| Plan Review Stops For Permit 19010393 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-03 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-03 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-04 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-04 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2019-06-04 15:49:25 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING PLAN 3RD REVIEW DENIED: | | | | | | PENDING ITEMS FROM ORIGINAL LIST: | | | | | | 2. IS STILL PENDING: THE TYPE OF CONSTRUCTION (TYPE | | | III-A) ENTERED ON PAGE A-1 UNDER CODE SUMMARY IS | | | INCORRECT. PROVIDE THE RIGHT BUILDING TYPE, SHOULD BE | | | TYPE I-A. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-08 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-08 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2019-05-08 14:48:54 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING 2ND REVIEW DENIED: | | | | | | 1. OK | | | 2. FAIL, SHEET A-1 UNDER CODE SUMMARY BUILDING CODE 2.4 | | | LEVELS OF ALTERATION - LEVEL III ALTERATION IS | | | INCORRECT. | | | PLEASE NOTE, THIS IS A NEW HIGHRISE BUILDING WITH THE | | | 1ST FLOOR BEING BUILT AS A SHELL SPACE, THIS IS NOT TO | | | BE REVIEWED UNDER THE EXISTING BUILDING CODE, SINCE | | | THIS WILL BE THE FIRST OCCUPANCY FOR THIS SPACE. | | | 3. OK | | | 4. FAIL, SHEET A-1 UNDER DESIGN WIND PRESSURES | | | (NEGATIVE PRESSURE), NEEDS TO BE CLEARLY ADDED TO | | | REVISED PLAN. | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | 9. WHEN RESUBMITTING PLANS, PLEASE INDICATE THE | | | REVISION AND REMOVE ANY VOIDED SHEETS AND REPLACE AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OFTHE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-01-22 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-01-22 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2019-01-22 14:18:28 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19010393 | | | ADD: 333 FERN ST. SUITE: 118 | | | CONT: BELA VISTA CONTRACTORS, INC. | | | TEL: 9544-644-3121 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. JAN. 22 / 2019 | | | ACTION: DENIED | | | | | | 1) SHEET A-1 AT THE TOP PORTION OF THIS SHEET THE SCOPE | | | OF WORK LIST THE ADDRESS OF 7070 SEMINOLE PRATT WHITNEY | | | ROAD SUITE # 2 LOXAHATCHEE, FL. THE BOTTOM HALF OF THE | | | SHEET UNDER THE HEADING OF GENERAL NOTES LIST THE | | | PROJECT LOCATED AT 333 FERN ST. WEST PALM BEACH, FL. | | | THE PERMIT APPLICATION ALSO LIST THE | | | ADDRESS OF 333 FERN ST. SUITE # 118. DISCREPANCY IN THE | | | LOCATION OF WHERE THE WORK IS TO BE COMPLETED UNDER | | | THIS PERMIT. 7070 SEMINOLE PRATT WHITNEY ROAD SUITE # 2 | | | LOXAHATCHEE, FL. IS NOT IN THE CITY LIMITS. | | | 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2) SHEET A-1 UNDER THE HEADING CODE SUMMARY 1.0 | | | APPLICABLE CODES: | | | APPLICABLE CODES 1.1 LIST THE ALTERATION AS A LEVEL II | | | ALTERATION, WHEREAS UNDER THE NOTE 2.4 THE LEVEL OF THE | | | ALTERATION AS A LEVEL III ALTERATION. DISCREPANCY IN | | | LEVEL OF ALTERATION, 107.2.1.2. ADDITIONAL INFORMATION | | | IS REQUIRED. PLEASE NOTE THIS IS A NEW HIGHRISE | | | BUILDING WITH THE 1ST FLOOR BEING BUILT AS SHELL SPACE, | | | THIS IS NOT TO BE REVIEWED UNDER THE EXISTING BUILDING | | | CODE, SINCE WILL BE 1ST OCCUPANCY FOR THIS SPACE!!! | | | | | | 3) SHEET A-1 UNDER THE HEADING BUILDING CODE LIST THIS | | | BUILDING AS CONSTRUCTION TYPE III- UNPROTECTED/ | | | UNSPRINKLERED. PLEASE STOP BY THE JOBSITE, THIS IS A 20 | | | STORY HIGHRISE BUILDING, PLEASE CORRECT THE BUILDING | | | TYPE AND THE BUILDING IS FIRE SPRINKLERED. 107.2.1.2. | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) SHEET A-1 THE WIND DESIGN INFORMATION GIVEN IS THE | | | EXISTING BUILDING IS, THAN 19 FEET TALL, PLEASE | | | CORRECT. THIS IS A 20 STORY HIGHRISE BUILDING. PLEASE | | | ALSO CORRECT THE NEGATIVE PRESSURES, THEY ARE TAKEN | | | FROM THE ROOF LEVEL, SEE ASCE 7-10, CHAPTER 30. | | | | | | 5) SHEET A-5 LIST THE TOILET ACCESSORY SCHEDULE UNDER | | | THE 2014 FBC. PLEASE NOTE THE 2017 FBC-ACCESSIBILITY | | | CODE WENT INTO EFFECT ON DECEMBER 31, 2017, STATEWIDE, | | | PLEASE UPDATE PLAN NOTES. | | | 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 6) SHEET A-2 IS THE DIMENSIONED FLOOR PLAN. PLEASE | | | REVIEW THE CORRIDOR THAT LEEDS TO THE ACCESSIBLE | | | RESTROOM. IT IS DIMENSIONED 3 FOOT 4 INCHES IN WIDTH. | | | PLEASE REVIEW THE 2017 FBC-ACCESSIBILITY CODE 404.2.3 | | | AND FIGURE 404.2.1(H) THAT REQUIRES THE CORRIDOR TO BE | | | 48 INCHES IN WIDTH. | | | | | | 7) SHEET A-2 DOES NOT INDICATE THE FRONT ENTRY DOOR IF | | | THE SIDEWALK IS THE SAME LEVEL AS THE FINISH FLOOR IN | | | THE INTERIOR, PLEASE SHOW COMPLIANCE WITH THE 22017 | | | FBC-ACCESSIBILITY CODE SECTION 402.2 COMPONENTS. | | | ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE | | | FOLLOWING COMPONENTS: WALKING SURFACES WITH A RUNNING | | | SLOPE NOT STEEPER THAN 1:20, DOORWAYS, RAMPS, CURB | | | RAMPS EXCLUDING THE FLARED SIDES, ELEVATORS, AND | | | PLATFORM LIFTS. ALL COMPONENTS OF AN ACCESSIBLE ROUTE | | | SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF | | | CHAPTER 4 AND 208.3.1. | | | | | | 8) IMPACT FEES- PAPER SUBMITTALS. PLANS REQUIRE REVIEW | | | BY THE PBC IMPACT FEE OFFICE. CALL (561) 233-5025. UPON | | | APPROVAL, YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO | | | THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED AND | | | WITH A COPY OF THE RECEIPT AS APPLICABLE. PLEASE | | | PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | THE PBC IMPACT FEE OFFICE. THE FORM CAN BE FOUND AT: HT | | | TP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTF | | | EES/FORMS/QUESTIONNAIRE.PDF | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-04-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-22 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-22 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-02-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-03 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-03 |
Time |
10:44 |
Sent To |
I |
|
| Notes |
| 2019-02-03 10:44:34 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | 2. NOTE ON PLAN STATES EMERGENCY AND EXIT LIGHTS ARE | | | REQUIRED TO BE FED FROM THE GENERAL LIGHTING CIRCUIT IN | | | THE AREA, BUT THE LIGHTING PLAN SHOWS THEM FED FROM | | | OTHER CIRCUITS. PROVIDE CORRECTION. NEC 700.12(F) | | | 3. PROVIDE SHOW WINDOW RECEPTACLE PER CODE. IT IS | | | LISTED IN PANEL SCHEDULE BUT NOT SHOWN ON PLAN. NEC | | | 210.62 | | | 4. SIGN CIRCUIT SHOWN ON PANEL SCHEDULE, BUT NOT ON | | | PLAN. PROVIDE CORRECTION. NEC 600.5; WPB FBC 107.2.1 | | | 5. RISER DIAGRAMS STATES THERE IS A 400 AMP SINGLE | | | PHASE PANEL THAT IS EXISTING. LIGHTING AND POWER PLAN | | | SHOW A 200 AMP PANEL EXISTING. PROVIDE CLARIFICATION | | | AND/OR CORRECTIONS. WPB FBC 107.2.1; NEC 215.5 | | | 6. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63 | | | 7. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. THREE PHASE LOADS WOULD NOT HAVE | | | ALL OF THE LOAD ON ONE PHASE AND NONE ON THE OTHERS. | | | LOAD CALCULATION SHOULD INCLUDE 100% OF NON-CONTINUOUS | | | LOADS AND 125% OF CONTINUOUS LOADS. NEC 215.2, 220, | | | 408.30 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-17 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2019-05-17 14:06:55 | 5/17/19 | | | | | | | | | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) FIRE ALARM WORK SHALL BE DONE UNDER SEPARATE PERMIT | | | AND SHOP DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-04-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-04-04 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2019-04-04 16:40:21 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) FIRE ALARM WORK SHALL BE DONE UNDER SEPARATE PERMIT | | | AND SHOP DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-01-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-01-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-01-18 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2019-01-18 12:57:41 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET A 1 - THERE ARE TWO SCOPES OF PROJECT | | | INDICATED, ONE STATES THE ADDRESS OF SEMINOLE PRATT | | | WHITNEY RD AND THE OTHER FERN ST. | | | | | | PLEASE REMOVE THE ONE THAT IS NOT APPLICABLE. | | | | | | | | | | | | 2) SHEET A 1 - UNDER SECTION 1.0 APPLICABLE CODES THERE | | | IS AN INCORRECT EDITION OF THE CURRENT FLORIDA FIRE | | | PREVENTION CODE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH | | | INCLUDES THE 2015 EDITIONS OF NFPA 1 AND NFPA 101. | | | | | | PLEASE CORRECT AND ENSURE COMPLIANCE. | | | | | | | | | | | | 3) SHEET A 1 - UNDER SECTION 2.0 BUILDING CODE, THERE | | | IS AN INDICATION OF TYPE 3 UNPROTECTED, UNSPRINKLERED. | | | ADDITIONALLY, ON SHEET A 3, THERE IS AN INDICATION NEXT | | | TO MAXIMUM TRAVEL DISTANCE TO EXIT 75' SPRINKLERED. | | | | | | IS THE BUILDING PROTECTED WITH FIRE SPRINKLERES? | | | | | | PLEASE REVIEW, CLARIFY AND OR CORRECT. | | | | | | IF SO, PLEASE PROVIDE A STATEMENT INDICATING SUCH AND | | | THAT ALL WORK OF THE FIRE SPRINKLER SYSTEM SHALL BE | | | UNDER SEPARATE SHOP DRAWINGS. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-03 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-26 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2019-06-27 16:21:57 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-06-11 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-15 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2019-06-10 16:30:44 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 6/11/2019 EL | | 2019-05-16 15:20:34 | B26 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-08 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-04-03 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2019-04-17 15:30:51 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 4/17/2019 EL | | 2019-04-04 10:58:44 | B29 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-02-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-11 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2019-01-16 14:10:55 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 1/16/19 EL | | 2019-01-11 14:04:24 | B10 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-08 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-08 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2019-05-08 13:59:39 | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | APPROVED | | | | | | RECEIVED COUNTY STAMPED PLANS AND RECEIPT. | | | TRACKING NUMBER MU-2019-008631-0000 | | | RECEIPT NUMBER 2019-0402-307 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-01-22 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-01-22 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2019-01-22 14:17:47 | IMPACT FEES- PAPER SUBMITTALS. PLANS REQUIRE REVIEW BY | | | THE PBC IMPACT FEE OFFICE. CALL (561) 233-5025. UPON | | | APPROVAL, YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO | | | THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED AND | | | WITH A COPY OF THE RECEIPT AS APPLICABLE. PLEASE | | | PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | THE PBC IMPACT FEE OFFICE. THE FORM CAN BE FOUND AT: HT | | | TP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTF | | | EES/FORMS/QUESTIONNAIRE.PDF | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-07-03 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-07-03 |
Time |
07:35 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-31 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-31 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2019-05-31 14:10:13 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19010393 | | | 5/31/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET ME-1: SHOW THE EXACT LOCATION OF THE AC | | | CONDENSER AND PROVIDE ENGINEERED DETAILS FOR | | | INSTALLATION- SECTIPON 301.15 FBC M. | | | | | | 2) ME-1: PROVDE A SEQUENCE OF OPERATION FOR THE OUTSIDE | | | AIR FAN. WILL THE FAN BE ELECTRICALLY LINKED WITH THE | | | AIR HANDLER FOR AUTOMATIC OPERATION? | | | | | | 3) ME-1: PROVIDE A CONDENSATE DISPOSAL PLAN- SECTION | | | 307.2.1 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-18 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-18 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2019-04-18 15:26:12 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19010393 | | | 4/18/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ME-1: THE OUTDOOR AIR TABLE IS INCORRECT. REFER TO | | | TABLE 403.3.1.1 FBC M: OUTDOOR AIR FOR FAST FOOD IS | | | CALCULATED AT 100 PERSONS PER 100 S.F. (23 PERSONS/7.5 | | | CFMS PER PERSON= 172.5 CFMS ) + (0.18 CFMS/232 SF.= 42) | | | = 215 CFMS OF OUTSIDE AIR REQUIRED. PLEASE CORRECT THE | | | TABLE THAT INDICATES 98.4 CFMS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-01-29 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-01-29 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2019-01-29 15:44:07 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19010393 | | | 1/29/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET ME-1: PROVIDE A SCOPE OF WORK OUTLINE ON THE | | | PLAN FOR CLARIFICATION. CURRENTLY THERE IS AN EQUIPMENT | | | SCHEDULE SHOWN FOR AN EXISTING 3.5 TON SYSTEM, HOWEVER | | | THE DUCT LAYOUT PLAN SHOWS A 2-TON SYSTEM. IS THE 3.5 | | | TON SYSTEM BEING REPLACED WITH A NEW 2-TON? | | | | | | 2) ME-1: SHOW HOW OUTSIDE AIR IS BEING PROVIDED AND | | | AUTOMATICALLY CONTROLLED AS REQUIRED BY SECTION 403.1 | | | FBC M, AND SECTION C403.2.4.3 FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-19 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-19 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-01-30 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-01-30 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2019-01-30 16:13:33 | | | | 1ST REVIEW: 19010393 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE TEMPERED WATER AT THE LAVATORY SHALL BE | | | DELINERED BY A TEMPERATURE LIMITING DEVICE CONFORMING | | | WITH ASSE 1070/ CSA B125.3.PER FBC PL 416.5 | | | | | | 2. PROVIDE WATER VALVES AT EACH DROP ON THE WATER | | | ISOMETRIC DRAWING. PER FBC PL 606.1(5) | | | | | | 3. THE HAND SINK CUP WASHER AND FLOOR DRAIN IN THE | | | EMPLOYEE SERVICE AREA SHALL BE CONNECTED TO GREASE | | | INTERCEPTOR.PER FBC PL 1003.3.1 | | | | | | 4. PROVIDE A GREASE TRAP SIZING CALCULATION FROM THE | | | MANUFACTURE FOR SCHIER YOU CAN CONTACT LEE SCHNEEWEISS | | | @ 1-800-538-4792 IT SHOULD INCUDE THE FLOOR SINK FOR | | | THE MIXER AND FLOOR SINK IN PREP ROOM AND THE FIXTURES | | | IN THE EMPLOYEE SERVICE AREA. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-04-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-19 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-19 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-06-10 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-06-10 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-06-10 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2019-06-10 16:30:27 | REPEAT PROVISO: SEPARATE OUTDOOR SEATING PERMIT | | | REQUIRED | | | NO LANDSCAPE MODIFICATIONS | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-04-17 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-04-17 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2019-04-17 15:30:37 | PROVISO: SEPARATE OUTDOOR SEATING PERMIT REQUIRED | | | NO LANDSCAPE MODIFICATIONS | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 | | 2019-04-17 10:11:08 | PROVISO: SEPARATE PERMIT REQUIRED FOR OUTDOOR SEATING. | | | NO LANDSCAPE MODIFICATIONS APPROVED. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-01-16 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-01-16 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-01-16 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2019-01-16 14:10:35 | PROVISO: | | | OUTDOOR SEATING REQUIRES SEPARATE PERMIT. | | | NO LANDSCAPE MODIFICATIONS. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|