Plan Review Details - Permit 19010528
| Plan Review Stops For Permit 19010528 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-02-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-24 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-24 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-04 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-04 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2019-02-04 11:02:52 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | | | 1. FBC B 107 PROVIDE THE N.O.A./PRODUCT APPROVAL FOR | | | THE ANGLED MULLION BARS TO BE INSTALLED AT THE FRONT | | | BAY WINDOW. | | | | | | 2. FBC R 310.2.1 (EMERGENCY ESCAPE MINIMUM OPENING | | | SIZE) THIS CODE REQUIREMENT FOR THE BED ROOM WINDOW | | | HEIGHTS WILL NOT COMPLY WITH OUT THE EXCEPTION FROM THE | | | EXISTING BUILDING CODE, (SEE ITEM #3 BELOW). | | | | | | 3. FBC EB 702.5 (EMERGENCY ESCAPE AND RESCUE OPENINGS) | | | PROVIDE AN EXISTING FLOOR PLAN SHOWING THE BED ROOM | | | WINDOWS TO BE CHANGED OUT ARE THE SAME TYPE (SINGLE | | | HUNG) THAT WILL BE REPLACED WITH, IN ORDER TO MEET THIS | | | CODE EXCEPTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-24 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-07 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-04 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-01-15 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-04 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-04 |
Time |
10:40 |
Sent To |
|
|
| Notes |
|
|
|