Plan Review Details - Permit 19010507
Plan Review Stops For Permit 19010507
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-03-12 Cont ID  
Sent By pvalenti Date 2019-03-12 Time 06:27 Rev Time 0.00
Received By pvalenti Date 2019-03-11 Time 16:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-30 Cont ID  
Sent By jwitmer Date 2019-01-30 Time 07:02 Rev Time 0.00
Received By jwitmer Date 2019-01-29 Time 13:57 Sent To  
Notes
2019-01-30 07:02:012017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19010507
 ADD: 4631 N. CONGRESS AVE. SUITE: 101
 CONT: CONENGINEERS BUILDERS LLC
 TEL: 954-849-7322
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JAN. 30/ 2019
 ACTION: DENIED
  
 1) THE LIFE SAFETY SHEET DOES NOT PROVIDE ANY OF THE
 CODE REQUIREMENTS AS TO WHAT CODE THE PLANS WERE
 CREATED, NOR DOES THE PLAN INDICATE UNDER THE EXISTING
 BUILDING CODE WHICH METHOD THE PLANS WERE DEVELOPED NOR
 DOES THE PLAN INDICATE ANY OF THE BUILDING CRITERIA.
  
 1A) THE 2017 FBC-B WAS ADOPTED STATEWIDE ON DEC.
 30/2017.
  
 1B) THE 2017 FBC-EXISTING BUILDING CODE SECTION 301.1.
 THE REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION
 OR RELOCATION OF ALL EXISTING BUILDINGS SHALL COMPLY
 WITH ONE OF THE METHODS LISTED IN SECTIONS 301.1.1
 THROUGH 301.1.3 AS SELECTED BY THE APPLICANT. SECTIONS
 301.1.1 THROUGH 301.1.3 SHALL NOT BE APPLIED IN
 COMBINATION WITH EACH OTHER.
  
 1C) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING:
 1C)(2.) MINIMUM TYPE OF CONSTRUCTION SHALL BE
 DETERMINED (SEE SECTION 503).
 1C)(3.) IS THE BUILDING FIRE SPRINKLERED OR NOT? IT
 APPEARS THAT TRAVEL DISTANCES WERE TAKEN FOR SPRINKLERS
 W/ TABLE 1006.2.1. NO FIRE SPRINKLER PLANS WERE FILED
 WITH THIS PERMIT?
  
 2) SHEET 013 A1.12 THE DIMENSION PLAN IT APPEARS THAT
 THE RESTROOM 114 AND OFFICE 113 BOTH ARE MISSING THE
 WIDTH AND LENGTH OF THE ROOMS, THE TELCO ROOM 115 AND
 STORAGE ROOM 112 ARE MISSING THE WIDTH OF THE ROOMS.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED TO BE ABLE
 TO BUILD THE WALLS WITHOUT DIMENSIONS.
  
 3) SHEET 020-A5.51 MILLWORK DETAILS DETAIL NUMBER 2
 INDICATES THE BREAKROOM COUNTER TOP AND SINK, WHAT THE
 PLAN DOES NOT PROVIDE IS AT WHAT HEIGHT THE COUNTER TOP
 OR SINK IS. THE PLAN STATES REFER TO PLANS. SHEET
 012-A1.11 DOES SHOW WHERE TO FIND DETAILS FOR THE
 RECEPTIONIST DESK, EXAM ROOM SINKS BUT THERE IS NO
 DETAIL OR CUT SECTION FOR THE BREAK ROOM SINK. PLEASE
 SHOW COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE
 SECTION:
 606.3HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-02-07 Cont ID  
Sent By jpearson Date 2019-02-07 Time 08:07 Rev Time 0.00
Received By jpearson Date 2019-02-07 Time 08:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-01-18 Cont ID  
Sent By scaldero Date 2019-01-18 Time 10:06 Rev Time 0.00
Received By scaldero Date 2019-01-18 Time 09:52 Sent To  
Notes
2019-01-18 10:06:34PERMIT # 19010507
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 APPROVED PROVISO:
  
 1) SHEET A0.15 - REFERENCE IS MADE REGARDING THE
 ADDITION OF MAGLOCKS ON THE MAIN ENTRY DOOR. PLEASE
 REVIEW AND ENSURE COMPLIANCE WITH ANY AND ALL
 APPLICABLE REQUIREMENTS AS OUTLINED IN NFPA 101,
 CHAPTER 7.
  
 2) A SEPARATE PERMIT WILL BE REQUIRED IF
 ACCESS-CONTROLLED EGRESS WILL BE INSTALLED.
  
 3) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
  
 4) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-05-30 Cont ID  
Sent By tklarge Date 2019-05-30 Time 08:05 Rev Time 0.00
Received By tklarge Date 2019-05-30 Time 08:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-12 Cont ID  
Sent By pvalenti Date 2019-03-12 Time 06:30 Rev Time 0.00
Received By pvalenti Date 2019-02-22 Time 07:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-02-07 Time   Rev Time 0.00
Received By lmarchan Date 2019-01-17 Time 16:48 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-01-30 Cont ID  
Sent By jwitmer Date 2019-01-30 Time 07:02 Rev Time 0.00
Received By jwitmer Date 2019-01-29 Time 13:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-02-05 Cont ID  
Sent By ccole Date 2019-02-05 Time 13:12 Rev Time 0.00
Received By ccole Date 2019-02-05 Time 13:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-05-30 Cont ID  
Sent By tklarge Date 2019-05-30 Time 08:04 Rev Time 0.00
Received By tklarge Date 2019-05-30 Time 08:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-01-31 Cont ID  
Sent By gjohnson Date 2019-01-31 Time 14:48 Rev Time 0.00
Received By gjohnson Date 2019-01-31 Time 14:48 Sent To  
Notes
2019-01-31 15:06:55PROVISO
  
 1. THE BREAK ROOM SINK SHALL COMPLY WITH FBC ACC 606.2,
 606.3
  
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-03-12 Cont ID  
Sent By pvalenti Date 2019-03-12 Time 06:30 Rev Time 0.00
Received By pvalenti Date 2019-03-12 Time 06:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-02-07 Cont ID  
Sent By jpearson Date 2019-02-07 Time 07:37 Rev Time 0.00
Received By jpearson Date 2019-02-07 Time 07:37 Sent To  
Notes
2019-02-07 07:37:09ALL SHEETS OK FOR THIS SUBMISSION. ANY SHEETS SUBMITTED
 FOR NEXT REVIEW WILL NEED TO BE CHECKED FOR SIGNATURE.
 WPB FBC 107.1
  
  
2019-02-05 14:09:33MECH PLANS OK

Review Stop Z ZONING
Rev No 2 Status P Date 2019-03-11 Cont ID  
Sent By llouie Date 2019-03-11 Time   Rev Time 0.00
Received By llouie Date 2019-03-11 Time   Sent To  
Notes
2019-03-11 14:05:30* INTERIOR MODIFICATIONS ONLY.
  
 * ZONE: CSPD (WEST PALM HOSPITAL FKA COLUMBIA HOSPITAL)
  
 * REFERENCE: PB 1223

Review Stop Z ZONING
Rev No 1 Status F Date 2019-01-31 Cont ID  
Sent By llouie Date 2019-01-31 Time   Rev Time  
Received By llouie Date 2019-01-31 Time   Sent To  
Notes
2019-01-31 15:49:07** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) PLEASE CLARIFY THE SCOPE OF WORK (I.E.
 INTERIOR/EXTERIOR MODIFICATIONS, CHANGE OF USE, ADDING
 SQUARE FOOTAGE, ETC.). THIS PROPERTY IS ZONED COMMUNITY
 SERVICE PLANNED DEVELOPMENT (CSPD) AND MAY TRIGGER A
 MINOR/MAJOR AMENDMENT TO THE CSPD.
  
 2.) WHAT IS THE EXISTING USE WITHIN THE BUILDING? SHOW
 THE CHANGES FROM THE EXISTING SPACE TO THE PROPOSED
 SPACE (I.E. DEMO PLAN).
  
 3.) SURVEY OF THE PROPERTY IS MISSING FROM THE PERMIT
 APPLICATION. PLEASE PROVIDE.
  
 NOTES:
  
 * REVISION MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: CSPD (WEST PALM HOSPITAL FKA COLUMBIA HOSPITAL)
  
 * REFERENCE: PB 1223
  
  