Plan Review Details - Permit 19010025
| Plan Review Stops For Permit 19010025 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-01-14 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-01-14 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2019-01-14 12:08:16 | EXISTING BUILDING. INTERIOR WORK ONLY, NO MECHANICAL | | | WITHOUT PERMITS. | | | NEED SUBS FOR ELECTRIC AND PLUMBING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2019-01-08 10:16:10 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLAN SUBMITTED DOES NOT REPRESENT THE BUILDING | | | DESIGN AS REPRESENTED ON THE PROPERTY APPRAISERS | | | OFFICE. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | 2. PROVIDE PLAN THAT REPRESENTS STRUCTURE WITH ACCURATE | | | DEMENSIONS. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. REPEAT | | | COMMENT | | | | | | 3. DESIGNER TO PRINT NAME AND SIGN PLAN. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5) AND F.S. 481.229. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-01-14 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-01-14 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2019-01-08 11:22:34 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ELECTRICAL PERMIT REQUIRED | | | | | | 1. IF SCOPE OF WORK EXCEEDS THE REMOVAL OF FIXTURES | | | ONLY AND ANY WIRING SYSTEMS ARE ALTERED A WIRING RISER | | | DIAGRAHM WILL BE REQUIRED IN ADDITION TO A LOAD | | | CALCULATION FOR THE HOUSE. | | | | | | E3401.4 ADDITIONS AND ALTERATIONS. | | | ANY ADDITION OR ALTERATION TO AN EXISTING ELECTRICAL | | | SYSTEM SHALL BE MADE IN CONFORMITY TO THE PROVISIONS OF | | | CHAPTERS 34 THROUGH 43. WHERE ADDITIONS SUBJECT | | | PORTIONS OF EXISTING SYSTEMS TO LOADS EXCEEDING THOSE | | | PERMITTED HEREIN, SUCH PORTIONS SHALL BE MADE TO COMPLY | | | WITH CHAPTERS 34 THROUGH 43. | | | | | | E3403.2 INSPECTION REQUIRED. | | | NEW ELECTRICAL WORK AND PARTS OF EXISTING SYSTEMS | | | AFFECTED BY NEW WORK OR ALTERATIONS SHALL BE INSPECTED | | | BY THE BUILDING OFFICIAL TO ENSURE COMPLIANCE WITH THE | | | REQUIREMENTS OF CHAPTERS 34 THROUGH 43. | | | | | | E3403.3 LISTING AND LABELING. | | | ELECTRICAL MATERIALS, COMPONENTS, DEVICES, FIXTURES AND | | | EQUIPMENT SHALL BE LISTED FOR THE APPLICATION, SHALL | | | BEAR THE LABEL OF AN APPROVED AGENCY AND SHALL BE | | | INSTALLED, AND USED, OR BOTH, IN ACCORDANCE WITH THE | | | MANUFACTURER?S INSTALLATION INSTRUCTIONS. [110.3(B)] | | | | | | 2. PROVIDE SMOKE DETECTORS PER FBC R314. | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-02 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-01-14 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-01-14 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2019-01-08 10:19:52 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | MECHANICAL PERMIT REQUIRED | | | | | | 1. BASED ON THE SCOPE OF WORK WHICH INCLUDES THE | | | REMOVAL OF ALL DRYWALL THE AIR HANDLER UNIT (AHU) WILL | | | NEED TO BE REMOVED AND RE-INSTALLED BY A LICENSED | | | MECHANICAL CONTRACTOR. | | | | | | M1201.1 SCOPE. | | | THE PROVISIONS OF CHAPTERS 12 THROUGH 24 SHALL REGULATE | | | THE DESIGN, INSTALLATION, MAINTENANCE, ALTERATION AND | | | INSPECTION OF MECHANICAL SYSTEMS THAT ARE PERMANENTLY | | | INSTALLED AND USED TO CONTROL ENVIRONMENTAL CONDITIONS | | | WITHIN BUILDINGS. THESE CHAPTERS SHALL ALSO REGULATE | | | THOSE MECHANICAL SYSTEMS, SYSTEM COMPONENTS, EQUIPMENT | | | AND APPLIANCES SPECIFICALLY ADDRESSED IN THIS CODE. | | | | | | M1202.1 ADDITIONS, ALTERATIONS OR REPAIRS. | | | ADDITIONS, ALTERATIONS, RENOVATIONS OR REPAIRS TO A | | | MECHANICAL SYSTEM SHALL CONFORM TO THE REQUIREMENTS FOR | | | A NEW MECHANICAL SYSTEM WITHOUT REQUIRING THE EXISTING | | | MECHANICAL SYSTEM TO COMPLY WITH ALL OF THE | | | REQUIREMENTS OF THIS CODE. ADDITIONS, ALTERATIONS OR | | | REPAIRS SHALL NOT CAUSE AN EXISTING MECHANICAL SYSTEM | | | TO BECOME UNSAFE, HAZARDOUS OR OVERLOADED. MINOR | | | ADDITIONS, ALTERATIONS OR REPAIRS TO EXISTING | | | MECHANICAL SYSTEMS SHALL MEET THE PROVISIONS FOR NEW | | | CONSTRUCTION, UNLESS SUCH WORK IS DONE IN THE SAME | | | MANNER AND ARRANGEMENT AS WAS IN THE EXISTING SYSTEM, | | | IS NOT HAZARDOUS, AND IS APPROVED. | | | | | | M1202.3 MAINTENANCE. | | | MECHANICAL SYSTEMS, BOTH EXISTING AND NEW, AND PARTS | | | THEREOF SHALL BE MAINTAINED IN PROPER OPERATING | | | CONDITION IN ACCORDANCE WITH THE ORIGINAL DESIGN AND IN | | | A SAFE AND SANITARY CONDITION. DEVICES OR SAFEGUARDS | | | THAT ARE REQUIRED BY THIS CODE SHALL BE MAINTAINED IN | | | COMPLIANCE WITH THE CODE EDITION UNDER WHICH INSTALLED. | | | THE OWNER OR THE OWNER?S DESIGNATED AGENT SHALL BE | | | RESPONSIBLE FOR MAINTENANCE OF THE MECHANICAL SYSTEMS. | | | TO DETERMINE COMPLIANCE WITH THIS PROVISION, THE | | | BUILDING OFFICIAL SHALL HAVE THE AUTHORITY TO REQUIRE A | | | MECHANICAL SYSTEM TO BE REINSPECTED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-01-14 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-01-14 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2019-01-08 12:12:00 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PLUMBING PERMIT REQUIRED | | | | | | 1. PROVIDE PLUMBING RISER DIAGRAHM. | | | PLUMBING RISER - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1 ADMINISTRATION SECTION | | | 107.3.5.3 (12). | | | | | | P2601.2 CONNECTIONS TO DRAINAGE SYSTEM | | | PLUMBING FIXTURES, DRAINS, APPURTENANCES AND APPLIANCES | | | USED TO RECEIVE OR DISCHARGE LIQUID WASTES OR SEWAGE | | | SHALL BE DIRECTLY CONNECTED TO THE SANITARY DRAINAGE | | | SYSTEM OF THE BUILDING OR PREMISES, IN ACCORDANCE WITH | | | THE REQUIREMENTS OF THIS CODE. THIS SECTION SHALL NOT | | | BE CONSTRUED TO PREVENT INDIRECT WASTE CONNECTIONS | | | WHERE REQUIRED BY THE CODE. | | | | | | P2603.1 GENERAL. | | | IN THE PROCESS OF INSTALLING OR REPAIRING ANY PART OF A | | | PLUMBING AND DRAINAGE INSTALLATION, THE FINISHED | | | FLOORS, WALLS, CEILINGS, TILE WORK OR ANY OTHER PART OF | | | THE BUILDING OR PREMISES THAT MUST BE CHANGED OR | | | REPLACED SHALL BE LEFT IN A SAFE STRUCTURAL CONDITION | | | IN ACCORDANCE WITH THE REQUIREMENTS OF THE BUILDING | | | PORTION OF THIS CODE. | | | | | | 2. IF WATER HEATER IS TO BE REPLACED, INCLUDE IT ON THE | | | ENERGY CALCULATIONS REQUIRED UNDER THE ELECTRICAL | | | REVIEW. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | |
|
|
|