| 2018-12-29 10:35:11 | ****CORRECTIONS**** |
| | |
| | PETER E VALENTI |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6673 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A |
| | DEMO PERMIT: |
| | 1. FBC B 107.2.1, PROVIDE ARCHITECT/ENGINEER APPROVAL |
| | LETTER FOR FOOTINGS SUPPORTING EXISTING BUILDING. CITY |
| | INSPECTORS WHO HAVE VISITED THE SITE HAVE CONCERNS |
| | ABOUT THE STRUCTURAL INTEGRITY OF THE EXISTING |
| | STRUCTURE AND HOW IT MAY HAVE BEEN COMPROMISED BY |
| | UNPERMITTED WORK. CALCULATIONS MAY BE REQUIRED. |
| | 2. FBC B 105.4.1.2, SEE EXPIRED PERMIT APPLICATION |
| | 14040355. IT APPEARS THAT GAS WORK WAS DONE WITHOUT A |
| | PERMIT. IF WORK HAS BEEN REMOVED, A GAS PERMIT IS |
| | REQUIRED BY A LICENSED CONTRACTOR SO PROPER AND SAFE |
| | REMOVAL CAN BE CONFIRMED BY THE LICENSED CONTRACTOR AND |
| | INSPECTED BY THE CITY INSPECTOR. THIS CAN BE DONE AS A |
| | SUB PERMIT TO THIS MASTER PERMIT. THE SUB PERMIT CAN BE |
| | EMAILED TO [email protected]; THE ORIGINAL WILL BE |
| | REQUIRED AT TIME OF PICKUP. REVISE PLAN TO INDICATE |
| | REMOVAL. PLEASE INCLUDE A REFERENCE TO THIS PERMIT |
| | NUMBER IN THE EMAIL SUBJECT LINE. |
| | IF GAS WORK PROPOSED UNDER 14040355 WAS INSTALLED AND |
| | IS TO REMAIN, PROVIDE A PLAN AND GAS PERMIT |
| | APPLICATION. |
| | 3. FBC B 105.4 & FBC B 105.5, PLEASE ADVISE STATUS OF |
| | THE GREASE TRAP INSTALLED UNDER PERMIT 15070296. IF |
| | THIS IS STILL INSTALLED, APPLY FOR A ?FINAL INSPECTION |
| | ONLY? PERMIT AT THE BUILDING DIVISION. THE DESCRIPTION |
| | WILL BE ?FINAL INSPECTION ONLY TO CLOSE OUT EXPIRED |
| | PERMIT 15070296?. A CONTRACTOR IS NOT REQUIRED IF ALL |
| | WORK WAS PREVIOUSLY PERFORMED BY THE LICENSED |
| | CONTRACTOR. |
| | IF THE GREASE TRAP WAS REMOVED, REVISE PLAN TO INDICATE |
| | SUCH. |
| | 4. EXTERMINATION LETTER- PROVIDE A LETTER FROM A |
| | PROFESSIONAL EXTERMINATING COMPANY STATING THAT THE |
| | PROPERTY HAS BEEN INSPECTED AND OR TREATED FOR RODENTS. |
| | 5. COMPLETE THE DEMO DEBRIS FORM AND PAY THE FEES, |
| | ?DEMO DEBRIS DISPOSAL FEE? |
| | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| | UILDING-PERMIT-FORMS |
| | AFTER THE FORM IS SENT TO [email protected], THE FEES |
| | WILL BE ADDED TO YOUR PERMIT. YOU CAN THEN PAY THE FEES |
| | ONLINE PRIOR TO PERMIT ISSUANCE. |
| | 6. FBC B 105.4 & FBC B 105.5, THERE ARE TWO EXPIRED |
| | PERMITS FOR THIS ADDRESS; 14030860 MECHANICAL HOOD, AND |
| | 14030861, HOOD SUPPRESSION. IF WORK HAS BEEN REMOVED, |
| | REVISE PLAN |
| | TO INCORPORATE SCOPE INTO THIS PERMIT. IF WORK HAS NOT |
| | BEEN REMOVED, APPLY FOR NEW PERMITS SO THE WORK CAN BE |
| | INSPECTED AND FINALED. |
| | 7. FBC EB 504/505, THIS STRUCTURE IS LOCATED IN A |
| | SPECIAL FLOOD HAZARD AREA WITH A BFE OF 12.1, FREEBOARD |
| | OF 2?. IT IS NOT CLEAR IF THE IMPROVEMENTS DONE TO THIS |
| | STRUCTURE WILL CONSTITUTE A ?SUBSTANTIAL IMPROVEMENT?. |
| | PROVIDE THE VALUE OF THIS STRUCTURE. SEE SECTION 4.5 IN |
| | THE FOLLOWING DOCUMENT FOR ACCEPTABLE WAYS OF |
| | DETERMINING VALUE: |
| | HTTPS://WWW.FEMA.GOV/MEDIA-LIBRARY-DATA/20130726-1734-2 |
| | 5045-2915/P_758_COMPLETE_R3.PDF |
| | ALSO PROVIDE A COST BREAKDOWN FOR ALL PROPOSED WORK. |
| | |