Plan Review Details - Permit 19010525
| Plan Review Stops For Permit 19010525 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-16 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2019-05-09 10:27:44 | CHANGED TO RES REMODEL AS IS A TWO UNIT BUILDING. | | | VERIFY VALUE IS CORRECT. SEE 5K ON ELECTRICAL | | | APPLICATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-02-12 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-02-12 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2019-02-12 14:13:57 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19010525 | | | ADD: 919 2ND ST. | | | CONT: INGECO CONTRACTORS LLC | | | TEL: 561-315-3819 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. FEB. 12/2019 | | | ACTION: DENIED | | | | | | 1) PLEASE ASK FOR A RECORDS RESEARCH REQUEST FOR THIS | | | PROPERTY. IT WOULD APPEAR THAT THIS BUILDING MAY HAVE | | | BEEN CONVERTED FROM A 2 UNIT TO A 4 UNIT APARTMENT | | | BUILDING WITHOUT A PERMIT. CONTACT CRAIG MCPHERSON FOR | | | A RECORDS RESEARCH REQUEST BE COMPLETED FOR THIS | | | PROPERTY. MR. MCPHERSON CONTACT NUMBER IS 561-805-6684. | | | | | | IT ALSO APPEARS THAT THERE HAS NEVER BEEN A RENTAL | | | LICENSE FOR THIS PROPERTY, NEITHER FOR 2 UNITS OR 4 | | | UNITS. WE HAVE RESEARCHED THIS BY ADDRESS AS WELL AS BY | | | PCN. | | | IN REVIEWING THE CITY RECORDS (GREEN CARDS) FOR 919 2ND | | | ST. IT WAS BUILT AS AN APT. / DUPLEX. THE GREEN CARD | | | WAS CREATED IN 11/08/62. | | | | | | 2017 EXISTING BUILDING CODE LEVEL II 801.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. CREATION OR EXTENSION | | | OF NONCONFORMITY. ALL NEW WORK, RE-CONFIGURATION SHALL | | | NOT CREATE OR EXTEND ANY NONCONFORMITY IN THE EXISTING | | | BUILDING TO WHICH THE RE-CONFIGURATION OF SPACE IS | | | BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL | | | STRENGTH, FIRE SAFETY, MEANS OF EGRESS, OR THE CAPACITY | | | OF MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS. | | | | | | 2) THE ONLY SHEET SUBMITTED IS AN ELECTRICAL SHEET E1 | | | IN THE BOTTOM CENTER THERE IS WHAT APPEARS TO BE A | | | CONCEPTUAL DRAWING OF STAIR LAYOUT. THERE IS NOT ENOUGH | | | INFORMATION ON THIS SHEET TO DO A REVIEW. THERE IS A | | | NOTE THAT STATES THE RISERS ARE TO BE MAXIMUM OF 8 | | | INCHES AND THE MINIMUM OF 6.75 INCHES. | | | PLEASE REVIEW THE 2017 FBC-B 1011.5.2 1011.5.2 RISER | | | HEIGHT AND TREAD DEPTH. STAIR RISER HEIGHTS SHALL BE 7 | | | INCHES MAXIMUM AND 4 INCHES MINIMUM. | | | | | | 3) THERE IS A 2ND NOTE THAT INDICATES SEE DETAIL 2 | | | SHEET S-1. THERE IS NO SHEET S-1 ATTACHED. 107.2.1.2 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | THE DESIGNER OF RECORD HAS NOT INDICATED TO WHAT CODE | | | THE STAIRS WERE DESIGNED TO, TO WHAT LIVE LOAD, TYPE OF | | | MATERIAL FOR THE SUPPORTING STRINGERS, SPECIES, GRADE | | | OR SIZE OF THE TIMBERS, HOW MANY STRINGERS THERE WILL | | | BE OR HOW MANY THE VERTICAL UPRIGHTS AND SPACING, NO | | | INFORMATION ON THE LANDING AND THE HANDRAIL GUARDRAIL | | | SYSTEMS. MISSING ANCHORS FOR WIND AND THE WIND DESIGN | | | CRITERIA. | | | | | | 5) PLEASE ALSO BE AWARE OF THE CODE VIOLATION OF THE | | | WINDOWS WITHIN 10 FEET OF THE STAIR. 2017 FBC-B 1027.6 | | | EXTERIOR EXIT STAIRWAY AND RAMP PROTECTION. EXTERIOR | | | EXIT STAIRWAYS AND RAMPS SHALL BE SEPARATED FROM THE | | | INTERIOR OF THE BUILDING AS REQUIRED IN SECTION 1023.2. | | | OPENINGS SHALL BE LIMITED TO THOSE NECESSARY FOR EGRESS | | | FROM NORMALLY OCCUPIED SPACES. WHERE A VERTICAL PLANE | | | PROJECTING FROM THE EDGE OF AN EXTERIOR EXIT STAIRWAY | | | OR RAMP AND LANDINGS IS EXPOSED BY OTHER PARTS OF THE | | | BUILDING AT AN ANGLE OF LESS THAN 180 DEGREES THE | | | EXTERIOR WALL SHALL BE RATED IN ACCORDANCE WITH SECTION | | | 1023.7. | | | 1023.7 INTERIOR EXIT STAIRWAY AND RAMP EXTERIOR WALLS. | | | EXTERIOR WALLS OF THE INTERIOR EXIT STAIRWAY OR RAMP | | | SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 705 FOR | | | EXTERIOR WALLS. WHERE NONRATED WALLS OR UNPROTECTED | | | OPENINGS ENCLOSE THE EXTERIOR OF THE STAIRWAY OR RAMPS | | | AND THE WALLS OR OPENINGS ARE EXPOSED BY OTHER PARTS OF | | | THE BUILDING AT AN ANGLE OF LESS THAN 180 DEGREES, THE | | | BUILDING EXTERIOR WALLS WITHIN 10 FEET (3048 MM) | | | HORIZONTALLY OF A NONRATED WALL OR UNPROTECTED OPENING | | | SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 | | | HOUR. OPENINGS WITHIN SUCH EXTERIOR WALLS SHALL BE | | | PROTECTED BY OPENING PROTECTIVES HAVING A FIRE | | | PROTECTION RATING OF NOT LESS THAN 3/4 HOUR. THIS | | | CONSTRUCTION SHALL EXTEND VERTICALLY FROM THE GROUND TO | | | A POINT 10 FEET ABOVE THE TOPMOST LANDING OF THE | | | STAIRWAY OR RAMP, OR TO THE ROOF LINE, WHICHEVER IS | | | LOWER. | | | | | | 6) MINIMUM STAIRWAY WIDTH SEE 2017 FBC-B 1011.2 WIDTH | | | AND CAPACITY. THE REQUIRED CAPACITY OF STAIRWAYS SHALL | | | BE DETERMINED AS SPECIFIED IN SECTION 1005.1, BUT THE | | | MINIMUM WIDTH SHALL BE NOT LESS THAN 44 INCHES. SEE | | | SECTION 1009 FOR ACCESSIBLE MEANS OF EGRESS STAIRWAYS. | | | EXCEPTIONS: 1.STAIRWAYS SERVING AN OCCUPANT LOAD OF | | | LESS THAN 50 SHALL HAVE A WIDTH OF NOT LESS THAN 36 | | | INCHES. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-07-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-09 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-09 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-06-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-07 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-07 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2019-06-07 13:44:22 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: 3RD REVIEW, DENIED, SEE | | | COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 (NOT PROVIDED.) | | | 2. CORRECTED. | | | 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. THE LOAD CALCULATION PROVIDED IS THE TYPE | | | PERMITTED FOR A SINGLE DWELLING UNIT. NEC 220 (LOAD | | | CALCULATION STILL NOT CORRECT. WATER HEATER DOES NOT | | | MATCH WHAT IS SHOWN IN PANEL SCHEDULE, MATH IS NOT | | | CORRECT, BUILDING LOAD SHOWS A WASHER/DRYER BUT THIS IS | | | NOT SHOWN ON PLAN OR IN PANEL SCHEDULES, AND SHOULD BE | | | INCLUDED IN THE LOAD CALCULATION FOR WHICHEVER PANEL IT | | | IS FED FROM. PROVIDE ACCURATE LOAD CALCULATION.) | | | 4. PROVIDE ACCURATE RISER DIAGRAM. RISER SHOWS ONE | | | SERVICE ENTRANCE TO A METER CAN, BUT THE NOTE SAYS THIS | | | IS 4 METER CANS. PROVIDE CLARIFICATION AND CORRECTIONS | | | AS NEEDED. 4 METER CANS CANNOT FEED ONE DISCONNECT. NEC | | | 215.5; WPB FBC 107.2.1 (NOT CORRECTED. RISER DOES NOT | | | MATCH WHAT IS SHOWN ON PLAN.) | | | 5. SERVICE DROP IS SHOWN TO BE SUPPLIED BY FPL. IF THIS | | | CHANGES, A REVISION TO THE PLAN WILL BE NECESSARY. WPB | | | FBC 107.2.1 | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10 | | | (DEFERRED SUBMITTAL ACCEPTED.) | | | 9. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANELS. | | | NEC 110.3, 110.9 (NOT PROVIDED.) | | | 10. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR | | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4 (ONLY ONE PANEL SCHEDULE WAS PROVIDED. | | | THERE ARE MULTIPLE PANELS. PROVIDE FOR EACH.)(3RD | | | REVIEW: THE PANEL SCHEDULES PROVIDED DO NOT MATCH WHAT | | | IS SHOWN ON FLOOR PLAN. WHERE IS THE PANEL SCHEDULE FOR | | | THE OUTSIDE METER/MAIN? ARE ANY ITEMS FED FROM THIS?) | | | 11. CORRECTED. | | | 12. CORRECTED. | | | 13. RISER DIAGRAM AND PLAN HAS SEVERAL DISCREPANCIES AS | | | TO PANEL SIZE. SOME AREAS SHOW 100 AMP PANELS, ANOTHER | | | AREA SHOWS 125 AMP PANELS, ANOTHER SHOWS 150 AMP | | | PANELS, AND ONE SHOWS A 200 AMP PANEL. CORRECT | | | DISCREAPNCIES. WPB FBC 107.2.1 (PLAN AND RISER STILL DO | | | NOT MATCH.) | | | | | | NEW COMMENTS: | | | | | | 14. FOR EACH DWELLING UNIT OF A MULTIFAMILY DWELLING | | | WHERE THE DWELLING UNIT IS LOCATED AT GRADE LEVEL AND | | | PROVIDED WITH INDIVIDUAL EXTERIOR ENTRANCE/EGRESS, AT | | | LEAST ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM | | | GRADE AND NOT MORE THAN 2.0 M (61?2 FT) ABOVE GRADE | | | LEVEL SHALL BE INSTALLED. PROVIDE CORRECTION. NEC | | | 210.52(E)(2) | | | 15. SHOW LOCATION ON PLAN OF A/C UNITS AND PROVIDE A | | | GFCI PROTECTED RECEPTACLE OUTLET FOR SERVICING OF A/C | | | EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC | | | 210.63; FBC RE E3901.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-15 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-15 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2019-05-15 13:13:00 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 (NOT PROVIDED.) | | | 2. CORRECTED. | | | 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. THE LOAD CALCULATION PROVIDED IS THE TYPE | | | PERMITTED FOR A SINGLE DWELLING UNIT. NEC 220 (NOT | | | CORRECT. THERE ARE TWO LOAD CALCULATIONS, BUT THEY ARE | | | IDENTICAL AND BOTH MARKED UNIT 1. THERE IS NO LOAD | | | CALCULATION FOR THE ENTIRE SERVICE.) | | | 4. PROVIDE ACCURATE RISER DIAGRAM. RISER SHOWS ONE | | | SERVICE ENTRANCE TO A METER CAN, BUT THE NOTE SAYS THIS | | | IS 4 METER CANS. PROVIDE CLARIFICATION AND CORRECTIONS | | | AS NEEDED. 4 METER CANS CANNOT FEED ONE DISCONNECT. NEC | | | 215.5; WPB FBC 107.2.1 (NOT CORRECTED. RISER SHOWS ONE | | | METER WITH 2 PANELS, BUT THE PLAN SHOWS AT LEAST 3 | | | PANELS. CORRECT DISCREPANCIES.) | | | 5. WIRE SIZE SHOWN IN SERVICE DROP IS NOT ADEQUATELY | | | SIZED TO HANDLE THE LOAD STATED. PROVIDE CORRECTION. | | | NEC 310.15(B)(16) (NOT CORRECTED.) | | | 6. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1(NOT PROVIDED.) | | | 7. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 | | | AS APPLICABLE. (NOT PROVIDED.) | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10 (NOT | | | PROVIDED.) | | | 9. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANELS. | | | NEC 110.3, 110.9 (NOT PROVIDED.) | | | 10. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR | | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4 (ONLY ONE PANEL SCHEDULE WAS PROVIDED. | | | THERE ARE MULTIPLE PANELS. PROVIDE FOR EACH.) | | | 11. NOTE STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12 (NOT CORRECTED.) | | | | | | NEW COMMENTS: | | | | | | 12. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94 | | | 13. RISER DIAGRAM AND PLAN HAS SEVERAL DISCREPANCIES AS | | | TO PANEL SIZE. SOME AREAS SHOW 100 AMP PANELS, ANOTHER | | | AREA SHOWS 125 AMP PANELS, ANOTHER SHOWS 150 AMP | | | PANELS, AND ONE SHOWS A 200 AMP PANEL. CORRECT | | | DISCREAPNCIES. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-02-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-21 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-21 |
Time |
15:50 |
Sent To |
I |
|
| Notes |
| 2019-02-21 15:48:39 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | 2. A FULL REVIEW IS NOT POSSIBLE UNTIL BUILDING AND | | | ZONING COMMENTS ARE SATISFACTORILY ADDRESSED. WPB FBC | | | 107.2.1 | | | 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. THE LOAD CALCULATION PROVIDED IS THE TYPE | | | PERMITTED FOR A SINGLE DWELLING UNIT. NEC 220 | | | 4. PROVIDE ACCURATE RISER DIAGRAM. RISER SHOWS ONE | | | SERVICE ENTRANCE TO A METER CAN, BUT THE NOTE SAYS THIS | | | IS 4 METER CANS. PROVIDE CLARIFICATION AND CORRECTIONS | | | AS NEEDED. 4 METER CANS CANNOT FEED ONE DISCONNECT. NEC | | | 215.5; WPB FBC 107.2.1 | | | 5. WIRE SIZE SHOWN IN SERVICE DROP IS NOT ADEQUATELY | | | SIZED TO HANDLE THE LOAD STATED. PROVIDE CORRECTION. | | | NEC 310.15(B)(16) | | | 6. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 7. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 | | | AS APPLICABLE. | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10 | | | 9. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANELS. | | | NEC 110.3, 110.9 | | | 10. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR | | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4 | | | 11. NOTE STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2019-05-09 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2019-05-09 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2019-05-09 10:29:39 | THIS IS A TWO FAMILY STRUCTURE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-01-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-01-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-01-31 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2019-02-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-02-01 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-02-01 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-07-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-09 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-06-28 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2019-07-01 12:41:52 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-06-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-31 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2019-06-03 14:30:45 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-30 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2019-05-09 10:49:16 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 5/9/19 EL | | 2019-05-01 15:36:19 | B14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-02-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2019-01-29 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2019-02-05 15:01:34 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 2/5/2019 EL | | 2019-01-29 16:45:16 | B14 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-13 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-13 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2019-05-13 14:03:47 | NO PLUMBING SHOWN ON PLAN. | | | PLANS AND PERMIT REQUIRED FOR ANY PLUMBING WORK. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-05-09 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-05-09 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-02-05 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-02-04 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2019-02-05 15:01:15 | PROPERTY RECORD SEARCH FOUND THAT ONLY TWO UNITS WERE | | | LEGALLY CREATED IN THIS BUILDING. | | | | | | PLEASE PERFORM PROPERTY SEARCH TO SEE IF THERE ARE ANY | | | LEGAL RECORDS OF 4 UNITS AND RESUBMIT. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |