Plan Review Details - Permit 18120653
Plan Review Stops For Permit 18120653
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-06-28 Cont ID  
Sent By dbattles Date 2019-06-28 Time 16:53 Rev Time 0.00
Received By dbattles Date 2019-06-28 Time 16:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-21 Cont ID  
Sent By dbattles Date 2019-05-21 Time 10:16 Rev Time 0.00
Received By dbattles Date 2019-05-21 Time 10:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-31 Cont ID  
Sent By dbattles Date 2019-01-31 Time 16:29 Rev Time 0.00
Received By dbattles Date 2019-01-31 Time 11:23 Sent To  
Notes
2019-01-31 16:31:36****CORRECTIONS****
 W.P.B. PERMIT: 18120653
 REVIEWED: JANUARY 31, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1. 401.2 FBC[RE] THE ENERGY CALCULATION CALL FOR
 UNVENTED ROOF/CEILING BUT THE PLANS SHOW VENTED. PLEASE
 CO-ORDINATE WHICH METHOD IS BEING USED.
  
 IF USING UNVENTED ATTIC AND UNVENTED ENCLOSED RAFTER
 ASSEMBLIES, SEE 806.5 FBC[R] FOR REQUIREMENTS.
  
 IF VENTING THAN ACCOUNT FOR CLEAR SPACE AT ROOF DECK.
 806.3 FBC[R] VENT AND INSULATION CLEARANCE. WHERE EAVE
 OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT
 BLOCK THE FREE FLOW OF AIR. NOT LESS THAN A 1-INCH (25
 MM) SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND
 THE ROOF SHEATHING AND AT THE LOCATION OF THE VENT.
  
 103.1.1.2 FBC[RE] PLEASE UPDATE THE ENERGY CALCULATIONS
 AS APPLICABLE AND HAVE THE OWNER OR AGENT SIGN THEM
 UNDER THE SIGNATURE OF THE PREPARER.
  
 2. 403.1.1 FBC[R] MINIMUM SIZE. THE MINIMUM WIDTH, W,
 AND THICKNESS, T, FOR CONCRETE FOOTINGS SHALL BE IN
 ACCORDANCE WITH TABLES R403.1(1) THROUGH R403.1(3) AND
 FIGURE R403.1(1) AS APPLICABLE. MINIMUM SIZES FOR
 CONCRETE AND MASONRY FOOTINGS SHALL ALSO BE REQUIRED TO
 PROVIDE ADEQUATE RESISTANCE TO UPLIFT AND OVERTURN OF
 THE BUILDING AS DETERMINED FROM TABLE R401.1 AND
 SECTION R403.1.2 OR AS CALCULATED USING ENGINEERED
 DESIGN IN ACCORDANCE WITH THE FLORIDA BUILDING CODE,
 BUILDING. THE FOOTING WIDTH SHALL BE BASED ON THE
 LOAD-BEARING VALUE OF THE SOIL IN ACCORDANCE WITH TABLE
 R401.4.1.
 403.1.4 FBC[R] MINIMUM DEPTH. EXTERIOR FOOTINGS SHALL
 BE PLACED NOT LESS THAN 12 INCHES (305 MM) BELOW THE
 UNDISTURBED GROUND SURFACE.
  -WHAT IS THE THICKNESS OF EXISTING SLAB AND HOW WILL
 IT MEET 403.1.1 FOR MINIMUM SIZE?
  
 3. 506.2.3 FBC[R] VAPOR RETARDER. A 6-MIL (0.006 INCH)
 POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS
 LAPPED NOT LESS THAN 6 INCHES (152 MM) SHALL BE PLACED
 BETWEEN THE CONCRETE FLOOR SLAB AND THE BASE COURSE OR
 THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS.
 -WILL A VAPOR BARRIER BE PROVIDED BETWEEN EXISTING AND
 NEW CONCRTET TOPPING?
  
 4. 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS
 WINDOW MULL.
  
 5. 301.2.1.2 FBC[R] PROTECTION OF OPENINGS.
  -PROVIDE NOTES/DETAILS FOR PROTECTION FROM WINDBORNE
 DEBRIS TO ALL EXTERIOR OPENINGS INCLUDING WINDOWS.
 THE PRODUCT APPROVAL SUBMITTED FOR WINDOWS IS NOT
 IMPACT RATED. --PLEASE PROVIDE PRODUCT APPROVAL FOR
 IMPACT PROTECTION.
 ALSO, NOTE THAT THE FIBERGLASS DOOR IS APPROVED IMPACT
 AS LONG AS ANY GLASS IN THE DOOR IS IMPACT RATED OR
 OPAQUE PANEL.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-06-03 Cont ID  
Sent By jpearson Date 2019-06-03 Time 10:20 Rev Time 0.00
Received By jpearson Date 2019-06-03 Time 06:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-01-09 Cont ID  
Sent By jpearson Date 2019-01-09 Time 07:24 Rev Time 0.00
Received By cthroop Date 2019-01-24 Time 17:02 Sent To  
Notes
2019-01-09 06:48:19PASSED WITH PROVISO ON PLAN.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-06-28 Cont ID  
Sent By hmoser Date 2019-06-28 Time 16:54 Rev Time  
Received By dbattles Date 2019-06-25 Time 13:39 Sent To  
Notes
2019-06-27 13:40:02RESUB ROUTED TO HMOSER'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-07 Cont ID  
Sent By cpuell Date 2019-06-07 Time 09:29 Rev Time 0.00
Received By cpuell Date 2019-05-14 Time 13:46 Sent To  
Notes
2019-05-15 13:47:03R39

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-01 Cont ID  
Sent By hmoser Date 2019-02-01 Time 10:34 Rev Time 0.00
Received By hmoser Date 2018-12-18 Time 13:14 Sent To  
Notes
2018-12-19 13:15:06R19

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-07-11 Cont ID  
Sent By dbattles Date 2019-07-11 Time 11:43 Rev Time 0.00
Received By dbattles Date 2019-07-11 Time 11:43 Sent To  
Notes
2019-07-11 11:44:41OK-STAMP ON PLANS
 MU-2019-021193-0000

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-01-31 Cont ID  
Sent By dbattles Date 2019-01-31 Time 16:31 Rev Time 0.00
Received By dbattles Date 2019-01-31 Time 11:23 Sent To  
Notes
2019-01-31 16:32:15109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU
 MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-06-28 Cont ID  
Sent By hmoser Date 2019-06-28 Time 13:11 Rev Time 0.00
Received By hmoser Date 2019-06-28 Time 13:11 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-05-25 Cont ID  
Sent By cmontell Date 2019-05-25 Time 05:01 Rev Time 0.00
Received By cmontell Date 2019-05-25 Time 04:57 Sent To  
Notes
2019-05-25 04:57:55PLAN DENIED
 REFER TO SECTION R103.1.1.2 FLORIDA ENERGY CODE
 OWNER/ AGENT MUST SIGN ENERGY CALCULATIONS.
  
 CHRIS MONTELLO
 805-6733

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-02-01 Cont ID  
Sent By hmoser Date 2019-02-01 Time 10:34 Rev Time 0.00
Received By hmoser Date 2019-01-29 Time 09:50 Sent To I
Notes
2019-02-01 10:34:12PLAN DENIED
 REFER TO SECTION R103.1.1.2 FLORIDA ENERGY CODE
 OWNER/ AGENT MUST SIGN ENERGY CALCULATIONS.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop Z ZONING
Rev No 2 Status P Date 2019-06-06 Cont ID  
Sent By awooten Date 2019-06-06 Time   Rev Time 0.00
Received By awooten Date 2019-06-06 Time   Sent To  
Notes
2019-06-06 15:32:45INTERIOR REMODEL, THE FOOTPRINT IS NOT CHANGING.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISON
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2019-01-04 Cont ID  
Sent By awooten Date 2019-01-04 Time   Rev Time  
Received By awooten Date 2019-01-04 Time   Sent To  
Notes
2019-01-04 14:16:01**************************************ZONING REVIEW
 FAILED*************************************
  
 PROVIDE A COPY OF THE SURVEY OF THE PROPERTY.
  
 ALANA WOOTEN
 ASSOIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]