Plan Review Details - Permit 18120789
Plan Review Stops For Permit 18120789
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-02 Cont ID  
Sent By rmcdouga Date 2019-01-02 Time 15:01 Rev Time 0.00
Received By rmcdouga Date 2019-01-02 Time 15:01 Sent To I
Notes
2019-01-02 15:20:03PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 ROOFING PRODUCT APPROVAL FOR BALCONY NOA NO. 15-0707.04
 IS DENIED.
  
 1) THE LIQUID APPLIED MEMBRANE ROOFING SYSTEM ON SHEET
 14 OF NOA NO. 15-0707.04 IS FOR AN INSULATED WOOD DECK.
 THE PLANS DO NOT SPECIFY ANY INSULATION ON TOP OF THE
 PLYWOOD AT THE BALCONY. SUBMIT PRODUCT APPROVALS THAT
 CORRESPOND WITH THE PLANS OR REVISE THE PLANS. FBC
 107.2.1
  
 2) THE DESIGN PRESSURE FOR THE SYSTEM ON SHEET 14 IS
 -60 PSF AND LIMITATION NUMBER 7 WHICH DOES NOT ALLOW
 ANY INCREASE. SHEET S000 OF THE PLANS SPECIFIES THE
 REQUIRED DESIGN PRESSURES AS -116 PSF IN ROOF ZONE 3
 AND -79 PSF IN ROOF ZONE 2. SUBMIT PRODUCT APPROVALS
 WITH ADEQUATE DESIGN PRESSURES.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-12-31 Cont ID  
Sent By fmittner Date 2018-12-31 Time 12:08 Rev Time 0.00
Received By fmittner Date 2018-12-31 Time 12:08 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-02 Cont ID  
Sent By rmcdouga Date 2019-01-02 Time 15:20 Rev Time 0.00
Received By rmcdouga Date 2018-12-21 Time 16:24 Sent To  
Notes
2018-12-26 16:24:24ROUTED TO HISTORIC INBOX


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved