| Plan Review Stops For Permit 18120597 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-24 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-24 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-12-18 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-12-18 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2018-12-18 10:34:58 | W. P. B. PERMIT: 18120597/ FOUNDATION. | | | ADD: 1831 PALM BEACH LAKES BLVD. | | | CONT: TBD/ TO BE DETERMINED | | | TEL: ??????? / KARI NEVILLE | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | | | | 1ST REVIEW | | | DATE: TUES. DEC. 18/2018 | | | ACTION: DENIED | | | FOUNDATION PERMIT. | | | | | | 1) SHEET 004-A100 SITE PLAN. PLEASE NOTE THERE IS NO | | | PROPERTY LINES OR ASSUMED PROPERTY LINES DESIGNATING | | | WHERE AN ASSUMED PROPERTY LINE WOULD BE ASSUMED FOR | | | COMPLIANCE WITH 2017 FBC-B TABLE 602 FIRE RESISTANCE | | | RATING OF EXTERIOR WALLS BASED ON FIRE SEPARATION | | | DISTANCE AND TABLE 705.8 MAXIMUM ALLOWABLE WINDOW | | | OPENINGS VERSES FIRE SEPARATION DISTANCE AND DEGREE OF | | | OPENING PROTECTION. | | | | | | 2) SHEET 028-S000. GENERAL NOTES. FOUNDATIONS) NOTE # 1 | | | INDICATES THE FOUNDATION DESIGN WAS BASED ON THE | | | GEOTECHNICAL REPORT BY ARDAMAN & ASSOCIATES, INC. DATED | | | JUNE 28, 2016. PLEASE SUBMIT EITHER DIGITAL REPORT WITH | | | AN ELECTRONIC SIGNATURE OR 1 PAPER REPORT WITH AN | | | ORIGINAL SIGNATURE, DATE AND SEAL. | | | 61G15-23.002 ENGINEER SEAL SIGNATURE AND DATE SHALL BE | | | AFFIXED, (PAPER). | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | | REPORTS OR OTHER DOCUMENTS. | | | | | | 3) BEFORE THE SHELL BUILDING CAN HAVE THE PERMIT | | | ISSUED, THE PLANS WILL NEED TO GO TO PALM BEACH COUNTY. | | | ONE SET OF PLANS WILL HAVE TO BE TAKEN (BY THE | | | CONTRACTOR OR REPRESENTATIVE) TO THE PALM BEACH COUNTY | | | IMPACT FEE OFFICE LOCATED AT 2300 N. JOG RD. ROOMS? | | | 2W01-2W14 WEST PALM BEACH, FL. THE ACTUAL PERMIT SET OF | | | PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE | | | PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE | | | CALL (561)233-5025 FOR MORE INFORMATION. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-02-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-03 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-03 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-24 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-24 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2019-01-24 08:52:06 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NO ELECTRICAL ISSUES FOR FOUNDATION. CANNOT APPROVE | | | AND STAMP PLAN UNTIL SIGNATURE ISSUES RESOLVED. SEE | | | SIGNATURE COMMENTS. WPB FBC 105.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-12-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-23 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-23 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2018-12-23 11:00:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | | FBC 107.2.1, 107.3.5; FS 471, 481 | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30 | | | 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-01-24 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2019-01-24 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2019-01-24 17:52:03 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION IF REQUIRED | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-21 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2018-12-21 18:51:26 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION IF REQUIRED | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-01-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-01-17 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-01-17 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-12-18 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-12-18 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-06 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-31 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-01-30 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-16 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-01-08 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-12-17 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-06 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-06 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-01-24 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-01-24 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2019-01-24 11:41:04 | WAITING FOR MASTER PERMIT PASS PALM BEACH COUNTY IMPACT | | | FEE |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-12-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-26 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-26 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2018-12-26 11:02:51 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-12-18 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-12-18 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2018-12-18 10:34:07 | BEFORE THE SHELL BUILDING CAN HAVE THE PERMIT ISSUED, | | | THE PLANS WILL NEED TO GO TO PALM BEACH COUNTY. ONE SET | | | OF PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS? 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-28 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-28 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-02-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-03 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-03 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2019-02-03 08:35:50 | PASSED BASED ON PAPER SIGNATURES PROVIDED. | | | | | | | | 2019-02-01 15:24:00 | 2/1/19 PAPER SIGNATURES SUBMITTED IN LIBRARY FOR | | | VERIFICATION. CP | | 2019-01-31 15:56:14 | 1/31/19 APPLICANT WILL SUBMIT HARD COPIES ON 2/1. LEM |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-24 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-24 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2019-01-24 07:47:34 | EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED | | | BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL | | | PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD | | | PARTY VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1; | | | FS 471/481 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-21 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2018-12-21 18:54:32 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | C SHEETS NOT DIGITALLY SIGNED | | | A SHEETS NOT DIGITALLY SIGNED | | | S SHEETS OK | | | MEP ENGINEER PAGES LACK A TITLE BLOCK AND THE DIGITAL | | | SIGNATURE IS CORRUPT | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-02-05 |
Time |
16:50 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-02-05 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2019-02-05 16:52:03 | 1) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | | | A. PARKING LOT RECONFIGURATION AND STRIPING. | | | B. DUMPSTER ENCLOSURE. | | | C. ATM | | | D. BICYCLE RACK | | | E. LANDSCAPE | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-01-29 |
Time |
15:19 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2019-01-29 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2019-01-29 15:20:26 | FAILED | | | | | | 1) REPEAT COMMENT- PROVIDE THE BUILDING SETBACKS ON THE | | | FOUNDATION PLAN. **** THE PLANS DO NOT SHOW A DIMENSION | | | LINE(S) FROM THE BUILDING TO THE PROPERTY LINE. | | | | | | 2) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | | | A. PARKING LOT RECONFIGURATION AND STRIPING. | | | B. DUMPSTER ENCLOSURE. | | | C. ATM | | | D. BICYCLE RACK | | | E. LANDSCAPE | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-01-08 |
Time |
14:25 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2019-01-08 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2019-01-08 14:27:03 | FAILED | | | | | | 1) PROVIDE THE BUILDING SETBACKS ON THE FOUNDATION | | | PLAN. | | | | | | 2) THE NEW LOCATION OF THE WATER AND FIRE SERVICES | | | DIRECTLY CONFLICT WITH THE LOCATION OF AN APPROVED DATE | | | PALM. THE DATE PALM SERVES AS A BUFFER TREE AND MAY NOT | | | BE RELOCATED FROM THIS APPROVED LOCATION. | | | | | | 3) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | | | A. PARKING LOT RECONFIGURATION AND STRIPING. | | | B. DUMPSTER ENCLOSURE. | | | C. ATM | | | D. BICYCLE RACK | | | E. LANDSCAPE | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|