Plan Review Details - Permit 19010181
| Plan Review Stops For Permit 19010181 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-03 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-03 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2019-05-03 08:13:21 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | **ADDITIONAL COMMENTS** | | | | | | ALTERATIONS LEVEL 1 2 3 | | | | | | 1. PER THE MINIMUM PLAN REVIEW REQUIREMENTS FOUND IN | | | FBC 107, YOU MUST DECLARE THE CODE REFERENCE, | | | OCCUPANCY, OCCUPANCY LOAD AND LEVEL OF WORK. FOR YOUR | | | CONVENIENCE, THE APPLICABLE CODE IS: THE FBC 2017 6TH | | | EDITION EXISTING BUILDING. IT SEEMS THE LEVEL OF WORK | | | IS EITHER A REPAIR OR MORE LIKELY AN ALTERATION LEVEL | | | II. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-22 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-22 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-30 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-30 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2019-01-30 12:11:51 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PER PREVIOUS PERMIT DRAWINGS #14110788 IN FILE | | | APPEAR THAT ELECTRICAL AND PLUMBING WORK MUST BE | | | PERFORM. PLEASE PROVIDE A COMPREHENSIVE FLOOR PLAN | | | WHERE INDICATE ELECTRICAL OUTLETS, BATHROOM LOCATION, | | | DOOR LOCATIONS AND THE SCOPE OF WORK. FBC 107.3.5 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-02 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-02 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2019-05-02 15:49:51 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. LOAD CALCULATION USED IS THE TYPE PERMITTED FOR | | | RESIDENTIAL CALCULATIONS ONLY. PROVIDE ACCURATE LOAD | | | CALCULATION FOR SERVICE, INCLUDE EXISTING AND NEW LOADS | | | TO CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, | | | 220, 408.30 (LOAD CALCULATION STILL NOT CORRECT. THE | | | FIRST 10,000 VA AT 100% AND THE REMAINDER AT 50% | | | CALCULATION CAN ONLY BE USED FOR RECEPTACLE LOADS WHERE | | | THE LOAD ON THE RECEPTACLE IS 180 VA EACH. THE OTHER | | | EQUIPMENT THAT WAS INCLUDED IN THIS CALCULATION IS NOT | | | PERMITTED TO BE INCLUDED IN THE DEMAND FACTOR PORTION. | | | THIS EQUIPMENT SHOULD BE ADDED AT 100%. IF CORRECTED | | | LOAD CALCULATION EXCEEDS THE RATING OF THE ELECTRICAL | | | PANEL OR THE CONDUCTORS SUPPLYING THIS PANEL, PROVIDE | | | CORRECTIONS.) | | | 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. SIZE OF | | | SERVICE IS NOT CURRENTLY STATED ON PLAN. NEC 215.5; WPB | | | FBC 107.2.1 (NOT PROVIDED.) | | | 3. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-13 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-13 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2019-03-13 15:47:15 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. LOAD CALCULATION USED IS THE TYPE PERMITTED FOR | | | RESIDENTIAL CALCULATIONS ONLY. PROVIDE ACCURATE LOAD | | | CALCULATION FOR SERVICE, INCLUDE EXISTING AND NEW LOADS | | | TO CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, | | | 220, 408.30 | | | 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. SIZE OF | | | SERVICE IS NOT CURRENTLY STATED ON PLAN. NEC 215.5; WPB | | | FBC 107.2.1 | | | 3. ARE THERE CURRENTLY SHOW WINDOW OUTLES IN THIS | | | LOCATION? PROVIDE CLARIFICATION AND/OR CORRECTION. NEC | | | 210.62 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-04-26 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-04-26 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-02-26 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-02-26 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-03 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-04-19 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-22 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-21 |
Time |
13:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-30 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-07 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2019-01-08 14:38:04 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-04-24 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-24 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-24 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2019-04-24 11:22:07 | PLUMBING 2ND REVIEW**DENIED* | | | | | | CALLED AND DISCUSS WITH P.E OF RECORD JEFFEY FRIANT* | | | | | | PLEASE NOTE FL ST 553.80 (B)2B WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | IT IS RECOMMENDED FOR YOU TO COME IN AND MEET WITH THE | | | PLAN REVIEW STAFF BEFORE RESUBMITTING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | 1) COMMENT #1.NOT FULLY ANSWERED. PROVIDE HOW UNDER FBC | | | ACC YOU ARE PERMITTED TO REDUCE THE LEVEL OF | | | ACCESSIBILITY OF AN EXISTING CODE REQUIRED TOILET | | | COMPARTMENT AND USE ANOTHER UNIDENTIFIED TOILET ROOM? | | | FBC 107.2.1. ALL TOILET ROOMS PROVIDED SHALL COMPLY | | | WITH FBC ACC 603. FBC ACC 213.2. ANY AND ALL SHOWER | | | WHEN PROVIDED SHALL COMPLY WITH FBC ACC 608 | | | | | | 2) COMMENT #2. NO MANUFACTURER?S INSTALLATION MANUALS | | | HAVE BEEN PROVIDED IN THIS SUBMITTAL. YOU DO CALL OUT | | | MODEL ECO 11 IN YOUR RESPONSE BUT ON SHT. E1 PANEL | | | LISTING CALLS OUT ECO 8. PLEASE CLARIFY WITH ONE AND | | | PROVIDE INSTALLATION MANUAL WITH HEAT RISE CHARTS. FBC | | | 107.2.1 | | | | | | 3) COMMENT #3 ANSWERED | | | | | | 4) COMMENT #4 ANSWERED | | | | | | 5) COMMENT #5. NOT COMPLETED. YOUR PERMIT VALUE LISTED | | | IS $30,000. YOUR RESPONSE VALUATION LIST $40,000 BUT NO | | | CHANGE IN PERMIT VALUE COMPLETED. PROVIDE TO THE | | | BUILDING OFFICIAL HOW YOU CAME TO THIS VALUATION OR | | | PROVIDE BONA FIDE SIGN CONTRACT. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | | | | 6) COMMENT #6 WAS NOT ADDRESS AT ALL.(PROVIDE EXISTING | | | & CURRENT OCCUPANCY, OCCUPANT LOAD, AND LEVEL OF | | | ALTERATION) A COMPLETE AND THOROUGH REVIEW IS | | | IMPOSSIBLE TO PERFORM WITH OUT THIS INFORMATION. IF YOU | | | ARE COMBINING THE SEPARATE UNITS THAT WERE SEPARATED | | | UNDER PERMIT#14110788 THE OCCUPANT LOAD LISTED WAS 26 | | | TOTA FOR BOTH. YOU WILL BE REQUIRED TO PROVIDE A HI-LOW | | | DRINKING FOUNTAIN, MOP SINK, AND A TOILET COMPARTMENT | | | ROOM FOR BOTH MEN AND WOMEN AS THESE 2 UNITS EACH HAD | | | AN OCCUPANT LOAD 15 OR LESS AND NOW THE TOTAL LOAD | | | WOULD APPLY. FBC-PLUMBING 403.1, 403.2 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-13 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-13 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2019-03-13 10:45:42 | PLUMBING 1ST REVIEW**DENIED***3/13/19 | | | | | | 1) CITY RECORDS SHOW THE EXISTING BATHROOM UNDER PERMIT | | | #14110788 ACCESSIBILITY AND DOES NOT HAVE A SHOWER. IT | | | APPREARS WORK IN THIS SPACE WAS PERFORMED / STARTED | | | WITH OUT PERMITS AS CITIED ON 12/21/2018 FBC 105.1. THE | | | RESTOOM WILL HAVE TO FULLY COMPLY WITH CURRENT 2017 6TH | | | ED FBC-ACCESSIBILITY CODE CHAPTER 6. | | | | | | 2) PROVIDE MANUFACTURES SPEC/ INSTALLATION MANUAL FOR | | | THE WATER HEATER. FBC 107.3.5 | | | | | | 3) ANY AND ALL COVERED/ UNPERMITTED WORK SHALL BE | | | UNCOVERED, TESTED, AND APPROVED BY FIELD INSPECTOR. | | | | | | 4) SHT. P1 ISOMETRIC SHOW THE ENTIRE BATHROOM GROUP NOT | | | VENTED. PER FBC 901.2.1 AND OR DOES NOT MEET FBC 912.1 | | | HAVE MORE THEN 1 WET VENTED FIXTURE BEYOND THE VENT. | | | | | | 5) JOB VALVE. BY THE AMOUNT OF WORK ALREADY DONE AND | | | NOW WHAT IS REQUIRED THE BUILDING VALUE SEEMS LOW. | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATIONOF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOWDETAILED, QUANTITY | | | ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS (EXCLUDING | | | LAND VALUE) TO MEET THEAPPROVAL OF THE BUILDING | | | OFFICIAL. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALLBE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH,RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. | | | | | | 6) PROVIDE EXISTING & CURRENT OCCUPANCY AND OCCUPANT | | | LOAD. FBC 107.3.5 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | | | | SAMANTHA HILL | | | CHIEF PLANS EXAMINER | | | 561-805-6724 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-05-01 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-05-01 |
Time |
13:27 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-04-25 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-04-25 |
Time |
16:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-01-09 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-01-09 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-01-09 |
Time |
10:47 |
Sent To |
B |
|
| Notes |
|
|
|