Plan Review Details - Permit 19010315
Plan Review Stops For Permit 19010315
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-08-22 Cont ID  
Sent By jgomez Date 2019-08-22 Time 09:20 Rev Time 0.00
Received By jgomez Date 2019-08-21 Time 18:19 Sent To  
Notes
2019-08-22 09:20:17BUILDING REVIEW APPROVED WITH PROVISO (NO FEES)
 1-BEDROOM #2 EGRESS WINDOW SH34EH: PROVIDE
 MANUFACTURER'S CUT SHEETS TO VERIFY MIN. CLEAR
 OPENINGS. SEC. R310.2.1 FBC-RESIDENTIAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-06-27 Cont ID  
Sent By jgomez Date 2019-06-27 Time 13:26 Rev Time 0.00
Received By jgomez Date 2019-06-26 Time 18:51 Sent To  
Notes
2019-06-27 07:51:48NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***ENERGY CALCULATIONS NEED TO BE CERTIFIED BY THE
 OWNER PRIOR TO APPROVE THE BUILDING REVIEW.
  
  
  
 1- OK
  
 2- OK
  
 ORIGINAL COMMENT:
 3- PROVIDE ENERGY CALCULATIONS (2 COPIES). SEC. R101.5
 FBC-ENERGY CONSERVATION. NOTE: CALCULATIONS SUBMITTED
 ARE FOR ANOTHER ADDRESS (THEREFORE, THEY WERE NOT
 REVIEWED) AND TOO OLD. NEW CALCULATIONS FOR CORRECT
 ADDRESS AND WITH CURRENT CODE (2017).
  
 RESPONSE:
 A)THE ENERGY FORM R405-2017 IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM BY THE OWNER OR THE OWNER LEGALLY
 DESIGNATED AGENT PRIOR TO RECEIVE THE PERMIT AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 6TH EDITION (2017).
  
 B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING HOUSE ADDRESS AND BUILDER NAME. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C)REVISE ITEM #4 ON PAGE 1 OF 5. NUMBER OF BEDROOMS
 DOESN'T MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 D)REVISE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 5.
 MISSING WINDOWS ON THE SOUTH SIDE. THERE IS ONLY ONE
 WINDOW ON THE NORTH SIDE NOT 2. REVISE THE WINDOW
 OVERHANG DEPTH FOR WINDOW #7. SEE PLANS AND REVISE AS
 REQUIRED TO MATCH. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 E)TYPICALLY THE ATTIC VENT RATIO IS 1/150. PAGE 2 OF 5
 SPECIFIES 1/300. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS SHOWING COMPLIANCE WITH THE EXCEPTION OF
 SEC. R806.2 FBC-RESIDENTIAL WHEN SPECIFYING A VENT
 RATIO OF 1/300 AS SHOWN ON PAGE 2 OF 5. NOTE:
 COORDINATE WITH PLANS TO AVOID CONFLICTS/DELAYS.
  
 F) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND
 SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS
 ARE NOT USING THE DEFAULT FACTOR.
  
 4- OK.
  
 5- OK
  
 6- A)OK
  
 B)OK.
  
 7- OK
  
 8-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) OK.
  
 ORIGINAL COMMENT:
 B) PEEL AND STICK UNDERLAYMENT FOR SHINGLES AS
 SPECIFIED ON SHEET A5.
  
 RESPONSE:
 NO SUBMITTED.
  
 9-DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE
 PRODUCT APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 10- OK
  
 11- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR
 REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 12- BEDROOM #2 EGRESS WINDOW SH34EH: PROVIDE
 MANUFACTURER'S CUT SHEETS TO VERIFY MIN. CLEAR
 OPENINGS. SEC. R310.2.1 FBC-RESIDENTIAL.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-02-04 Cont ID  
Sent By jgomez Date 2019-02-04 Time 16:49 Rev Time 0.00
Received By jgomez Date 2019-02-04 Time 11:56 Sent To  
Notes
2019-02-04 16:50:59NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- PLEASE CONTACT MIKE ORIO CITY OF WEST PALM BEACH GIS
 SUPPORT SPECIALIST TO GET APPROVED ADDRESS.
 SEE CONTACT INFORMATION BELOW.
  
 CONTACT: MICHAEL ORIO GIS SUPPORT SPECIALIST/
 INFORMATION TECHNOLOGY
 TEL: 561-494-1040
 E-MAIL: [email protected]
  
 2- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 FBC R 401.3 (DRAINAGE)
 FBC 107.2.5 (SITE PLAN)
 FBC 110.9 (IMPACT OF CONSTRUCTION)
  
 3- PROVIDE ENERGY CALCULATIONS (2 COPIES). SEC. R101.5
 FBC-ENERGY CONSERVATION. NOTE: CALCULATIONS SUBMITTED
 ARE FOR ANOTHER ADDRESS (THEREFORE, THEY WERE NOT
 REVIEWED) AND TOO OLD. NEW CALCULATIONS FOR CORRECT
 ADDRESS AND WITH CURRENT CODE (2017)
  
 4- ARCHITECT OF RECORD TO SPECIFY ON PLANS INSULATION R
 VALUE FOR EXTERIOR WALLS, ADJACENT WALLS BETWEEN GARAGE
 AND A/C AREA AND CEILING AS REQUIRED BY SEC. R103.2
 FBC-ENERGY CONSERVATION.
 NOTE: ENERGY CALCULATIONS AND PLANS TO BE COORDINATED
 TO AVOID CONFLICTS/DELAYS.
  
 5- SOIL TEST REPORT SUBMITTED:
 A)REPORT SUBMITTED IS PRELIMINARY AND DOESN'T PROVIDE
 ENOUGH INFORMATION. SEE SEC. 1803.6 FBC AND PROVIDE
 COMPLETE REPORT SHOWING ALL THE RELEVANT INFORMATION.
 SOIL BEARING CAP CITY, SOIL PREPARATION, FOOTINGS
 RECOMMENDATION, EXPECTED SETTLEMENT, , ETC.
  
 B) PROVIDE REPORT WITH ENGINEER'S ORIGINAL SEAL AND
 SIGNATURE (2 COPIES) AS REQUIRED BY CHAPTER 471 F.S.
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
  
 6- A)DOORS AND WINDOWS DESIGN PRESSURES SHOWN ON THE
 EXTERIOR ELEVATIONS ON SHEET A5 DON'T CORRESPOND TO
 DESIGN PRESSURES FOR BUILDING EXPOSURE "C". REVISE AS
 REQUIRED. SEC. R301.2.1.4 FBC-RESIDENTIAL. NOTE:
 PROVIDE DESIGN PRESSURES BASED ON THE TRIBUTARY AREA
 AND END ZONE OR INTERIOR ZONE.
  
 B) REVISE ROOF AND WALL DESIGN PRESSURES SHOWN ON THE
 WIND LOAD SCHEDULE ON SHEET A3. THEY DON'T CORRESPOND
 TO A BUILDING IN EXPOSURE "C". REVISE AS REQUIRED. SEC.
 R301.2.1.4 FBC-RESIDENTIAL.
  
 7- NOTE #2 OF THE GENERAL NOTES AND NOTE #2 BELOW
 WINDOW SCHEDULE ARE REFERENCING THE 2014 FBC. THE
 CURRENT CODE IS THE 6TH EDITION 2017. UPDATE AS
 REQUIRED. SEC. 553 F.S.
  
 8-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) OVERHEAD GARAGE DOOR SIZE SPECIFIED ON PLANS.
  
 B) PEEL AND STICK UNDERLAYMENT FOR SHINGLES AS
 SPECIFIED ON SHEET A5.
  
 9-DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE
 PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 10- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATED TO $179,848. THE
 PERMIT FEE BALANCE IS $3713.47.
  
 11- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR
 REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-07-02 Cont ID  
Sent By jleahy Date 2019-07-02 Time 13:53 Rev Time 0.00
Received By jleahy Date 2019-07-02 Time 13:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-01-30 Cont ID  
Sent By jpearson Date 2019-01-30 Time 13:43 Rev Time 0.00
Received By jpearson Date 2019-01-30 Time 07:50 Sent To  
Notes
2019-01-30 13:43:25CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL SPECIFICATIONS #2, THE NEC AND FBC
 SPECIFIED FOR DESIGN IS NOT THE CURRENT CODE. PROVIDE
 CORRECTION. FBC PREFACE (ALSO SEE CURRENT CODES ABOVE)
 2. ELECTRICAL NOTE #1 AND ON FLOOR PLAN, AFCI
 PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL BRANCH
 CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND
 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS,
 DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
 BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902
 3. ELECTRICAL NOTE #15, NOTE STATES THAT LIGHTING IN
 CLOTHES CLOSETS SHALL COMPLY WITH NEC 4/10.B/D/1 THRU
 4, WHICH DOESN?T EXIST. PROVIDE CORRECTION. NEC 410.16;
 FBC RE E4003.12
 4. RISER DIAGRAM SHOWS THREE CONDUCTORS IN A CONDUIT
 FROM DISCONNECT TO INTERIOR PANEL. THEN IN A SEPARATE
 NOTE SHOWS A #6 EQUIPMENT GROUNDING CONDUCTOR TO PANEL.
 THIS METHOD OF INSTALLATION IS NOT PERMITTED, THE
 EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED WITH
 THE FEEDERS. PROVIDE CORRECTION. NEC 250.134(B); FBC RE
 E3908.9
 5. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A
 SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL
 GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN
 ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE
 EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS.
 NEC 250.53(A)(2); FBC RE E3608.4
 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 7. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE
 OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2
 8. PLAN SHOWS A SMOKE/CO ALARM TOO CLOSE TO BATHROOM
 DOOR. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET
 FROM BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3
 FEET FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC
 RE R314.3(4), NFPA 72:29.8.3.4
 9. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-22 Cont ID  
Sent By jgomez Date 2019-08-22 Time 17:42 Rev Time 0.00
Received By jgomez Date 2019-08-02 Time 12:30 Sent To I
Notes
2019-08-04 12:31:03R23

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-02 Cont ID  
Sent By jleahy Date 2019-07-02 Time 13:54 Rev Time 0.00
Received By jleahy Date 2019-06-10 Time 14:02 Sent To  
Notes
2019-06-18 10:33:00IF ALL OTHER REVIEWS PASS PLEASE RETURN TO PLB TO
 PROVISO PLAN. THUNT
2019-06-11 14:02:50R26

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-04 Cont ID  
Sent By jgomez Date 2019-02-04 Time 17:29 Rev Time 0.00
Received By jgomez Date 2019-01-09 Time 12:37 Sent To I
Notes
2019-01-10 12:37:22R13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2019-10-02 Cont ID  
Sent By cthroop Date 2019-10-02 Time 15:16 Rev Time 0.00
Received By cthroop Date 2019-10-02 Time 15:16 Sent To  
Notes
2019-10-02 15:17:41MU-2019-028588-0000. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2019-08-22 Cont ID  
Sent By jgomez Date 2019-08-22 Time 15:37 Rev Time 0.00
Received By jgomez Date 2019-08-22 Time 15:37 Sent To  
Notes
2019-08-22 15:37:55IMPACT FEES - PAPER SUBMITTALS
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-06-27 Cont ID  
Sent By jgomez Date 2019-06-27 Time 14:16 Rev Time 0.00
Received By jgomez Date 2019-06-27 Time 14:16 Sent To  
Notes
2019-06-27 14:16:38IMPACT FEES - PAPER SUBMITTALS
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-02-04 Cont ID  
Sent By jgomez Date 2019-02-04 Time 17:29 Rev Time 0.00
Received By jgomez Date 2019-02-04 Time 16:53 Sent To  
Notes
2019-02-04 17:29:43IMPACT FEES - PAPER SUBMITTALS
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-08-22 Cont ID  
Sent By jgomez Date 2019-08-22 Time 09:40 Rev Time 0.00
Received By jgomez Date 2019-08-22 Time 09:40 Sent To  
Notes
2019-08-22 09:44:25MECHANICAL REVIEW APPROVED WITH PROVISO:
 1- MASTER BEDROOM TRANSFER DUCT TO BE 9" MIN. SEC.
 M1602.3 FBC-RESIDENTIAL.
 2- REVISE MASTER BEDROOM TRANSFER DUCT LOCATION OR
 PROVIDE CALCULATIONS SHOWING HOW BEDROOM #2 WILL HANDLE
 THE MASTER BEDROOM AND BEDROOM #2 RETURN AIR. SEC.
 107.2.1.2 CITY AMENDMENTS.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-06-27 Cont ID  
Sent By jgomez Date 2019-06-27 Time 13:28 Rev Time 0.00
Received By jgomez Date 2019-06-27 Time 13:27 Sent To  
Notes
2019-06-27 13:50:31NEW SINGLE FAMILY RESIDENCE (R3) SECOND MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***ENERGY CALCUATIIONS NEED TO BE CERTIFIED BY THE
 OWNER PRIOR TO APPROVE THE MECHANICAL REVIEW.
  
  
 ORIGINAL COMMENT:
 1-PROVIDE COMPLETE MECHANICAL PLANS AND EQUIPMENT
 SIZING CALCULATIONS OR PROVIDE COMPLETE INFORMATION
 UNDER A SEPARATE APPLICATION. SEC. 107.5.3(11) CITY
 AMENDMENTS.
 NOTE:
 NO MECHANICAL PLANS WERE SUBMITTED AND THE EQUIPMENT
 SIZING CALCULATIONS SUBMITTED ARE FOR ANOTHER PROJECT.
  
 RESPONSE:
 A) EQUIPMENT SHOWN ON A/C PLAN PROVIDED DOESN'T MATCH
 EQUIPMENT LISTED ON THE LOAD CALCULATIONS SUBMITTED.
 REVISE AS REQUIRED TO MATCH. SEC. R403.7.1 FBC-ENERGY
 CONSERVATION.
 NOTE: ALSO COORDINATE WITH A/C SEER SHOWN ON THE ENERGY
 CALCULATIONS TO AVOID CONFLICTS/DELAYS.
  
 B) A/C PLAN SUBMITTED DOESN'T SHOW THE MAIN RETURN AIR
 OPENING. SEC. M1602.2 FBC-RESIDENTIAL. SPECIFY SIZE AND
 LOCATION
  
 C) CFM'S SHOWN ON THE A/C PLAN DON'T MATCH CFM'S SHOWN
 ON THE LOAD CALCULATIONS. REVISE AS REQUIRED TO MATCH.
 . SEC. R403.7.1 FBC-ENERGY CONSERVATION.
  
  
 2- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR
 REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-02-04 Cont ID  
Sent By jgomez Date 2019-02-04 Time 17:14 Rev Time 0.00
Received By jgomez Date 2019-02-04 Time 17:14 Sent To  
Notes
2019-02-04 17:28:19NEW SINGLE FAMILY RESIDENCE (R3) MECHANICAL REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1-PROVIDE COMPLETE MECHANICAL PLANS AND EQUIPMENT
 SIZING CALCULATIONS OR PROVIDE COMPLETE INFORMATION
 UNDER A SEPARATE APPLICATION. SEC. 107.5.3(11) CITY
 AMENDMENTS.
  
 NOTE:
 NO MECHANICAL PLANS WERE SUBMITTED AND THE EQUIPMENT
 SIZING CALCULATIONS SUBMITTED ARE FOR ANOTHER PROJECT.
  
 2- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR
 REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-08-22 Cont ID  
Sent By jgomez Date 2019-08-22 Time 15:38 Rev Time 0.00
Received By jgomez Date 2019-08-22 Time 15:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-06-18 Cont ID  
Sent By thunt Date 2019-06-18 Time 10:07 Rev Time 0.00
Received By thunt Date 2019-06-18 Time 10:07 Sent To  
Notes
2019-06-18 10:07:46PLUMBING 2ND REVIEW**DENIED**
  
 1) THE WASHING MACHINE SHALL BE MIN 3" TO THE BRANCH OR
 STACK. FBC P406.2
  
 2) BOTH BATHROOM ISOMETRIC SHOW 2 WET VENTED FIXTURE
 PAST THE VENT. ONLY 1 WET VENTED FIXTURE IS PERMITTED
 PAST BEYOND THE VENT. FBC-R P 3108.2.1
  
 3) ADD NOTE TO PLAN ALL HOT WATER PIPING SHALL BE
 INSULATED WITH MIN R-3 VALUE INSULATION. FBC-ENERGY
 R403.5.3
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-01-24 Cont ID  
Sent By jesmith Date 2019-01-24 Time 15:44 Rev Time 0.00
Received By jesmith Date 2019-01-24 Time 15:43 Sent To  
Notes
2019-01-24 15:44:47CODES IN EFFECT:
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 5TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 PLUMBING COMMENTS: DENIED
  
 1. RE: PLAN HEET A1; PLUMBING RISER.
 A. CONNECT EACH WATER CLOSET AND SHOWER FIXTURE DRAIN
 INDEPENDENTLY TO THE BATHROOM WET VENT IN BOTH
 BATHROOMS PER FBC RES P3108.1.
 B. PROVIDE A WATERSEAL TRAP FOR THE SHOWER, TUB AND
 WASHER PER FBC RES P3201.6.
 C. WASHER STANDPIPE SHALL NOT EXCEED 42' INLENGTH PER
 FBC RES P2706.1.2.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 SINCERELY,
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 561-805-6715
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2019-08-22 Cont ID  
Sent By jgomez Date 2019-08-22 Time 17:42 Rev Time 0.00
Received By jgomez Date 2019-08-22 Time 17:42 Sent To  
Notes
2019-08-22 17:42:26APPROVED:
 SHINGLES FL 18355-R4.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2019-06-27 Cont ID  
Sent By jgomez Date 2019-06-27 Time 11:20 Rev Time 0.00
Received By jgomez Date 2019-06-27 Time 11:20 Sent To  
Notes
2019-06-27 11:20:571--PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) PEEL AND STICK UNDERLAYMENT FOR SHINGLES AS
 SPECIFIED ON SHEET A5.
  
 APPROVED:
 SHINGLES FL 18355-R4.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-02-04 Cont ID  
Sent By jgomez Date 2019-02-04 Time 16:51 Rev Time 0.00
Received By jgomez Date 2019-02-04 Time 16:51 Sent To  
Notes
2019-02-04 16:52:551--PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) PEEL AND STICK UNDERLAYMENT FOR SHINGLES AS
 SPECIFIED ON SHEET A5.
  
 APPROVED:
 SHINGLES FL 18355-R4.

Review Stop Z ZONING
Rev No 3 Status P Date 2019-08-14 Cont ID  
Sent By awooten Date 2019-08-14 Time   Rev Time 0.00
Received By awooten Date 2019-08-14 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2019-06-20 Cont ID  
Sent By awooten Date 2019-06-20 Time   Rev Time 0.00
Received By awooten Date 2019-06-20 Time   Sent To  
Notes
2019-06-20 09:38:16*******************************ZONING REVIEW FAILED
 (REPEAT)************************
  
 PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION
 PERMIT. SHOWING THE FOLLOWING:
  
 RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
 SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
  
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
 ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
 ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISON
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2019-01-17 Cont ID  
Sent By awooten Date 2019-01-17 Time   Rev Time  
Received By awooten Date 2019-01-17 Time   Sent To  
Notes
2019-01-17 15:33:00********************************ZONING REVIEW
 FAILED**********************************
  
 DRIVEWAY, POOLS, FENCES, AND MECHANICAL EQUIPMENT
 REQUIRE A SEPARATE PERMIT.
  
 PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION
 PERMIT. SHOWING THE FOLLOWING:
  
 RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
 SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
  
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
 ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
 ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISON
 561-822-1449
 [email protected]