Plan Review Details - Permit 18120846
Plan Review Stops For Permit 18120846
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-02-13 Cont ID  
Sent By jpearson Date 2019-02-13 Time 13:35 Rev Time 0.00
Received By jpearson Date 2019-02-13 Time 13:35 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-12-28 Cont ID  
Sent By jpearson Date 2018-12-28 Time 15:19 Rev Time 0.00
Received By jpearson Date 2018-12-28 Time 15:19 Sent To I
Notes
2018-12-28 15:19:34CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. BATHROOM RECEPTACLE CIRCUITS D-30, D2-17 AND D2-22
 ARE SHOWN AS 15 AMP. A MINIMUM OF ONE 20 AMPERE BRANCH
 CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE
 OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS.
 PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4
 2. THERE IS A CONFLICT BETWEEN THE RISER DIAGRAM AND
 THE PANEL SCHEDULES. RISER SHOWS ONE PANEL WITH TWO
 SECTIONS. PANEL SCHEDULES SHOW TWO DIFFERENT PANELS,
 FIRST ONE WITH A 250 AMP MAIN BREAKER AND SECOND ONE
 WITH A 250 AMP MAIN BREAKER. IS PANEL D2 FEED FROM
 PANEL D? CLARIFY AND CORRECT. IF TWO PANELS, SHOW
 FEEDER SIZE TO EACH AND WHERE FEED FROM. WPB FBC
 107.2.1
 3. RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS SHALL
 HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8(A)(9); FBC RE E3902.9
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-02-13 Cont ID  
Sent By jpearson Date 2019-02-13 Time 13:36 Rev Time 0.00
Received By jpearson Date 2019-02-11 Time 10:23 Sent To  
Notes
2019-02-12 10:23:38RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2018-12-28 Time   Rev Time 0.00
Received By lmarchan Date 2018-12-21 Time 16:28 Sent To  
Notes
2018-12-26 16:28:24REVISION ROUTED TO JPEARSON


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved