: 1901
 REVIEWED: APRIL 10, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
  
 606.2 FBC[A] CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305,
 BATHROOMS HAVE BEEN RECONFIGURED AND THE LAVATORIES
 HAVE DISAPPEARED.
 PLEASE SHOW LAVATORIES AND SHOW CLEAR SPACE IN
 RESTROOMS TO SHOW NEW CONFIGURATION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-25 Cont ID  
Sent By dbattles Date 2019-01-25 Time 10:00 Rev Time 0.00
Received By dbattles Date 2019-01-24 Time 15:02 Sent To  
Notes
2019-01-25 10:00:25****CORRECTIONS****
 W.P.B. PERMIT: 19010660
 REVIEWED: JANUARY 25, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
  
 1. 107.2.1 FBC[B] INFORMATION ON CONSTRUCTION
 DOCUMENTS. THE SHEETS WERE UPLOADED AT 11X17 WITH A 1/4
 INCH SCALE INDICATED. TYPICALLY THESE SHEETS WOULD BE
 24X36 AND SHOULD BE PRINTED OUT AT THAT SIZE FOR
 INSPECTORS TO USE AT THE SITE.
 A. PLEASE UPDATE PAPER SIZE THAT THE SCALE MATCHES. I
 CANNOT SCALE OFF OF THE PROVIDED SHEETS.
 B. DIMENSION CLEAR SPACE IN BAR AREA AROUND PREP TABLE.
 THIS TABLE APPEARS TO RESTRICT EGRESS FROM THAT AREA.
 C. PROVIDE DETAIL OF BAR CONSTRUCTION AND SPACE
 PROVIDED BELOW.
 D. SHOW CLEAR SPACE AT ADA BATHROOMS.
  
 1210.2.2 FBC[B] WALLS AND PARTITIONS. WALLS AND
 PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS AND
 WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT
 SURFACE, TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE
 FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE
 MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS
 NOT ADVERSELY AFFECTED BY MOISTURE.
 A. WHAT IS PROVIDED FOR WALL FINISH IN BATHROOMS AND
 ARE ANY OTHER FINISHES BEING PROVIDED?
 B. IS THERE AND DEMO TO SHOW OR EXISTING CONDITIONS?
 THE DOUBLE DOORS OPENING TO EXTERIOS SHOW ONE AS
 DASHED. IS THERE ANY WORK IN THIS AREA. IF NEW DOOR
 PLEASE PROVIDE PRODUCT APPROVAL, OR INDICATE THAT IT
 WILL BE A DEFERRED SUBMITTAL.
  
 2. 1006.2.1 FBC TABLE[B] SHEET LS102 MAXIMUM COMMON
 PATH OF EGRESS TRAVEL DISTANCE.
 -PLEASE STATE THE MAXIMUM COMMON PATH FROM TABLE
 1006.2.1. SHOW THE FULL DISTANCE OF TRAVEL TO THE
 EXTERIOR OF BUILDING SINCE THE EXIT STAIRS FROM
 MEZZANINE ARE NOT ENCLOSED.
  
 3. 505.2.1 FBC[B] AREA LIMITATION. THE AGGREGATE AREA
 OF A MEZZANINE OR MEZZANINES WITHIN A ROOM SHALL BE NOT
 GREATER THAN ONE-THIRD OF THE FLOOR AREA OF THAT ROOM
 OR SPACE IN WHICH THEY ARE LOCATED.
 THE CURRENT MEZZANINE DOESN?T MEET THE SIZE
 REQUIREMENTS FOR A MEZZANINE. THIS SHOULD BE CONSIDERED
 A 2 ND FLOOR.
 THE FLOOR OPENING IS ALLOWED PER 712.1.9 TWO-STORY
 OPENINGS.
 -PLEASE RENAME THIS LEVEL AND INCLUDE THE AREA IN AREA
 DATA SHEET G001.
  
 4. 226.1 FBC[A] THE ACCESSIBILITY CODE REQUIRES 0.05 %
 OF ALL SEATING TO BE ACCESSIBLE. WHERE DINING SURFACES
 ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT
 LEAST 0.05 PERCENT OF THE SEATING SPACES AND STANDING
 SPACES AT THE DINING SURFACES SHALL COMPLY WITH 902.
 -SHOW ON PLANS 0.05% OF SEATING TO COMPLY WITH 226.1
 AND 902 FOR THE BAR SEATING.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-05-29 Cont ID  
Sent By jpearson Date 2019-05-29 Time 07:58 Rev Time 0.00
Received By jpearson Date 2019-05-29 Time 07:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-04-23 Cont ID  
Sent By jpearson Date 2019-04-23 Time 11:11 Rev Time 0.00
Received By jpearson Date 2019-04-23 Time 11:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-02-07 Cont ID  
Sent By jpearson Date 2019-02-07 Time 11:17 Rev Time 0.00
Received By jpearson Date 2019-02-07 Time 11:17 Sent To  
Notes
2019-02-07 11:17:35CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ALL RECEPTACLE OUTLETS IN KITCHEN/FOOD PREP AREAS
 REQUIRE GFCI PROTECTION. PROVIDE CORRECTION. NEC 210.8
 2. PROVIDE DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC
 600.5; FBC EC 405.2.4
 3. PROVIDE SHOW WINDOW OUTLETS PER CODE. NEC 210.62
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-04-10 Cont ID  
Sent By scaldero Date 2019-04-10 Time 12:53 Rev Time 0.00
Received By scaldero Date 2019-04-10 Time 12:10 Sent To  
Notes
2019-04-10 12:53:30PERMIT #19010660
  
 APPROVED WITH COMMENTS:
  
 1) PER INFORMATION PROVIDED, THERE WILL NOT BE ANY OPEN
 FLAME COOKING OR USE OF GRILLS, BURNERS, HOT PLATES,
 ETC.
 COOKING OPERATIONS PRODUCING SMOKE OR GREASE-LADEN
 VAPORS SHALL BE PROTECTED WITH A CLASS I MECHANICAL
 EXHAUST HOOD EQUIPPED WITH AN AUTOMATIC WET-CHEMICAL
 FIRE SUPPRESSION SYSTEM.
 INSTALLATION AND USE OF THIS EQUIPMENT WILL REQUIRE A
 PERMIT.
  
 2) EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS
 SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A
 CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM.
 SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF
 OCCUPANTS PERMITTED FOR EACH ROOM.
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-01-25 Cont ID  
Sent By scaldero Date 2019-01-25 Time 12:36 Rev Time 0.00
Received By scaldero Date 2019-01-25 Time 11:10 Sent To  
Notes
2019-01-25 11:49:02PERMIT # 19010660
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1) PROVIDE THE COMMON PATH OF TRAVEL MEASUREMENTS FOR
 EACH AREA.
  
 2) THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY.
 INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE
 (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.3
 OF NFPA 101 FLORIDA EDITION 2015. FOR NON-SEPARATED
 MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE
 SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO
 THE BUILDING.
  
 3) NFPA 101, CH. 7 - 7.5.1.3.1: WHERE MORE THAN ONE
 EXIT, EXIT ACCESS, OR EXIT DISCHARGE IS REQUIRED FROM A
 BUILDING OR PORTION THEREOF, SUCH EXITS, EXIT ACCESSES,
 OR EXIT DISCHARGES SHALL BE REMOTELY LOCATED FROM EACH
 OTHER AND BE ARRANGED TO MINIMIZE THE POSSIBILITY THAT
 MORE THAN ONE HAS THE POTENTIAL TO BE BLOCKED
  
 4) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
  
 5) EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS
 SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A
 CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM.
 SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF
 OCCUPANTS PERMITTED FOR EACH ROOM.
  
 6) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE
 COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION
 SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS
 MAY BE GENERATED DURING PLAN RESUBMISSION.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-05-30 Cont ID  
Sent By shill Date 2019-05-30 Time 13:41 Rev Time 0.00
Received By shill Date 2019-05-10 Time 09:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-04-23 Time   Rev Time 0.00
Received By lmarchan Date 2019-04-04 Time 15:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-26 Cont ID  
Sent By shill Date 2019-02-26 Time 09:43 Rev Time 0.00
Received By shill Date 2019-01-18 Time 09:54 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-06-03 Cont ID  
Sent By lmarchan Date 2019-06-03 Time 10:26 Rev Time 0.00
Received By lmarchan Date 2019-04-09 Time 11:57 Sent To  
Notes
2019-06-03 10:27:12RECEIPT - 2019-0509-373 - $5,558.97 PAID
2019-04-09 11:57:50EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-01-25 Cont ID  
Sent By dbattles Date 2019-01-25 Time 10:00 Rev Time 0.00
Received By dbattles Date 2019-01-25 Time 10:00 Sent To  
Notes
2019-01-25 10:02:48UPON RE-SUBMITTAL WE WILL INFORM COUNTY THAT THE
 DIGITAL DRAWINGS ARE READY FOR PBC IMPACT REVIEW FOR
 CHANGE OF OCCUPANCY.
  
 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-05-30 Cont ID  
Sent By ccole Date 2019-05-30 Time 13:33 Rev Time 0.00
Received By ccole Date 2019-05-30 Time 11:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-04-19 Cont ID  
Sent By ccole Date 2019-04-19 Time 10:07 Rev Time 0.00
Received By ccole Date 2019-04-09 Time 14:40 Sent To  
Notes
2019-04-19 10:19:522ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19010660
 4/18/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE SUBMITTED SUMMARY AC CALCULATIONS MUST BE
 ELECTRONICALLY SIGNED AND SEALED BY THE FAE ENGINEER-
 SECTION C403.2.1 FBC EC.
  
 2) COMMENT #3 FROM THE 1ST REVIEW STILL EXISTS. PROVIDE
 A TYPE II EXHAUST HOOD FOR THE CONVECTION OVEN OR AN
 EXHAUST FAN SIZED AT .70 CFMS PER SQUARE FOOT- SEE
 SECTION 507.3 FBC M.
  
 3) COMMENT #6 PRINTED BELOW STILL EXISTS- PLEASE
 COMPLY.
  
 6) THE $5000.00 VALUE LISTED ON THE PERMIT APPLICATION
 APPEARS LOW FOR THE SCOPE OF WORK SHOWN ON THE PLANS.
 PLEASE SEE SECTION 109.3 WPB BELOW AND SUBMIT
 CONTRACTS, AND/OR INVOICES AND ESTIMATES TO VERIFY
 PROJECT COSTS.
  
 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-02-05 Cont ID  
Sent By ccole Date 2019-02-05 Time 16:13 Rev Time 0.00
Received By ccole Date 2019-02-05 Time 16:02 Sent To  
Notes
2019-02-05 17:06:311ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19010660
 2/5/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A202: THE VENTILATION CALCULATIONS ARE NOT IN
 COMPLIANCE WITH TABLE 403.3.1.1 FBC M.
  
 A) THE FOOD SERVICE AREA (DINING ROOM) CALCULATION IS
 BASED ON A ZONE POPULATION OF 70 PERSONS PER 1000 SF AT
 7.5 CFMS PERSON- (68 PERSONS X 7.5 CFMS= 510 CFMS ) + (
 0.18 CFMS PER SF.= 168 CFMS). TOTAL CFMS- 510 + 168 =
 678 CFMS.
  
 B) THE RETAIL/GALLERY AREA CALCULATION IS 40 PERSONS
 PER 1000 SF. AT 7.5 CFMS PER PERSON- (48 PERSONS X 7.5
 CFMS= 353 CFMS) + (0.06 PER SF= 71). TOTAL CFMS- 353 +
 71 = 424 CFMS.
  
 NOT INCLUDED IN THE CALCULATION IS THE SECOND FLOOR
 MECHANICAL SPACE. PLEASE CLARIFY THE USE OF SUCH A
 LARGE SPACE FOR THE MINIMAL AMOUNT OF MECHANICAL
 EQUIPMENT SHOWN ON THE PLAN SHOWN THERE, AND CORRECT
 THE TABLE TO INCLUDE THE ACCURATE CALULATIONS FOR ALL
 AREAS OF THE FACILITY.
  
 2) SHEET A201 & A202: BASED ON THE INCREASED OCCUPANT
 LOAD FOR THE TENANT SPACE, AND INCREASED HEAT GAIN FROM
 LIGHTING, PEOPLE, APPLIANCES ETC, PLEASE PROVIDE AC
 CALCULATIONS TO VERIFY THE EXISTING SYSTEMS ARE CAPABLE
 OF CONDITIONING AND DEHUMIDIFYING THE SPACE AS
 REQUIRED- SECTIONS C403.2.1 AND C403.2.2 FBC EC.
  
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE NEW
 CONVECTION OVEN AND PANINI PRESS. IT IS ASSUMED AT THE
 TIME OF THIS REVIEW THAT AT A MINIMUM, A TYPE II
 EXHAUST HOOD FOR THE OVEN IS REQUIRED, UNLESS THE
 COOKING PROCESS PRODUCES GREASE OR SMOKE- SEE SECTIONS
 507.2 & 507.3 FBC M. PLEASE NOTE THAT SEPARATE PERMITS
 ARE REQUIRED FOR KITCHEN HOODS AND FIRE SUPPRESSION
 SYSTEMS.
  
 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE NEW
 DISHWASHER AND PROVIDE A TYPE II EXHAUST HOOD FOR THE
 APPLIANCE- SECTION 507.2.
  
 5) SHEET A201: UNDER THE "DESCRIPTION OF FACILITY USE"
 PLEASE INDICATE WHAT FOOD ITEMS ARE COOKED AND SERVED
 AT THE FACILTIY. PLEASE INCLUDE A MENU IF AVAILABLE.
  
 6) THE $5000.00 VALUE LISTED ON THE PERMIT APPLICATION
 APPEARS LOW FOR THE SCOPE OF WORK SHOWN ON THE PLANS.
 PLEASE SEE SECTION 109.3 WPB BELOW AND SUBMIT
 CONTRACTS, AND/OR INVOICES AND ESTIMATES TO VERIFY
 PROJECT COSTS.
  
 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-05-15 Cont ID  
Sent By gjohnson Date 2019-05-15 Time 10:12 Rev Time 0.00
Received By gjohnson Date 2019-05-13 Time 18:35 Sent To  
Notes
2019-05-15 10:13:09PLUMBING PROVISO:
  
 SHALL COMPLY PRIOR TO 1ST ROUGH INSPECTION.
  
 1. PROVIDE FLOOR PLAN AND ISOMETRIC DRAWING FOR GREASE
 INTERCEPTOR AND CONNECTED FIXTURES. PER WPB AMEND TO
 FBC 107.3.5.1.3(13)
  
 2. PROVIDE INSTALLATION GUIDE FOR GREASE INTERCEPTOR.
 FBC PL 1002.4.1
  
 3. MOVABLE SINK SYSTEMS SHALL COMPLY WITH ASME
 A112.19.12. THE MANUFACTURE SPECIFICATIONS PROVIDED FOR
 THE HAND SINK AT THE BAR DO NOT COMPLY PLEASE PROVIDE
 SPECIFICATIONS THAT SHOW COMPLIANCE OR A SINK SYSTEM
 THAT DOES COMPLY. PER FBC PL 418.3
  
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-04-16 Cont ID  
Sent By gjohnson Date 2019-04-16 Time 09:29 Rev Time 0.00
Received By gjohnson Date 2019-04-16 Time 08:26 Sent To  
Notes
2019-04-16 09:48:001ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PROVIDE SIZING CALCULATIONS FOR GREASE INTERCEPTOR
 INCLUDE ALL FIXTURE REQUIRED TO DISCHARGE THROUGH
 INTERCEPTOR 3 COMPARTMENT SINK MOP SINK ANY OTHER SINK
 RECEIVING GREASE WASTE. PER FBC PL 1003.2
  
 2. PLACE NOTE ON THE PLAN AN AS-BUILD DRAWING OF PIPING
 FOR GREASE INTERCEPTOR AND CONNECTED SINKS. PER WPB
 AMEND TO FBC 107.2.1
  
 3. PROVIDE MANUFACTURE SPECIFICATIONS OF SELF CONTAINED
 SINK AT BAR. PER WPB AMEND TO FBC 107.2.1 AND SHALL
 COMPLY WITH FBC PL 418.3 MOVABLE SINK SYSTEMS.MOVABLE
 SINK SYSTEMS SHALL COMPLY WITH ASME A112.19.12.
  
 4. SEE COMMENTS FROM BUILDING AND PROVIDE COMPLETE
 DIMENSIONS OF THE BATHROOMS TO VERIFY COMPLIANCE WITH
 FBC ACC CH 6 PER FBC EX 806.1 GENERAL.A BUILDING,
 FACILITY, OR ELEMENT THAT IS ALTERED SHALL COMPLY WITH
 THE PROVISIONS OF THE FLORIDA BUILDING CODE,
 ACCESSIBILITY.
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-02-06 Cont ID  
Sent By gjohnson Date 2019-02-06 Time 08:41 Rev Time 0.00
Received By gjohnson Date 2019-01-31 Time 17:36 Sent To  
Notes
2019-01-31 17:39:491ST REVIEW: 19010660
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE PLUMBING FLOOR PLAN CLEARLY SHOWING
 SCOPE OF PLUMBING WORK BEING DONE AND LOCATION OF WATER
 HEATER. PER WPB AMEND TO FBC 107.2.1
  
 2. PROVIDE A WATER AND SANITARY ISOMETRIC DRAWING FOR
 AREA BETWEEN BATHROOMS AND THE BAR AREA.PER WPB AMEND
 TO FBC 107.3.5.1.3(13)
  
 3. A GREASE INTERCEPTOR IS REQUIRED FOR THE MOP SINK
 FLOOR SINK AND BAR AREA. PER FBC PL 1003.3.1
  
 4. PLEASE PROVIDE PRICE BREAK DOWN FOR WORK BEING DONE
 TO INCREASE ACCESSIBILITY TO COMPLY WITH FBC ACC
 202.4.1 DISPROPORTIONATE COST.
  
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
  
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-05-14 Cont ID  
Sent By dbattles Date 2019-05-14 Time 08:35 Rev Time 0.00
Received By dbattles Date 2019-05-14 Time 08:35 Sent To  
Notes
2019-05-14 08:37:48IF ANY ADDITIONAL SHEETS ADDED THEY WILL NEED TO BE
 REVIEWED FOR DIGITAL SIGNATURE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-04-10 Cont ID  
Sent By dbattles Date 2019-04-10 Time 07:49 Rev Time 0.00
Received By dbattles Date 2019-04-10 Time 07:49 Sent To  
Notes
2019-04-10 08:44:08OK - FIRST REVIEW - NEW SHEETS WILL NEED TO BE
 DIGITALLY SIGNED.
2019-04-10 07:49:477 SHEETS - OK

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-01-25 Cont ID  
Sent By dbattles Date 2019-01-25 Time 10:02 Rev Time 0.00
Received By dbattles Date 2019-01-24 Time 15:02 Sent To  
Notes
2019-01-25 10:04:05ALL SHEETS - OK
 ANY NEW SHEETS PROVIDED FOR 2ND REVIEW WILL NEED TO BE
 CHECKED FOR DIGITAL SIGNATURE.
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2019-05-23 Cont ID  
Sent By elevesqu Date 2019-05-23 Time 09:38 Rev Time 0.00
Received By elevesqu Date 2019-05-23 Time 09:38 Sent To  
Notes
2019-05-23 09:45:14ZONING PROVISO:
 RETAIL/MERCANTILE COMPONENT NEEDS TO BE ADDED TO BTR
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-04-10 Cont ID  
Sent By aaponte Date 2019-04-10 Time 15:25 Rev Time 0.00
Received By aaponte Date 2019-04-10 Time 15:25 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-02-26 Cont ID  
Sent By aaponte Date 2019-02-26 Time 08:45 Rev Time 0.00
Received By aaponte Date 2019-02-26 Time 08:45 Sent To  
Notes
***NONE***