Plan Review Details - Permit 19010587
| Plan Review Stops For Permit 19010587 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-02-21 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-21 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-21 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-12 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-12 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2019-02-12 15:24:29 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE INFILLS ARE SUBJECT TO WIND LOADS, AN ENGINEER | | | MUST DESIGN THE INFILL OPENINGS. FS 471.003.2.A.C.(I), | | | | | | 2. PLEASE SUBMITT AN ENGINEERED DESIGN PER FBC 2104; | | | TMS602/ACI 530 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-28 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-28 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-28 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2019-01-28 17:28:01 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLEASE PROVIDE STRUCTURAL DETAILS TO CLOSE THE | | | OPENINGS WITH CMU BLOCK AND STUCCO. FBC 107 | | | | | | 2. PLEASE PROVIDE PLASTER APPLICATION DETAILS PER FBC | | | 2510; FBC 2512 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-02-20 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-02-20 |
Time |
16:28 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-01-25 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-25 |
Time |
09:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-21 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-21 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-19 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2019-02-20 15:41:47 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-12 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-11 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2019-02-12 09:42:39 | RESUB ROUTED TO JDUPREY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-28 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-28 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-15 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-01-16 16:10:21 | ROUTED TO HISTORIC INBOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy