Plan Review Details - Permit 18120442
Plan Review Stops For Permit 18120442
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-04-17 Cont ID  
Sent By jduprey Date 2019-04-17 Time 08:37 Rev Time 0.00
Received By jduprey Date 2019-04-17 Time 08:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-02 Cont ID  
Sent By pvalenti Date 2019-01-02 Time 11:11 Rev Time 0.00
Received By pvalenti Date 2019-01-02 Time 11:11 Sent To Z
Notes
2019-01-02 11:34:29****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 FBC 107. THE MOUNTING INFORMATION APPEARS TO SHOW
 SECURITY GRILL FRAMING MEMBERS ATTACHING TO THE
 EXISTING STORE FRONT FRAMING MEMBERS. THE EXISTING
 STORE FRONT FRAMING MEMBERS WERE NOT APPROVED FOR THESE
 ATTACHMENTS.
  
 PLEASE RESUBMIT PLANS SHOWING APPROVED ATTACHMENTS TO
 EXISTING STRUCTURE, INDEPENDANT OF EXISTING STORE FRONT
 SYSTEM AND PROVIDE PRODUCT APPROVALS/MANUFACTURER'S
 INSTRUCTIONS.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY
 RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-04-16 Cont ID  
Sent By scaldero Date 2019-04-16 Time 10:13 Rev Time 0.00
Received By scaldero Date 2019-04-16 Time 10:13 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-01-10 Cont ID  
Sent By scaldero Date 2019-01-10 Time 10:56 Rev Time 0.00
Received By scaldero Date 2019-01-10 Time 10:56 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-04-17 Cont ID  
Sent By jduprey Date 2019-04-17 Time 08:37 Rev Time 0.00
Received By jduprey Date 2019-04-04 Time 14:19 Sent To  
Notes
2019-04-04 14:19:15RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-10 Cont ID  
Sent By cpuell Date 2019-01-10 Time 12:36 Rev Time 0.00
Received By cpuell Date 2018-12-12 Time 15:12 Sent To  
Notes
2018-12-13 15:12:31BLDG MISC 1

Review Stop Z ZONING
Rev No 2 Status P Date 2019-04-11 Cont ID  
Sent By mcruz Date 2019-04-11 Time 15:22 Rev Time 0.00
Received By mcruz Date 2019-04-11 Time 15:22 Sent To FIRE
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-01-04 Cont ID  
Sent By mcruz Date 2019-01-04 Time 09:37 Rev Time 0.00
Received By mcruz Date 2019-01-04 Time 08:23 Sent To FIRE
Notes
***NONE***