Plan Review Details - Permit 19010610
Plan Review Stops For Permit 19010610
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-01-31 Cont ID  
Sent By gjohnson Date 2019-01-31 Time 14:07 Rev Time 0.00
Received By gjohnson Date 2019-01-31 Time 14:07 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-01-22 Cont ID  
Sent By gjohnson Date 2019-01-22 Time 06:41 Rev Time 0.00
Received By gjohnson Date 2019-01-22 Time 06:41 Sent To  
Notes
2019-01-22 07:41:05 
  
 1ST REVIEW: 19010610
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE INDICATE WHICH MODELS ARE BEING USED FOR THE
 GENERATOR AND POLL HEATER. PER WPB AMEND TO FBC 107.2.1
  
 2. SHOW DISTANCE OF TANKLESS WATER HEATER FROM ANY
 OPENINGS IN THE BUILDING PROVIDE MANUFACTURE
 INSTALLATION GUIDE TO VERIFY DISTANCE. PER WPB AMEND TO
 FBC
  
 3. PE PIPING TO BBQ GRILL IS RUNNING UNDER THE
 STRUCTURE THIS IS PROHIBITED. PER FBC FG 404.17.1
  
 4. LABEL THE TYPE OF PIPING ON TH RISER, SHOW THE
 LENGTH OF EACH SECTION. PIPE PER 2017 FBC-FUEL GAS,
 SECS. 402.4.1, 402.4.2. OR 2017 FBC-R SEC. G2413.4.1,
 G2413.4.2. WPB AMEND TO FBC 107.2.1
  
 5. PROVIDE THE TOTAL LONGEST LENGTH FROM METER TO COOK
 TOP WHEN I ROUGHLY SCALED IT I CAME UP WITH 240' AT
 THIS LENGTH THE FIRST SECTION OF PIPE SHALL BE 1' PER
 FBC FG TABLE 402.4(22)
  
 6. PROVIDE A REVISED SHEET SP1 THE ONE IN THE SUBMITTAL
 SHOWS THE ADDITION OF THE MASTER BEDROOM THE APPROVED
 PLANS HAVE THE ADDITION REMOVED. PER WPB AMEND TO FBC
 107.2.1
  
 7. ALL REVISED PLAN SHEETS SHALL BE SIGNED AND SEALED
 BY DESIGNER OF RECORD. PER
 PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-31 Cont ID  
Sent By gjohnson Date 2019-01-31 Time 14:07 Rev Time 0.00
Received By gjohnson Date 2019-01-29 Time 15:41 Sent To  
Notes
2019-01-30 15:41:36RESUB ROUTED TO GJOHNSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-22 Cont ID  
Sent By gjohnson Date 2019-01-22 Time 07:41 Rev Time 0.00
Received By gjohnson Date 2019-01-16 Time 15:26 Sent To  
Notes
2019-01-17 15:26:17REVISION ROUTED TO GJOHNSON