| 2019-01-29 13:54:37 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19010462 |
| | ADD: 2529 OKEECHOBEE BLVD. / CHECKERS RESTAURANT |
| | CONT: AEC SERVICES INC. |
| | TEL: 561-684-1234 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. JAN. 29/ 2019 |
| | ACTION: DENIED |
| | |
| | 1) SHEET 1 ESEALED FOR 2529 OKEECHOBEE PLEASE NOTE IF |
| | SUBMITTED PLAN REPRESENTS THE ACTUAL PARKING SPACES |
| | ALLOTTED TO CHECKERS THERE ARE MORE THAN 25 PARKING |
| | SPACES, THIS PLAN SHOWS 53 PARKING SPACES, WHERE TABLE |
| | 208.2 OF THE 2017 FBC-ACCESSIBILITY CODE WOULD REQUIRE |
| | 3 ACCESSIBLE PARKING SPACES. PLEASE NOTE WITH MULTIPLE |
| | SPACES YOU CANNOT WHEEL BEHIND OTHER ACCESSIBLE PARKING |
| | SPACES. |
| | |
| | 2) SHEET 2 ESEALED FOR 2529 OKEECHOBEE. THE SUBMITTED |
| | PLAN FOR THE PROPOSED CROSSWALKS AND ACCESS AISLE DO |
| | SHOW ELEVATION CHANGES FOR THE CROSS WALK BUT THE |
| | ACCESSIBLE PARKING SPACE AND ACCESS AISLE DOES NOT |
| | PROVIDE THE ELEVATION TAGS TO BE ABLE TO SHOW THE |
| | ACCESS AISLE AND PARKING SPACE MEET THE REQUIREMENTS |
| | FOUND IN THE 2017 FBC-ACCESSIBILITY CODE SECTION FOR |
| | CROSS SLOPES FOR: |
| | |
| | 2A) CROSS SLOPES FOR RAMPS 405.3 CROSS SLOPE. CROSS |
| | SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48. |
| | |
| | 2B) PARKING SPACES & ACCESS AISLES: 502.4 FLOOR OR |
| | GROUND SURFACES. PARKING SPACES AND ACCESS AISLES |
| | SERVING THEM SHALL COMPLY WITH 302. ACCESS AISLES SHALL |
| | BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. |
| | CHANGES IN LEVEL ARE NOT PERMITTED. |
| | EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE |
| | PERMITTED. |
| | |
| | 3) SHEET 2 OF THE ESEALED PLANS DOES SHOW DIAGONAL |
| | STRIPED ACCESS AISLE. SHEET 3 ESEALED SHOW A 96 INCH |
| | WIDE ACCESSIBLE PARKING SPACE AND 60 INCH WIDE ACCESS |
| | AISLE. PLEASE NOTE THESE DETAILS MAY MEET THE FEDERAL |
| | ADA CODE, BUT THEY DO NOT MEET THE FLORIDA |
| | ACCESSIBILITY CODE. THE DEPARTMENT HAS APPROVED THE |
| | FLORIDA ACCESSIBILITY CODE SINCE IT IS A MORE STRINGENT |
| | CODE THAN THE ADA. PLEASE ALSO NOTE THIS DETAIL IS A |
| | SINGLE STRIPE, PLEASE REVIEW THE CITY MUNICIPAL CODE |
| | SECTION MUNI CODE ARTICLE XV PARKING, 94-485 FOR THE |
| | DIMENSIONS OF AN ACCESSIBLE PARKING SPACE, ACCESS AISLE |
| | AND COLORS EACH ARE TO BE PAINTED. |
| | |
| | 502.3.3 MARKING. ACCESS AISLES SHALL BE MARKED SO AS TO |
| | DISCOURAGE PARKING IN THEM. THE ACCESS AISLE MUST BE |
| | STRIPED DIAGONALLY TO DESIGNATE IT AS A NO-PARKING |
| | ZONE. |
| | ADVISORY 502.3.3 MARKING. THE METHOD AND COLOR OF |
| | MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT MAY |
| | BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS. |
| | BECAUSE THESE REQUIREMENTS PERMIT THE VAN ACCESS AISLE |
| | TO BE AS WIDE AS A PARKING SPACE, IT IS IMPORTANT THAT |
| | THE AISLE BE CLEARLY MARKED. |
| | FLORIDA LAW, S.553.5041 (5)(C)1., REQUIRES DIAGONAL |
| | STRIPING OF ACCESS AISLES. |
| | |
| | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |