| Plan Review Stops For Permit 18120801 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-15 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-15 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-12 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-12 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2019-02-12 16:55:54 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING APPROVED WITH PROVISO: | | | | | | PRIOR TO INSPECTION PLEASE PROVIDE: | | | | | | 1. WELD PROCEDURE SPECIFICATIONS AND WELDERS | | | CERTIFICATIONS. | | | | | | 2. STEEL SHOP DRAWINGS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-02-11 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-11 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-11 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2019-02-11 17:22:34 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | | | | | | | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | | | 1. MISSING INFORMATION FOR THE TUBE STEEL BEAM | | | CONNECTIONS AT ROOF EXPANSION JOINTS FOUND ON PAGES | | | (CEA 161) AND (CES 101). (COMPLIED) | | | | | | 2. WE NEED TO REVIEW/AUDIT THE APPROVED STEEL SHOP | | | DRAWINGS. (NOT COMPLIED, PLEASE SUBMIT STEEL SHOP | | | DRAWINGS) | | | | | | 3. WE NEED AN APPROVED CLARIFICATION THAT THE WIND LOAD | | | DESIGN (RISK CATEGORY 2) AS INDICATED ON PAGE (CES | | | 001) | | | IS ACCURATE. IT APPEARS THAT THIS MAY ACTUALLY BE A | | | RISK CATEGORY 3. (COMPLIED) | | | | | | 4. WE NEED TO REVIEW/AUDIT THE STEEL ERECTORS WELD | | | PROCEDURE SPECIFICATIONS AS PER THE FBC B REFERENCED | | | STANDARDS AND THE REQUIREMENTS INDICATED ON PAGE (CES | | | 004) REFERENCING THE AMERICAN WELDING SOCIETY. (NOT | | | COMPLIED, PLEASE SUBMIT THE WELD PROCEDURE | | | SPECIFICATIONS) | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-01-28 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-01-28 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-01-28 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2019-01-28 15:16:49 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | | | 1. MISSING INFORMATION FOR THE TUBE STEEL BEAM | | | CONNECTIONS AT ROOF EXPANSION JOINTS FOUND ON PAGES | | | (CEA 161) AND (CES 101). | | | 2. WE NEED TO REVIEW/AUDIT THE APPROVED STEEL SHOP | | | DRAWINGS. | | | 3. WE NEED AN APPROVED CLARIFICATION THAT THE WIND LOAD | | | DESIGN (RISK CATEGORY 2) AS INDICATED ON PAGE (CES 001) | | | IS ACCURATE. IT APPEARS THAT THIS MAY ACTUALLY BE A | | | RISK CATEGORY 3. | | | 4. WE NEED TO REVIEW/AUDIT THE STEEL ERECTORS WELD | | | PROCEDURE SPECIFICATIONS AS PER THE FBC B REFERENCED | | | STANDARDS AND THE REQUIREMENTS INDICATED ON PAGE (CES | | | 004) REFERENCING THE AMERICAN WELDING SOCIETY. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-01-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-21 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-21 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2019-01-21 08:25:06 | PRIVATE PROVIDER REVIEW CONFIRMED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-01-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-01-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-01-07 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2019-01-09 15:56:21 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) FIRE SPRINKLERS ARE INDICATED AND SHOP DRAWINGS ARE | | | REQUIRED UNDER SEPARATE PERMIT. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-03-08 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-22 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-02-21 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-14 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-02-13 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-07 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-28 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-01-28 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-01-04 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-01-22 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-01-22 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-02-15 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-02-15 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-01-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-21 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-21 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-03-07 |
Time |
16:28 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-03-07 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
| 2019-03-07 16:29:03 | THE CANOPY LAYOUT DOES NOT MATCH THE CANOPY APPROVED BY | | | THE CITY COMMISSION. THE COLUMNS ARE NOT IN THE SAME | | | LOCATIONS; THEREFORE, THE CANOPY IS LARGER. A MINOR | | | AMENDMENT SHOWING THE FINAL CONDITIONS IS REQUIRED | | | PRIOR TO C.O. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-02-21 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-02-21 |
Time |
15:23 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-02-21 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2019-02-21 15:27:33 | FAILED | | | | | | 1) REPEAT COMMENT: THE TYPICAL CANOPY COLUMN - | | | ELEVATION, DETAIL 7 ON SHEET CEA 160 DOES NOT MATCH THE | | | COLUMNS SHOWN ON CEA 150. DETAIL 7 FROM SHEET CEA160 | | | SHOWS THE NARROW BANDS AND THE BASE AS RUBY GRANITE AND | | | THE WIDER BANDS AS JERUSALEM STONE. SHEET CEA150 SHOWS | | | THE NARROW BANDS AS AE35, JERUSALEM STONE ON THE | | | LEGEND, AND THE WIDER BANDS AS AE36, RUBY GRANITE ON | | | THE LEGEND. ALL FOUR OF THE CANOPY ELEVATION DRAWINGS | | | SHOW THIS SAME LABELING OF THE NARROW AND WIDE BANDS | | | AND NONE OF THE ELEVATION DRAWINGS CALL OUT THE BASE | | | MATERIAL. ALL PLANS MUST SHOW THE SAME CONDITIONS. | | | | | | | | | CONDITION: THE CANOPY LAYOUT DOES NOT MATCH THE CANOPY | | | APPROVED BY THE CITY COMMISSION. THE COLUMNS ARE NOT IN | | | THE SAME LOCATIONS; THEREFORE, THE CANOPY IS LARGER. A | | | MINOR AMENDMENT SHOWING THE FINAL CONDITIONS IS | | | REQUIRED PRIOR TO C.O. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-02-12 |
Time |
16:57 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-02-12 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2019-02-12 17:12:59 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES. | | | | | | 1) REPEAT COMMENT: THE TYPICAL CANOPY COLUMN - | | | ELEVATION, DETAIL 7 ON SHEET CEA 160 DOES NOT MATCH THE | | | COLUMNS SHOWN ON CEA 150. ***** ALL PLANS MUST SHOW THE | | | SAME CONDITIONS, SO IF DETAIL DETAIL 7 ON SHEET CEA 160 | | | IS THE CORRECT INSTALLATION, THEN THE COLUMNS, WITH THE | | | CORRESPONDING LABELS, ON SHEET CEA 150 NEED TO BE | | | CORRECTED SO THAT ALL PLANS SHOW THE SAME CONDITIONS. | | | ***** | | | | | | CONDITION: THE CANOPY LAYOUT DOES NOT MATCH THE CANOPY | | | APPROVED BY THE CITY COMMISSION. THE COLUMNS ARE NOT IN | | | THE SAME LOCATIONS; THEREFORE, THE CANOPY IS LARGER. A | | | MINOR AMENDMENT SHOWING THE FINAL CONDITIONS IS | | | REQUIRED PRIOR TO C.O. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-01-24 |
Time |
14:25 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2019-01-24 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2019-01-24 14:25:18 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES. | | | | | | 1) THE CANOPY LAYOUT DOES NOT MATCH THE CANOPY APPROVED | | | BY THE CITY COMMISSION. THE COLUMNS ARE NOT IN THE SAME | | | LOCATIONS; THEREFORE, THE CANOPY IS LARGER. A MINOR | | | AMENDMENT SHOWING THE FINAL CONDITIONS IS REQUIRED | | | PRIOR TO C.O. | | | | | | 2) PROVIDE THE SITE PLAN THAT SHOWS THE ACCURATE | | | SETBACK FROM SAPODILLA AVENUE. PLEASE ENSURE THAT THE | | | CHANGED SIZE, REVERENCED IN COMMENT NO. 1, ABOVE, HAVE | | | BEEN FACTORED IN ON THE SITE PLAN WITH THE SETBACKS. | | | | | | 3) THE TYPICAL CANOPY COLUMN - ELEVATION, DETAIL 7 ON | | | SHEET CEA 160 DOES NOT MATCH THE COLUMNS SHOWN ON CEA | | | 150. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] |
|
|