| Plan Review Stops For Permit 18120823 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-04-29 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-04-29 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2019-04-29 12:15:22 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- DRAINAGE PLAN WAS DISCUSSED WITH RANDY WERTEPNY | | | (ENGINEER). PROVIDE REVISED DRAINAGE PLAN PRIOR TO | | | INSPECTIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-28 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-28 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2019-03-28 13:55:08 | NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | | ISSUANCE. | | | | | | | | | | | | ORIGINAL COMMENT: | | | 1- REVISE DRAINAGE PLAN SHOWN ON SHEET C-1. BASED ON | | | THE GRADE ELEVATIONS ON THE REAR OF THE LOT, IT LOOKS | | | LIKE THE WATER IS BEING DIVERTED TO THE NEIGHBOR. | | | REVISE AS REQUIRED SO WATER IS KEPT WITHIN THE LOT OR | | | DIVERTED TO AN APPROVED COLLECTION POINT. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | RESPONSE: | | | REPEAT COMMENT (TWO TIMES). NO ADDRESSED AT ALL. | | | REVISED DRAINAGE PLAN SHOWS SECTION C-C WHICH SHOWS A | | | BERM WITH ONE OF THE SLOPES TOWARDS THE REAR PROPERTY. | | | THEREFORE, DIVERTING THE WATER TOWARD THE REAR REAR | | | PROPERTY. REVISE AS REQUIRED. | | | | | | 2- OK | | | | | | 3- OK. | | | | | | 4- OK | | | | | | 5- ENERGY CALCULATIONS: | | | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER'S NAME. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT (TWO TIMES). NO ADDRESSED AT ALL. | | | PARTIALLY COMPLIED. PROVIDE CORRECT NAME OF CONTRACTOR. | | | | | | ORIGINAL COMMENT: | | | B)ITEM #5 ON PAGE 1 OF 5 STATES THAT THIS IS NOT A | | | WORST CASE SCENARIO BUT ON PAGE 2 OF 5 IT SHOWS THAT | | | THE HOUSE WAS ROTATED 315 DEGREES. THIS IS | | | CONTRADICTORY. THE ENERGY CALCULATIONS NEED TO BE DONE | | | FOR THE ACTUAL ORIENTATION OF THE BUILDING. REVISE AS | | | REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT (THREE TIMES). NO ADDRESSED AT ALL. | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | C)PROVIDE WINDOWS AND DOORS DOCUMENTATION FROM | | | MANUFACTURER SHOWING THE SHGC FACTOR AND U-FACTOR | | | EFFICIENCIES SHOWN ON ITEM #7 ON PAGE 1 OF 5. SEC. | | | R405.4.3 FBC-ENERGY CONSERVATION. NOTE: THIS IS ONLY | | | REQUIRED WHEN PERSON DOING THE CALCULATIONS IS NOT | | | USING THE PROGRAM DEFAULT FACTORS. | | | | | | RESPONSE: | | | REPEAT COMMENT (THREE TIMES). NO ADDRESSED AT ALL. | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | D) CEILING R-VALUE INSULATION ON ITEM #10 DOESN'T MATCH | | | PLANS. REVISE AS REQUITED TO MATCH. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT (THREE TIMES). NO ADDRESSED AT ALL. | | | REPEAT COMMENT. NOT ADDRESSED. ALSO, THE ATTIC IS NOT | | | VENTED. PLANS SPECIFY FOAM INSULATION. SEE PLANS AND | | | REVISE AS REQUIRED. | | | | | | ORIGINAL COMMENT: | | | E) PROVIDE THE NAME OF PERSON PERFORMING THE ANALYSIS | | | AND GENERATING THE REPORT AS REQUIRED BY SEC. | | | R405.4.2.1 FBC- ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT (THREE TIMES). NO ADDRESSED AT ALL. | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | | | | F) PARTIALLY DONE. THE VENT RATIO WAS REVISED, BUT I | | | APOLOGIZE BECAUSE THIS ITEM WAS OVERLOOKED. THERE IS NO | | | VENTED ATTIC. SEE ITEM #5D ABOVE. | | | | | | RESPONSE: | | | REPEAT COMMENT (TWO TIMES). NO ADDRESSED AT ALL. | | | | | | ORIGINAL COMMENT: | | | G) REVISE WINDOWS ORIENTATION AND AREA ON PAGE 3 OF 5 | | | TO MATCH ACTUAL ORIENTATION AND AREA SHOWN ON PLANS. | | | NOTE: COORDINATE WITH ITEM #5(B) ABOVE. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT (THREE TIMES). NO ADDRESSED AT ALL. | | | REPEAT COMMENT. COORDINATE WITH ITEM #5(B) ABOVE. | | | | | | | | | NOTE: | | | LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND | | | SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS | | | ARE NOT USING THE DEFAULT FACTOR. | | | | | | 6- OK. | | | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL). | | | | | | A) PRECAST LINTELS. NOTE: NOA 16-0126.03 SPECIFIED ON | | | SHEET 3 OF 7 IS EXPIRED. REVISE AS REQUIRED ALSO. THERE | | | IS NO NEED TO SPECIFY NOA ON DRAWINGS. JUST REVIEW IN | | | WRITING THE ACTUAL PRODUCT APPROVAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. NO SUBMITTED AND NO WORD FROM | | | CONTRACTOR IF DEFERRED SUBMITTAL IS PREFERRED AT HIS | | | TIME. | | | | | | B) WINDOW MULLIONS AS SHOWN ON PLANS. ONLY ONE COPY WAS | | | SUBMITTED AND WAS VOID. NEED TWO COPIES. ALSO REQUIRED: | | | CLEARLY SPECIFY MULLION SIZE TO BE USED TO VERIFY | | | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. | | | | | | RESPONSE: | | | REPEAT COMMENT. NO ADDRESSED. AND NO WORD FROM | | | CONTRACTOR IF DEFERRED SUBMITTAL IS PREFERRED AT HIS | | | TIME. | | | | | | C)GARAGE DOOR FLORIDA PRODUCT APPROVAL SUBMITTED. DOOR | | | DOESN'T MEET THE POSITIVE DESIGN PRESSURES CALCULATED | | | BY THE ENGINEER OF RECORD. PROVIDE DOOR THAT MEETS THE | | | CALCULATED DESIGN PRESSURES. | | | | | | RESPONSE: | | | REPEAT COMMENT. NO SUBMITTED AND NO WORD FROM | | | CONTRACTOR IF DEFERRED SUBMITTAL IS PREFERRED AT HIS | | | TIME. | | | | | | | | | NOTE- | | | DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 8- OK. | | | | | | 9- OK. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-11 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-11 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2019-03-11 16:04:21 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | | ISSUANCE. | | | | | | | | | | | | ORIGINAL COMMENT: | | | 1- REVISE DRAINAGE PLAN SHOWN ON SHEET C-1. BASED ON | | | THE GRADE ELEVATIONS ON THE REAR OF THE LOT, IT LOOKS | | | LIKE THE WATER IS BEING DIVERTED TO THE NEIGHBOR. | | | REVISE AS REQUIRED SO WATER IS KEPT WITHIN THE LOT OR | | | DIVERTED TO AN APPROVED COLLECTION POINT. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | RESPONSE: | | | REVISED DRAINAGE PLAN SHOWS SECTION C-C WHICH SHOWS A | | | BERM WITH ONE OF THE SLOPES TOWARDS THE REAR PROPERTY. | | | THEREFORE, DIVERTING THE WATER TOWARD THE REAR REAR | | | PROPERTY. REVISE AS REQUIRED. | | | | | | 2- OK | | | | | | 3- SHEET D1: REVISE DESIGN CRITERIA SHOWN ON THE TOP | | | MIDDLE OF THE SHEET: | | | A) OK | | | | | | B)OK. | | | | | | 4- OK | | | | | | 5- ENERGY CALCULATIONS: | | | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER'S NAME. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | | | | RESPONSE: | | | PARTIALLY COMPLIED. PROVIDE CORRECT NAME OF CONTRACTOR. | | | | | | ORIGINAL COMMENT: | | | B)ITEM #5 ON PAGE 1 OF 5 STATES THAT THIS IS NOT A | | | WORST CASE SCENARIO BUT ON PAGE 2 OF 5 IT SHOWS THAT | | | THE HOUSE WAS ROTATED 315 DEGREES. THIS IS | | | CONTRADICTORY. THE ENERGY CALCULATIONS NEED TO BE DONE | | | FOR THE ACTUAL ORIENTATION OF THE BUILDING. REVISE AS | | | REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | C)PROVIDE WINDOWS AND DOORS DOCUMENTATION FROM | | | MANUFACTURER SHOWING THE SHGC FACTOR AND U-FACTOR | | | EFFICIENCIES SHOWN ON ITEM #7 ON PAGE 1 OF 5. SEC. | | | R405.4.3 FBC-ENERGY CONSERVATION. NOTE: THIS IS ONLY | | | REQUIRED WHEN PERSON DOING THE CALCULATIONS IS NOT | | | USING THE PROGRAM DEFAULT FACTORS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | D) CEILING R-VALUE INSULATION ON ITEM #10 DOESN'T MATCH | | | PLANS. REVISE AS REQUITED TO MATCH. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. ALSO, THE ATTIC IS NOT | | | VENTED. PLANS SPECIFY FOAM INSULATION. SEE PLANS AND | | | REVISE AS REQUIRED. | | | | | | ORIGINAL COMMENT: | | | E) PROVIDE THE NAME OF PERSON PERFORMING THE ANALYSIS | | | AND GENERATING THE REPORT AS REQUIRED BY SEC. | | | R405.4.2.1 FBC- ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | | | | F) PARTIALLY DONE. THE VENT RATIO WAS REVISED, BUT I | | | APOLOGIZE BECAUSE THIS ITEM WAS OVERLOOKED. THERE IS NO | | | VENTED ATTIC. SEE ITEM #5D ABOVE. | | | | | | ORIGINAL COMMENT: | | | G) REVISE WINDOWS ORIENTATION AND AREA ON PAGE 3 OF 5 | | | TO MATCH ACTUAL ORIENTATION AND AREA SHOWN ON PLANS. | | | NOTE: COORDINATE WITH ITEM #5(B) ABOVE. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. COORDINATE WITH ITEM #5(B) ABOVE. | | | | | | | | | NOTE: | | | LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND | | | SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS | | | ARE NOT USING THE DEFAULT FACTOR. | | | | | | 6- OK. | | | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL) | | | | | | A) PRECAST LINTELS. NOTE: NOA 16-0126.03 SPECIFIED ON | | | SHEET 3 OF 7 IS EXPIRED. REVISE AS REQUIRED ALSO. THERE | | | IS NO NEED TO SPECIFY NOA ON DRAWINGS. JUST REVIEW IN | | | WRITING THE ACTUAL PRODUCT APPROVAL. | | | | | | B) WINDOW MULLIONS AS SHOWN ON PLANS. ONLY ONE COPY WAS | | | SUBMITTED AND WAS VOID. NEED TWO COPIES. ALSO REQUIRED: | | | CLEARLY SPECIFY MULLION SIZE TO BE USED TO VERIFY | | | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. | | | | | | C)GARAGE DOOR FLORIDA PRODUCT APPROVAL SUBMITTED. DOOR | | | DOESN'T MEET THE DESIGN PRESSURES CALCULATED BY THE | | | ENGINEER OF RECORD. PROVIDE DOOR THAT MEETS THE | | | CALCULATED DESIGN PRESSURES. | | | | | | NOTE- | | | DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 8- OK. | | | | | | 9- OK. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-01-25 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-01-24 |
Time |
17:58 |
Sent To |
|
|
| Notes |
| 2019-01-25 17:05:59 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- REVISE DRAINAGE PLAN SHOWN ON SHEET C-1. BASED ON | | | THE GRADE ELEVATIONS ON THE REAR OF THE LOT, IT LOOKS | | | LIKE THE WATER IS BEING DIVERTED TO THE NEIGHBOR. | | | REVISE AS REQUIRED SO WATER IS KEPT WITHIN THE LOT OR | | | DIVERTED TO AN APPROVED COLLECTION POINT. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | 2- SHEET 1 OF 7: ENGINEER TO REVISE THE DESIGN | | | PRESSURES SHOWN ON THE EXTERIOR ELEVATIONS. DESIGN | | | PRESSURES SHOWN DON'T CORRESPOND TO EXPOSURE "D". ALSO, | | | CLARIFY WHAT ARE THE "OPENING DESIGN PRESSURE, PSF" | | | SHOWN ON THE UPPER RIGHT SIDE OF DRAWING FOR. THEY | | | DON'T MATCH DESIGN PRESSURES SHOWN ON EXTERIOR | | | ELEVATIONS EITHER. | | | | | | 3- SHEET D1: REVISE DESIGN CRITERIA SHOWN ON THE TOP | | | MIDDLE OF THE SHEET: | | | A) THE EXPOSURE CATEGORY IS "D" NOT "C". NOTE: | | | COORDINATE WITH ITEM #2 ABOVE. SEC. R301.2.1.4 | | | FBC-RESIDENTIAL. | | | | | | B)REVISE AND CLEARLY SPECIFY ALL THE LIVE AND DEAD | | | LOADS ON THE ROOF TRUSSES. CLEARLY SPECIFY THE TOP AND | | | BOTTOM CHORDS LIVE AND DEAD LOADS. NOTE: REVISE THE | | | ATTIC LIVE LOAD (BOTTOM OF TRUSS CHORD). ACCORDING TO | | | NOTES "B" AND "G" OF TABLE R301.5 FBC-RESIDENTIAL THE | | | MIN. LIVE LOAD IS 20 POUNDS. | | | | | | 4- FLOOR PLAN ON SHEET 2 OF 7 DOESN'T PROVIDE ANY | | | SPECIFICATIONS FOR THE INSULATION IN THE WALLS BETWEEN | | | THE GARAGE AND THE REST OF THE HOUSE. PROVIDE | | | SPECIFICATIONS. NOTE: COORDINATE WITH THE ENERGY | | | CALCULATIONS TO AVOID CONFLICT/DELAYS. SEC. R103.2 | | | FBC-ENERGY CONSERVATION. | | | | | | 5- ENERGY CALCULATIONS: | | | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER'S NAME. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | | | | B)ITEM #5 ON PAGE 1 OF 5 STATES THAT THIS IS NOT A | | | WORST CASE SCENARIO BUT ON PAGE 2 OF 5 IT SHOWS THAT | | | THE HOUSE WAS ROTATED 315 DEGREES. THIS IS | | | CONTRADICTORY. THE ENERGY CALCULATIONS NEED TO BE DONE | | | FOR THE ACTUAL ORIENTATION OF THE BUILDING. REVISE AS | | | REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | C)PROVIDE WINDOWS AND DOORS DOCUMENTATION FROM | | | MANUFACTURER SHOWING THE SHGC FACTOR AND U-FACTOR | | | EFFICIENCIES SHOWN ON ITEM #7 ON PAGE 1 OF 5. SEC. | | | R405.4.3 FBC-ENERGY CONSERVATION. NOTE: THIS IS ONLY | | | REQUIRED WHEN PERSON DOING THE CALCULATIONS IS NOT | | | USING THE PROGRAM DEFAULT FACTORS. | | | | | | D) CEILING R-VALUE INSULATION ON ITEM #10 DOESN'T MATCH | | | PLANS. REVISE AS REQUITED TO MATCH. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION. | | | | | | E) PROVIDE THE NAME OF PERSON PERFORMING THE ANALYSIS | | | AND GENERATING THE REPORT AS REQUIRED BY SEC. | | | R405.4.2.1 FBC- ENERGY CONSERVATION. | | | | | | F) REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 5. THE | | | RATIO IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL. | | | OR, PROVIDE COMPLETE DOCUMENTATION SHOWING COMPLIANCE | | | WITH THE 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON | | | SEC. R806.2 AND COORDINATE WITH ENGINEER OF RECORD SO | | | PLANS ARE REVISED ACCORDINGLY. | | | | | | G) REVISE WINDOWS ORIENTATION AND AREA ON PAGE 3 OF 5 | | | TO MATCH ACTUAL ORIENTATION AND AREA SHOWN ON PLANS. | | | NOTE: COORDINATE WITH ITEM #5(B) ABOVE. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | NOTE: | | | LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND | | | SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS | | | ARE NOT USING THE DEFAULT FACTOR. | | | | | | 6- ALL PRODUCT APPROVALS SUBMITTED WILL BE REVIEWED | | | ONCE THE DESIGN PRESSURES ARE REVISED/CLARIFIED. SEC. | | | R301.1 FBC-RESIDENTIAL. | | | | | | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL) | | | | | | A) PRECAST LINTELS. NOTE: NOA 16-0126.03 SPECIFIED ON | | | SHEET 3 OF 7 IS EXPIRED. REVISE AS REQUIRED ALSO. THERE | | | IS NO NEED TO SPECIFY NOA ON DRAWINGS. JUST REVIEW IN | | | WRITING THE ACTUAL PRODUCT APPROVAL. | | | | | | 8-VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. VALUATION WAS UPDATED TO $264,094. THE | | | PERMIT FEE BALANCE IS $4617.18. | | | | | | 9- FOUNDATION PLAN (SHEET 4 OF 7) IS MISSING THE | | | ENGINEER'S OF RECORD SEAL. CHAPTER 471 F.S. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-03-15 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-03-15 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-01-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-07 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-07 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2019-01-07 16:37:21 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3606.3 | | | 3. PROVIDE AIC RATING OF SERVICE PANEL. NEC 110.3, | | | 110.9; FBC RE E3606.3 | | | 4. BLOCK NOTE STATES THAT THERE IS NO LOW VOLTAGE | | | WIRING IN BUILDING, BUT THE LAUNDRY ROOM SHOWS A MEDIA | | | BOX, AND ANOTHER NOTE STATES THERE IS CAT 5E WIRING FOR | | | PHONES. PROVIDE CLARIFICATION AND/OR CORRECTION. WPB | | | FBC 107.2.1 | | | 5. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC RE R315.1 | | | 6. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE INCLUDING THE GARAGE DOOR OPENER. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 7. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 8. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | | R314.3(4), NFPA 72:29.8.3.4 | | | 9. EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND | | | SEALED(IF APPLICABLE) BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. PROVIDE CORRECTION. WPB FBC 107.1; FS 471/481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
rsklarew |
Date |
2019-05-02 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
rsklarew |
Date |
2019-05-02 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-04-29 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-04-25 |
Time |
15:57 |
Sent To |
I |
|
| Notes |
| 2019-04-26 15:57:21 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-28 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-18 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2019-03-19 14:39:22 | RESUB ROUTED TO HMOSER'S OFFICE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-03-15 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-03-15 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-01-25 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-12-21 |
Time |
15:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-01 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-01 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2019-05-01 16:18:03 | MU-2019-013341-0000 | | | TOTAL PAID $9,766.49 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-28 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-28 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2019-03-28 13:59:59 | IMPACT FEES - PAPER SUBMITTALS | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-11 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-11 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2019-03-11 16:05:31 | IMPACT FEES - PAPER SUBMITTALS | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-01-25 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-01-25 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2019-01-25 17:07:30 | IMPACT FEES - PAPER SUBMITTALS | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-04-29 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-04-29 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2019-04-29 14:08:54 | REVISED LOAD CALCULATIONS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-03-25 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-03-25 |
Time |
10:07 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-03-15 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-03-15 |
Time |
14:20 |
Sent To |
I |
|
| Notes |
| 2019-03-15 14:20:58 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED RETURN AIR IN MASTER BEDROOM PER 2017 FLORIDA | | | BUILDING CODE - RESIDENTIAL M1602.3 BALANCED RETURN | | | AIR. | | | | | | 2- CANNOT TAKE RETURN AIR FROM CLOSET PER 2017 FLORIDA | | | BUILDING CODE - RESIDENTIAL M1602.2 RETURN AIR | | | OPENINGS. | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-01-04 |
Time |
09:22 |
Rev Time |
|
| Received By |
cmontell |
Date |
2019-01-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-01-04 09:22:21 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED RETURN AIR IN MASTER BEDROOM PER 2017 FLORIDA | | | BUILDING CODE - RESIDENTIAL M1602.3 BALANCED RETURN | | | AIR. | | | | | | 2- CANNOT TAKE RETURN AIR FROM CLOSET PER 2017 FLORIDA | | | BUILDING CODE - RESIDENTIAL M1602.2 RETURN AIR | | | OPENINGS. | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-12 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-12 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-12 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2019-03-12 14:49:47 | PLUMBING PROVISO: (1)HAMMER ARRESTORS REQUIRED AT QUICK | | | CLOSING | | | VALVES FBC-R P2903.5.(2) BATH TUBS/ ROMAN TUBS SHALL BE | | | TEMPERED | | | BY A 1070 DEVICE TO 120F FBC-R P2713.3. (3) HOT WATER | | | PIPING SHALL COMPLY | | | WITH FBC-EFFICIENCY R403.5.3 AND BE INSULATED TO R-3 | | | VALUE. (4) SEWER CLEAN | | | OUT SHALL BE 3"/ SAME SIZE AS THE PIPING IT SERVES. | | | FBC-R P3005.2.5 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-15 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-15 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2019-01-15 16:08:28 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: | | | PLUMBING COMMENTS: DENIED | | | | | | 1. RE: PLAN SHEET 5 OF 7; PLUMBING RISER DIAGRAM | | | A. PER FBC RES P3108.1, "EACH WET VENTED FIXTURE DRAIN | | | SHALL CONNECT DIRECTLY TO THE HORIZONTAL WET VENT." IN | | | THE CASE OF THE MASTER BATH, THE TUB DRAIN AND WATER | | | CLOSET DRAIN SHALL NOT CONNECT TO EACHG OTHER BEFORE | | | CONNECTING TO THE VENT. | | | B. PER FBC RES P3104.4 AND 3104.5 THE DRY VENT SHALL | | | RISE VERTICALLY ABOVE THE FLOOD LEVEL RIM OF HIGHEST | | | TRAPPED FIXTURE BEING VENTED BEFORE OFFSETTING AND | | | CONNECTING TO ANOTHER VENT. THE LAVATORY IN THE IN BATH | | | #2 DOES NOT COMPLY. | | | C. PER WPB FBC 107.2.1, INCLUDE THE WASTE AND VENT | | | PIPING FOR THE HALF BATH ON THE PLUMBING RISER DIAGRAM. | | | D. PER FBC P2717.2 SINK AND DISHWASHER, THE COMBINED | | | DISCHARGE FROM A DISHWASHER AND A ONE- OR | | | TWO-COMPARTMENT SINK, WITH OR WITHOUT A FOOD-WASTE | | | DISPOSER, SHALL BE SERVED BY A TRAP OF NOT LESS THAN | | | 11/2 INCHES (38 MM) IN OUTSIDE DIAMETER. THE DISHWASHER | | | DISCHARGE PIPE OR TUBING SHALL RISE TO THE UNDERSIDE OF | | | THE COUNTER AND BE FASTENED OR OTHERWISE HELD IN THAT | | | POSITION BEFORE CONNECTING TO THE HEAD OF THE | | | FOOD-WASTE DISPOSER OR TO A WYE FITTING IN THE SINK | | | TAILPIECE | | | 2. PER WPB FBC 107.2.1, ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-03-11 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-11 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2019-03-11 16:07:27 | SHINGLES CERTAIN TEED NOA 16-1109.18 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-01-25 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-01-25 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2019-01-25 17:06:51 | ALL PRODUCT APPROVALS SUBMITTED WILL BE REVIEWED ONCE | | | THE DESIGN PRESSURES ARE REVISED/CLARIFIED. SEC. R301.1 | | | FBC-RESIDENTIAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-03-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-03-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-03-05 15:48:50 | - SEPERATE PERMIT REQUIRED FOR DRIVEWAY/WALKWAY AND | | | LANDSCAPING PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | | OCCUPANCY (C.O.). | | | | | | - CONDITIONAL APPROVAL FOR LANDSCAPING ATTACHED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-09 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-01-09 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-01-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-01-09 08:40:18 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SHOW SETBACK DISTANCE OF THE A/C UNIT COMPRESSOR IN | | | THE SITE PLAN. PLEASE NOTE THAT ANY MECHANICAL | | | EQUIPMENT CANNOT PROJECT MORE THAN 4 FT. INTO A | | | SETBACK. [ZLDR S.94-305(B)(4)] | | | | | | 2.) HOW HIGH IS THE STOOP ON THE SIDE OF THE PROPERTY? | | | A STOOP LESS THAN 3 FT. ABOVE GRADE MAY ENCROACH INTO A | | | SETBACK TO A POINT NO CLOSER THAN 2 FT. TO THE PROPERTY | | | LINE. STOOPS GREATER THAN 3 FT. ABOVE GRADE SHALL | | | COMPLY WITH THE SETBACK REQUIREMENTS FOR THE PRIMARY | | | STRUCTURE. PLEASE DEMONSTRATE COMPLIANCE BY SHOWING | | | ADDITIONAL DRAWINGS AND SETBACK DISTANCE FROM THE | | | PROPERTY LINE(S). [ZLDR S.94-305(B)(7)] | | | | | | 3.) SHOW DIMENSIONS FOR THE PROPOSED DRIVEWAY IN THE | | | SITE PLAN. THE DRIVEWAY CANNOT EXCEED 20 FT. IN WIDTH. | | | [ZLDR S.94-312(1)] | | | | | | 4.) THE REQUIRED FRONT YARD (AREA WITHIN THE FIRST 25 | | | FT. OF SOUTH MANGONIA CIRCLE) SHALL HAVE A MINIMUM OF | | | 1,000 SQ. FT. OF LANDSCAPED AREA. PLEASE PROVIDE THE | | | CALCULATIONS FOR THE FRONT YARD TO DEMONSTRATE | | | COMPLIANCE. [ZLDR S.94-482] | | | | | | 5.) THE CONDITIONAL APPROVAL FORM FOR LANDSCAPING AND | | | IRRIGATION MUST BE COMPLETED PRIOR TO ZONING SIGN-OFF. | | | [NOTE: THE CONDITIONAL APPROVAL FORM WAS SENT TO | | | MICHAEL DIACZUN OF RJM CUSTOM HOMES TO PROVIDE TO THE | | | OWNER OF THE PROPERTY ON 1/9/19 VIA EMAIL.] | | | | | | | | | NOTES: | | | | | | * SEPARATE PERMIT REQUIRED FOR DRIVEWAY AND WALKWAYS, | | | LANDSCAPING | | | | | | * A TREE ALTERATION PERMIT WILL BE REQUIRED PRIOR TO | | | THE REMOVAL OF ANY TREES/PALMS ON THE PROPERTY. PLEASE | | | CONTACT THE CITY'S LANDSCAPE PLANNER, RAY CARANCI, AT | | | (561) 822-1462. | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|