Plan Review Details - Permit 18120597
Plan Review Stops For Permit 18120597
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-01-24 Cont ID  
Sent By jduprey Date 2019-01-24 Time 11:42 Rev Time 0.00
Received By jduprey Date 2019-01-24 Time 09:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-18 Cont ID  
Sent By jwitmer Date 2018-12-18 Time 10:35 Rev Time 0.00
Received By jwitmer Date 2018-12-18 Time 10:25 Sent To  
Notes
2018-12-18 10:34:58W. P. B. PERMIT: 18120597/ FOUNDATION.
 ADD: 1831 PALM BEACH LAKES BLVD.
 CONT: TBD/ TO BE DETERMINED
 TEL: ??????? / KARI NEVILLE
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
  
 1ST REVIEW
 DATE: TUES. DEC. 18/2018
 ACTION: DENIED
 FOUNDATION PERMIT.
  
 1) SHEET 004-A100 SITE PLAN. PLEASE NOTE THERE IS NO
 PROPERTY LINES OR ASSUMED PROPERTY LINES DESIGNATING
 WHERE AN ASSUMED PROPERTY LINE WOULD BE ASSUMED FOR
 COMPLIANCE WITH 2017 FBC-B TABLE 602 FIRE RESISTANCE
 RATING OF EXTERIOR WALLS BASED ON FIRE SEPARATION
 DISTANCE AND TABLE 705.8 MAXIMUM ALLOWABLE WINDOW
 OPENINGS VERSES FIRE SEPARATION DISTANCE AND DEGREE OF
 OPENING PROTECTION.
  
 2) SHEET 028-S000. GENERAL NOTES. FOUNDATIONS) NOTE # 1
 INDICATES THE FOUNDATION DESIGN WAS BASED ON THE
 GEOTECHNICAL REPORT BY ARDAMAN & ASSOCIATES, INC. DATED
 JUNE 28, 2016. PLEASE SUBMIT EITHER DIGITAL REPORT WITH
 AN ELECTRONIC SIGNATURE OR 1 PAPER REPORT WITH AN
 ORIGINAL SIGNATURE, DATE AND SEAL.
 61G15-23.002 ENGINEER SEAL SIGNATURE AND DATE SHALL BE
 AFFIXED, (PAPER).
 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS,
 REPORTS OR OTHER DOCUMENTS.
  
 3) BEFORE THE SHELL BUILDING CAN HAVE THE PERMIT
 ISSUED, THE PLANS WILL NEED TO GO TO PALM BEACH COUNTY.
 ONE SET OF PLANS WILL HAVE TO BE TAKEN (BY THE
 CONTRACTOR OR REPRESENTATIVE) TO THE PALM BEACH COUNTY
 IMPACT FEE OFFICE LOCATED AT 2300 N. JOG RD. ROOMS?
 2W01-2W14 WEST PALM BEACH, FL. THE ACTUAL PERMIT SET OF
 PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE
 PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE
 CALL (561)233-5025 FOR MORE INFORMATION.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-02-03 Cont ID  
Sent By jpearson Date 2019-02-03 Time 08:36 Rev Time 0.00
Received By jpearson Date 2019-02-03 Time 08:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-01-24 Cont ID  
Sent By jpearson Date 2019-01-24 Time 08:52 Rev Time 0.00
Received By jpearson Date 2019-01-24 Time 08:52 Sent To  
Notes
2019-01-24 08:52:06CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NO ELECTRICAL ISSUES FOR FOUNDATION. CANNOT APPROVE
 AND STAMP PLAN UNTIL SIGNATURE ISSUES RESOLVED. SEE
 SIGNATURE COMMENTS. WPB FBC 105.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-12-23 Cont ID  
Sent By jpearson Date 2018-12-23 Time 11:00 Rev Time 0.00
Received By jpearson Date 2018-12-23 Time 11:00 Sent To  
Notes
2018-12-23 11:00:03CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB
 FBC 107.2.1, 107.3.5; FS 471, 481
 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30
 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. NEC 220
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2019-01-24 Cont ID  
Sent By shill Date 2019-01-24 Time 17:51 Rev Time 0.00
Received By mgonzale Date 2019-01-24 Time 17:51 Sent To  
Notes
2019-01-24 17:52:03CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-12-21 Cont ID  
Sent By shill Date 2018-12-21 Time 18:51 Rev Time 0.00
Received By shill Date 2018-12-21 Time 18:51 Sent To  
Notes
2018-12-21 18:51:26CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-01-17 Cont ID  
Sent By scaldero Date 2019-01-17 Time 14:11 Rev Time 0.00
Received By scaldero Date 2019-01-17 Time 14:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-12-18 Cont ID  
Sent By scaldero Date 2018-12-18 Time 10:01 Rev Time 0.00
Received By scaldero Date 2018-12-18 Time 09:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-02-06 Cont ID  
Sent By jduprey Date 2019-02-06 Time 08:08 Rev Time 0.00
Received By jduprey Date 2019-01-31 Time 15:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-30 Cont ID  
Sent By lmarchan Date 2019-01-30 Time 09:43 Rev Time 0.00
Received By lmarchan Date 2019-01-16 Time 13:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-08 Cont ID  
Sent By lmarchan Date 2019-01-08 Time 16:40 Rev Time 0.00
Received By lmarchan Date 2018-12-17 Time 14:00 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2019-02-06 Cont ID  
Sent By jduprey Date 2019-02-06 Time 08:05 Rev Time 0.00
Received By jduprey Date 2019-02-06 Time 08:05 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2019-01-24 Cont ID  
Sent By shill Date 2019-01-24 Time 17:52 Rev Time 0.00
Received By shill Date 2019-01-24 Time 17:52 Sent To  
Notes
2019-01-24 11:41:04WAITING FOR MASTER PERMIT PASS PALM BEACH COUNTY IMPACT
 FEE

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2018-12-26 Cont ID  
Sent By shill Date 2018-12-26 Time 11:02 Rev Time 0.00
Received By shill Date 2018-12-26 Time 11:02 Sent To  
Notes
2018-12-26 11:02:51PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-12-18 Cont ID  
Sent By jwitmer Date 2018-12-18 Time 10:34 Rev Time 0.00
Received By jwitmer Date 2018-12-18 Time 10:26 Sent To  
Notes
2018-12-18 10:34:07BEFORE THE SHELL BUILDING CAN HAVE THE PERMIT ISSUED,
 THE PLANS WILL NEED TO GO TO PALM BEACH COUNTY. ONE SET
 OF PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR
 REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE
 OFFICE LOCATED AT 2300 N. JOG RD. ROOMS? 2W01-2W14 WEST
 PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE
 STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL
 (561)233-5025 FOR MORE INFORMATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-12-28 Cont ID  
Sent By gjohnson Date 2018-12-28 Time 10:02 Rev Time 0.00
Received By gjohnson Date 2018-12-28 Time 09:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-02-03 Cont ID  
Sent By jpearson Date 2019-02-03 Time 08:36 Rev Time 0.00
Received By jpearson Date 2019-02-03 Time 08:35 Sent To  
Notes
2019-02-03 08:35:50PASSED BASED ON PAPER SIGNATURES PROVIDED.
  
  
2019-02-01 15:24:002/1/19 PAPER SIGNATURES SUBMITTED IN LIBRARY FOR
 VERIFICATION. CP
2019-01-31 15:56:141/31/19 APPLICANT WILL SUBMIT HARD COPIES ON 2/1. LEM

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-01-24 Cont ID  
Sent By jpearson Date 2019-01-24 Time 07:47 Rev Time 0.00
Received By jpearson Date 2019-01-24 Time 07:47 Sent To  
Notes
2019-01-24 07:47:34EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED
 BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL
 PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD
 PARTY VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1;
 FS 471/481

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-12-21 Cont ID  
Sent By shill Date 2018-12-21 Time 18:51 Rev Time 0.00
Received By shill Date 2018-12-21 Time 18:51 Sent To  
Notes
2018-12-21 18:54:32****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 C SHEETS NOT DIGITALLY SIGNED
 A SHEETS NOT DIGITALLY SIGNED
 S SHEETS OK
 MEP ENGINEER PAGES LACK A TITLE BLOCK AND THE DIGITAL
 SIGNATURE IS CORRUPT
  

Review Stop Z ZONING
Rev No 3 Status P Date 2019-02-05 Cont ID  
Sent By eschneid Date 2019-02-05 Time 16:50 Rev Time 0.25
Received By eschneid Date 2019-02-05 Time 16:36 Sent To  
Notes
2019-02-05 16:52:031) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING:
  
 A. PARKING LOT RECONFIGURATION AND STRIPING.
 B. DUMPSTER ENCLOSURE.
 C. ATM
 D. BICYCLE RACK
 E. LANDSCAPE
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2019-01-29 Cont ID  
Sent By eschneid Date 2019-01-29 Time 15:19 Rev Time 1.00
Received By eschneid Date 2019-01-29 Time 15:19 Sent To  
Notes
2019-01-29 15:20:26FAILED
  
 1) REPEAT COMMENT- PROVIDE THE BUILDING SETBACKS ON THE
 FOUNDATION PLAN. **** THE PLANS DO NOT SHOW A DIMENSION
 LINE(S) FROM THE BUILDING TO THE PROPERTY LINE.
  
 2) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING:
  
 A. PARKING LOT RECONFIGURATION AND STRIPING.
 B. DUMPSTER ENCLOSURE.
 C. ATM
 D. BICYCLE RACK
 E. LANDSCAPE
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-01-08 Cont ID  
Sent By eschneid Date 2019-01-08 Time 14:25 Rev Time 0.75
Received By eschneid Date 2019-01-08 Time 14:25 Sent To  
Notes
2019-01-08 14:27:03FAILED
  
 1) PROVIDE THE BUILDING SETBACKS ON THE FOUNDATION
 PLAN.
  
 2) THE NEW LOCATION OF THE WATER AND FIRE SERVICES
 DIRECTLY CONFLICT WITH THE LOCATION OF AN APPROVED DATE
 PALM. THE DATE PALM SERVES AS A BUFFER TREE AND MAY NOT
 BE RELOCATED FROM THIS APPROVED LOCATION.
  
 3) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING:
  
 A. PARKING LOT RECONFIGURATION AND STRIPING.
 B. DUMPSTER ENCLOSURE.
 C. ATM
 D. BICYCLE RACK
 E. LANDSCAPE
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446