Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-05-02 Cont ID  
Sent By pvalenti Date 2019-05-02 Time 08:06 Rev Time 0.00
Received By pvalenti Date 2019-05-02 Time 08:05 Sent To  
Notes
2019-05-02 08:09:19PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 APPROVED WITH PROVISO:
  
 AT TIME OF INSPECTION, PROVIDE ALL DESIGNER OF RECORD
 REVIEWED/APPROVED (SIGNED/STAMPED) PRODUCT APPROVALS
 INCLUDING MANUFACTURER'S SPECIFICATIONS FOR ALUMINUM
 TRELLIS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-03-12 Cont ID  
Sent By pvalenti Date 2019-03-12 Time 13:53 Rev Time 0.00
Received By pvalenti Date 2019-03-12 Time 09:25 Sent To  
Notes
2019-03-12 14:21:06****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING 2ND PLAN REVIEW (DENIED):
  
 1. OK
 2. OK
 3. OK
 4. A. OK BY PROVISO (PROVIDE AT TIME OF INSPECTION). IT
 APPEARS THAT THE INTERIOR TRIM IS NON COMBUSTIBLE.
 PLEASE PROVIDE THE MANUFACTURER'S SPECIFICATIONS FOR
 THE ALUMINUM TRELLIS.
 B. OK (NO FABRIC)
 5. OK
 6. FBC B 107.2.1.2 (FAIL) SHEET A3-02 DOES NOT MATCH
 THE OTHER PAGES.
 7. A. OK THE PRODUCT APPROVALS FOR THE LOUVERS AND ROOF
 TOP VENTILATORS WERE SUBMITTED BUT NEED TO BE APPROVED
 BY DESIGNER OF RECORD PER NOTE (7B) BELOW
 B. OK BY PROVISO FL ADMIN. RULES FL 61G1-23.015 THE
 DESIGNER OF RECORD NEEDS TO REVIEW AND STAMP THE
 PRODUCT APPROVALS.
 C. OK BY PROVISO THE DESIGNER OF RECORD NEEDS TO REVIEW
 AND STAMP THE PRODUCT APPROVALS.
 8. FBC B 107 (FAIL) THIS ITEM HAS NOT BEEN ADDRESSED.
 9. OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-23 Cont ID  
Sent By jwitmer Date 2019-01-23 Time 13:25 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2019-01-23 13:25:532017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18120675
 ADD: 2500 S. DIXIE HWY. TENANT A MERCANTILE/ TENANT B
 BUSINESS
 CONT: DLP CONSTRUCTION INC.
 TEL: 770-887-3573
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JAN. 23/ 2019
 ACTION: DENIED
  
 1) SHEET 002-A0-10 THE LIFE SAFETY SHEET. PLEASE NOTE
 UNDER THE SCOPE OF WORK TENANT A MERCANTILE HAS 4265
 SQ. FT. THE SQUARE FOOTAGE TAKEN PER OCCUPANT IS 30 SQ.
 FT. PLEASE NOTE UNDER THE 2017 FBC-B TABLE 1004.1.2 FOR
 MERCANTILE WAS CHANGED IN THE 2017 CODE TO 60 SQ. FT.
 PER OCCUPANT. 4265/60 = 72 OCCUPANTS.
  
 2) SHEET 002-A0-10 THE LIFE SAFETY SHEET THE TOTAL
 OCCUPANT LOAD WILL ALSO CHANGE 72+10= 82 OCCUPANTS.
 2017 FBC-B TABLE 1004.1.2.
  
 3) SHEET 009-A1-02 SHOWS 2 ADA RESTROOMS 104 & 105.
 NEITHER RESTROOM PROVIDES THE WIDTH OF THE ROOM, PLEASE
 PROVIDE THE WIDTH OF BOTH RESTROOMS TO SHOW CODE
 COMPLIANCE WITH 604.3.1 OF THE 2017 FBC ACCESSIBILITY
 CODE.
  
 4A) SHEET 009-A1-02 SHOWS TRELLIS IN THE RETAIL AREA.
 THIS SHEET SHOWS A DETAIL 1/ A6.03. SHEET 015-A6.03
 SHOWS VARIOUS SECTIONS OF THE TRELLIS AND INDICATES
 THAT THE MANUFACTURER MODULO IS THE PREFERRED VENDOR.
 PLEASE PROVIDE ADDITIONAL INFORMATION ON THE PROPOSED
 TRELLIS WHAT TYPE OF MATERIAL WILL THE TRELLIS BE MADE
 OF? DOES THE SIDE WALLS OF THE TRELLIS SIT AGAINST THE
 WALLS? DOES THE CEILING IN THE TRELLIS SIT TIGHT
 AGAINST THE CEILING OR WILL IT BE SET OUT FROM THE
 CEILING? THIS REVIEW CYCLE WE ARE LOOKING AT CALLING
 THIS SYSTEM INTERIOR TRIM AND NEEDING TO SHOW
 COMPLIANCE WITH:
  
 2017 FBC-B SECTION 806.7 INTERIOR TRIM. MATERIAL, OTHER
 THAN FOAM PLASTIC USED AS INTERIOR TRIM, SHALL HAVE A
 MINIMUM CLASS C FLAME SPREAD AND SMOKE-DEVELOPED INDEX
 WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723, AS
 DESCRIBED IN SECTION 803.1.1. COMBUSTIBLE TRIM,
 EXCLUDING HANDRAILS AND GUARDRAILS, SHALL NOT EXCEED 10
 PERCENT OF THE SPECIFIC WALL OR CEILING AREA TO WHICH
 IT IS ATTACHED.
  
 4B) ON THE CEILING PANEL OF THE TRELLIS IF FABRIC IS TO
 BE WOVEN THROUGH THE VARIOUS HORIZONTAL SLATS THEN
 COMPLIANCE WITH SECTION 806.3 OF THE FBC-B. [F] 806.3
 COMBUSTIBLE DECORATIVE MATERIALS.
  
 IN OTHER THAN GROUP I-3, CURTAINS, DRAPERIES, FABRIC
 HANGINGS AND SIMILAR COMBUSTIBLE DECORATIVE MATERIALS
 SUSPENDED FROM WALLS OR CEILINGS SHALL COMPLY WITH
 SECTION 806.4 AND SHALL NOT EXCEED 10 PERCENT OF THE
 SPECIFIC WALL OR CEILING AREA TO WHICH SUCH MATERIALS
 ARE ATTACHED.
  
 5) THE FLOOR PLAN 009-A1-02 SHOWS A ALCOVE BETWEEN THE
 2 RESTROOMS 104 & 105. THIS AREA DOES NOT HAVE A ROOM
 IDENTIFICATION NUMBER. THE PLAN DOES SHOW A HIGH/ LOW
 DRINKING FOUNTAIN IN THE ALCOVE AND A SQUARE BOXED
 FIGURE. THERE IS A DETAIL, DETAIL 12/ A6.02 WHICH SHOWS
 THIS ITEM REFERRED TO AS T.9. PLEASE PROVIDE ADDITIONAL
 INFORMATION I COULD ONLY FIND A T-1 IN THE FINISH
 SCHEDULE FOR PORCELAIN TILE.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. THIS MAY
 INFRINGE ON ACCESSIBILITY TO THE DRINKING FOUNTAINS?
  
 6) PLEASE NOTE THE FLOOR PLAN FOUND ON SHEET 009-A1-02
 DOES NOT MATCH THE SECURITY FLOOR PLAN ON SHEET
 012-A3-02. 107.2.1.2 ADDITIONAL INFORMATION IS
 REQUIRED, DISCREPANCY IN PLANS.
  
 7A) THE MECHANICAL SHEET 021-M1 SHOWS NEW WALL TYPE
 LOUVERS AND GRAVITY VENTILATORS. PLEASE SHOW COMPLIANCE
 WITH:
 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31(C) WALL LOUVERS,
 (G) GREENHECK ROOF TOP VENTILATORS MODEL GRSR-12.
  
 7B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 7C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 8) FOR THE ROOF TOP VENTILATORS PLEASE PROVIDE THE WIND
 DESIGN CRITERIA IN ACCORDANCE WITH:
 2017 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 8.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 8.2. RISK CATEGORY.
  
 8.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1.
  
 8.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 8.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF.
 TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING.
 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
  
 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-04-25 Cont ID  
Sent By jpearson Date 2019-04-25 Time 12:49 Rev Time 0.00
Received By jpearson Date 2019-04-25 Time 12:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-01-11 Cont ID  
Sent By jleahy Date 2019-01-11 Time 15:37 Rev Time 0.00
Received By jleahy Date 2019-01-11 Time 15:37 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2019-01-11 Cont ID  
Sent By jleahy Date 2019-01-11 Time 15:37 Rev Time 0.00
Received By jleahy Date 2019-01-11 Time 15:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-04-01 Cont ID  
Sent By scaldero Date 2019-04-01 Time 13:44 Rev Time 0.00
Received By scaldero Date 2019-04-01 Time 13:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-02-12 Cont ID  
Sent By scaldero Date 2019-02-12 Time 13:14 Rev Time 0.00
Received By scaldero Date 2019-02-12 Time 13:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-12-20 Cont ID  
Sent By scaldero Date 2018-12-20 Time 09:39 Rev Time 0.00
Received By scaldero Date 2018-12-20 Time 09:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-05-02 Cont ID  
Sent By pvalenti Date 2019-05-02 Time 08:21 Rev Time 0.00
Received By pvalenti Date 2019-03-28 Time 10:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-14 Cont ID  
Sent By gjohnson Date 2019-03-14 Time 12:07 Rev Time 0.00
Received By gjohnson Date 2019-02-11 Time 12:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-30 Cont ID  
Sent By cpuell Date 2019-01-30 Time 10:39 Rev Time 0.00
Received By cpuell Date 2018-12-18 Time 14:21 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-01-23 Cont ID  
Sent By jwitmer Date 2019-01-23 Time 13:26 Rev Time 0.00
Received By jwitmer Date 2019-01-23 Time 13:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-05-03 Cont ID  
Sent By ccole Date 2019-05-03 Time 15:18 Rev Time 0.00
Received By ccole Date 2019-04-24 Time 13:13 Sent To  
Notes
2019-04-24 15:21:53MECHANICAL PROVISOS:
  
 A REVISION TO THE PLAN IS REQUIRED:
  
 1) RELOCATE THE OUTSIDE AIR INTAKES A MINIMUM 10'
 HORIZONTALLY AWAY FROM THE PARKING LOT AND DRIVEWAYS.
  
 2) PROVIDE EQUIPMENT SCHEDULES AND SPECS FOR EXISTING
 AC SYSTEMS.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-03-12 Cont ID  
Sent By ccole Date 2019-03-12 Time 15:32 Rev Time 0.00
Received By ccole Date 2019-03-12 Time 15:18 Sent To  
Notes
2019-03-12 16:59:24MECHANICAL PROVISOS LISTED ON APPROVED SHEET M1.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-01-18 Cont ID  
Sent By ccole Date 2019-01-18 Time 16:22 Rev Time 0.00
Received By ccole Date 2019-01-18 Time 16:03 Sent To  
Notes
2019-01-18 16:44:101ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18120675
 1/18/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1: CLARIFY THE NEED TO HAVE EXHAUST
 VENTILATION IN THE RETAIL AREA, AND PROVIDE AN EXHAUST
 VENTILATION CALCULATION TO SHOW HOW EF-6 WAS SIZED-
 SECTION 403.3 FBC M.
  
 2) M1 & M3: 420 CFMS OF EXHAUST IS SHOWN IN THE AIR
 BALANCE CALC AS THE VENTILATION REQUIRED RATE FOR THE
 RETAIL AREA, HOWEVER THE SCHEDULE INDICATES A FAN WITH
 A CAPACITY OF 1395 CFMS. CLARIFY THE NEED FOR SUCH A
 LARGE FAN- SECTION 107.2.1 WPB.
  
 3) REFER TO SECTION C403.2.7 FBC EC AND PROVIDE AN
 ENERGY RECOVERY VENTILATOR FOR THE EF-6/AHU-5 SYSTEM.
  
 4) SUBMIT FL. PRODUCT APPROVALS OR MIAMI-DADE NOA'S FOR
 THE LOUVERS AND GRAVITY VENTILATORS- RULE 9N-3 FAC.
  
 5) INDICATE THE TYPE OF EXISTING DOORS THAT ARE
 ENCLOSING THE AIR HANDLER CLOSETS- SEE SECTION 602.2
 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-04-19 Cont ID  
Sent By gjohnson Date 2019-04-19 Time 13:30 Rev Time 0.00
Received By gjohnson Date 2019-04-19 Time 13:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-03-14 Cont ID  
Sent By gjohnson Date 2019-03-14 Time 11:22 Rev Time 0.00
Received By gjohnson Date 2019-03-14 Time 11:22 Sent To  
Notes
2019-03-14 12:04:22 
  
 2ND REVIEW: 18120675
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:PREVIOUS COMMENTS 2ND REQUEST
  
 NOT COMPLIED 1. PLEASE SHOW DIMENSIONS ON THE CLEAR
 FLOOR SPACE FOR THE TOILET AND LAVATORY. PER FBC ACC
 604.3.1, 606.2
  
 NOT COMPLIED 4. MIRRORS LOCATED ABOVE LAVATORIES OR
 COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF
 THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND. PER FBC ACC 603.3
  
 PARCIALY COMPLIED 5. TOILET PAPER DISPENSERS SHALL
 COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9
 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES MINIMUM AND 48 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR. PER FBC ACC 604.7
 HIEGHT DIMENSION IS NOT SHOWN.
  
 NOT COMPLIED 7. GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE. FBC ACC 609.4
  
 NOT COMPLIED 8. THE WATER CLOSET SHALL BE POSITIONED
 WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE.
 THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES
 MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR
 PARTITION. PER FBC ACC 604.2
  
 NOT COMPLIED 9. SHOW CLEAR FLOOR SPACE FOR THE BREAK
 ROOM SINK AND ONE OF THE EXAM ROOM SINKS WITH THE SPACE
 BEING CENTERED ON THE FIXTURE. PER FBC ACC 212.3
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-01-24 Cont ID  
Sent By gjohnson Date 2019-01-24 Time 15:45 Rev Time 0.00
Received By gjohnson Date 2019-01-24 Time 13:01 Sent To  
Notes
2019-01-24 18:10:04 
  
 1ST REVIEW: 18120675
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE SHOW DIMENSIONS ON THE CLEAR FLOOR SPACE FOR
 THE TOILET AND LAVATORY. PER FBC ACC 604.3.1, 606.2
  
 1. THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH
 FLOOR SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUM
 MEASURED TO THE TOP OF THE SEAT.PER FBC ACC 604.4
  
 2. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE REAR WALL
 AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL. PER
 FBC ACC 604.5.1
  
 3. THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES (610
 MM) MINIMUM ON THE OTHER SIDE. PER FBC ACC 604.5.2
  
 4. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND. PER FBC ACC 603.3
  
 5. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR. PER FBC ACC 604.7
  
 6. LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE
 FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34
 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. PER
 FBC ACC 606.3
  
 7. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE. FBC ACC 609.4
  
 8. THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18
 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION. PER FBC
 ACC 604.2
  
 9. SHOW CLEAR FLOOR SPACE FOR THE BREAK ROOM SINK AND
 ONE OF THE EXAM ROOM SINKS WITH THE SPACE BEING
 CENTERED ON THE FIXTURE. PER FBC ACC 212.3
  
 10. PLEASE PROVIDE MANUFACTURE SPECIFICATIONS FOR THE
 REMOTE CHILLER. PER WPB AMEND TO FBC 107.2.1
  
 11. SHOW SHUT OF VALVES ON THE RISER FOR ALL THE DROPS
 PER FBC PL 212.3 (5)
  
 12. IF NEW BACKFLOW IS INSTALLED AT METER A SEPARATE
 PERMIT WILL BE REQUIRED A NOTE ON THE PLAN WILL
 SUFFICE. PER WPB UTILITIES DEPT.
  
 13.NOTE ON PLAN WHAT TYPE OF ANCHORS ARE TO BE USED FOR
 THE WATER HEATER BRACKET TO HOLD A MIN OF 500LB. PER
 PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-05-02 Cont ID  
Sent By pvalenti Date 2019-05-02 Time 08:20 Rev Time 0.00
Received By pvalenti Date 2019-05-02 Time 08:20 Sent To  
Notes
2019-04-24 15:25:46NEW MECH SHEETS GOOD.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-03-12 Cont ID  
Sent By shill Date 2019-03-12 Time 16:07 Rev Time 0.00
Received By shill Date 2019-03-12 Time 16:07 Sent To  
Notes
2019-03-12 16:08:42SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 DIGITAL SIGNATURES ARE OK, ALL TRADES
 NEW SHEETS SUBMITTED NEXT REVIEW CYCLE NEED
 VERIFICATION

Review Stop Z ZONING
Rev No 3 Status P Date 2019-04-11 Cont ID  
Sent By mcruz Date 2019-04-11 Time 16:05 Rev Time 0.00
Received By mcruz Date 2019-04-11 Time 16:00 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2019-02-19 Cont ID  
Sent By mcruz Date 2019-02-19 Time 13:45 Rev Time 0.00
Received By mcruz Date 2019-02-19 Time 13:40 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-01-29 Cont ID  
Sent By mcurz Date 2019-01-29 Time 15:26 Rev Time 0.00
Received By ajones Date 2019-01-03 Time 11:50 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved