| Plan Review Stops For Permit 19010515 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-16 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-04-16 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-03-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-12 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-12 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2019-03-12 09:42:22 | PROVISO/REDLINE: | | | FBC B 2509.2, MATERIALS USED FOR A BASE FOR TILE SHALL | | | COMPLY WITH TABLE B 2509.2 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-18 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-18 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-05 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-02-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-01-31 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-18 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-03 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-03-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-20 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-02-20 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-29 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-21 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-21 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-18 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-18 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-03-21 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-03-20 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2019-03-21 06:26:56 | 1) SHT. A 2.1.1 - DETAIL #12 - THE SHOWER FLOOR SHALL | | | BE PITCHED A MINIMUM OF 1/4 INCH PER FOOT TO THE DRAIN | | | PER THE 2017 FBC-PLUMBING SEC. 417.5.2. | | | 2) SHT. A 3.02 - DETAILS #2 & #3 - THE OUTLET OF THE | | | TOILET PAPER DDISPENSER SHALL BE LOCATED 19 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOOR, NOT TWO FEET AS SHOWN. | | | 2017 FBC-ACCESS. SEC.604.9.6. | | | 3) SHT. A 3.02 - DETAIL #3 - THE TOILET PAPER DISPENSER | | | SHALL BE LOCATED A MINIMUM OF 7 INCHES AND A AMXIMUM OF | | | 9 INCHES FROM THE FRONT OF THE TOILET BOWL TO THE | | | CENTERLINE OF THE TOILET PAPER DISPENSER.2017 | | | FBC-ACCESS. SEC. 604.9.6. | | | 4) SHT. A 3.02 - DETAIL #3 - THE SEAT HEIGHT OF A WATER | | | CLOSET ABOVE THE FINISH FLOOR SHALL BE 17 INCHES | | | MINIMUM AND 19 INCHES MAXIMUM MEASURED TO THE TOP OF | | | THE SEAT. THE DETAIL APPEARS TO SHOW THE MEASUREMNT TO | | | THE TOP OF THE TOILET BOWL. | | | 5) SHT. A 3.02 - DETAIL #3 - THE GRAB BAR IN THE SHOWER | | | SHALL BE LOCATED A MAXIMUM OF 6 INCHES FROM ADJACENT | | | WALLS PER 2017 FBC-ACCESS. SEC.608.3.2. THE DETAIL | | | SHOWS 9 INCHES ON ONE SIDE OF THE GRAB BAR. ALSO, SHOW | | | THE HEIGHT OF THE GRAB BARS IN THE SHOWER. | | | 6) SHT. P 4.1 - THE PLANS CALL OUT A HUB DRAIN BELOW | | | THE LAVATORY. WHAT WILL BE DISCHARGING INTO THIS HUB | | | DRAIN? HOW WILL THE TRAP SEAL BE MAINTAINED IN THE TRAP | | | TO PREVENT SEWER GASES FROM ENTERING THE STRUCTURE? | | | CLARIFY. | | | 7) NOTE ON THE PLAN OR SHOW ON THE WATER ISOMETRIC THAT | | | A BACKFLOW PREVENTER WILL BE INSTALLED ON THE WATER | | | FILTER,REFRIGERATOR ICEMAKER, AND THE COFFEE MAKER. | | | 2017 FBC-PLUMBING SEC. 608.3, 608.16.10. | | | 8) SHT. A 3.02 - DETAIL #2 - SHOWS THE WATER CLOSET AT | | | 1 FOOT 5 INCHES TO THE CENTERLINE OF THE TOILET WHICH | | | WOULD MAKE THE GRAB BAR 5 INCHES FROM THE ADJACENT | | | WALL, NOT 6 INCHES AS SHOWN TO COMPLY WITH 2017 | | | FBC-ACCESS. SEC.504.5.2. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-02-20 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-02-20 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2019-02-20 08:30:22 | | | | 1ST REVIEW: 19010515 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE PRIVATE BATHROOM DOES NOT MEET THE EXEMPTION FOR | | | A SINGLE OCCUPANT ACCESSED ONLY THROUGH A PRIVATE | | | OFFICE IT SHALL MEET ALL THE REQUIREMENTS OF THE FBC | | | ACC CH 6 | | | 2. THE SHOWER DIMENSIONS SHALL COMPLY WITH ONE OF THE | | | FOLLOWING FBC ACC 608.2.1, 608.2.2, 608.2.3 | | | 3. THE CONTROLS SHALL COMPLY WITH THE REQUIREMENTS OF | | | THE TYPE OF SHOWER. FBC ACC 608.5.1, 608.5.2, 608.5.3 | | | 4. PLEASE NOTE ON THE PLAN OR SHOW ON WATER ISOMETRIC A | | | BACKFLOW IS REQUIRED ON THE WATER FILTER , REFRIGERATOR | | | ICE MAKER AND COFFEE MAKER .PER FBC PL 608.3, 608.16.10 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-18 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-16 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2019-04-16 11:32:32 | BUILDING - OK |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-03-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-12 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-12 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2019-03-12 09:56:34 | PROVISO: NEW PAGES SUBMITTED NEXT REVIEW CYCLE REQUIRE | | | VERIFICATION | | | |
|
|