| Plan Review Stops For Permit 18120237 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-15 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-15 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2019-02-15 15:40:33 | PERMIT NOT REQUIRED PER FBC 3103.1.2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-01-31 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-31 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-31 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2019-01-31 08:06:56 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE GAZEBO PRODUCT DATA SUBMITTED STATES THE GAZEBO | | | IS NOT INTENTED FOR USED IN STRUCTURES THAT TRAP WIND | | | OR RAIN THAT WOULD CREATE EXTRA LOAD ON THE PRODUCT. | | | THE FLORIDA RESIDENTIAL CODE CHAPTER R301.1 INDICATES | | | THAT BUILDINGS AND STRUCTURES, AND PARTS THEREOF, SHALL | | | BE CONSTRUCTED TO SAFELY SUPPORT ALL LOADS, INCLUDING | | | DEAD LOADS, LIVE LOADS, ROOF LOADS, FLOOD LOADS, SNOW | | | LOADS, WIND LOADS AND SEISMIC LOADS AS PRESCRIBED BY | | | THIS CODE. THE CONSTRUCTION OF BUILDINGS AND STRUCTURES | | | IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE SHALL | | | RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH | | | THAT MEETS THE REQUIREMENTS FOR THE TRANSFER OF LOADS | | | FROM THEIR POINT OF ORIGIN THROUGH THE LOAD-RESISTING | | | ELEMENTS TO THE FOUNDATION. BUILDINGS AND STRUCTURES | | | CONSTRUCTED AS PRESCRIBED BY THIS CODE ARE DEEMED TO | | | COMPLY WITH THE REQUIREMENTS OF THIS SECTION. | | | | | | 2. PLEASE PROVIDE A DIFFERENT PRODUCT TO MEET THE LOAD | | | REQUIREMENTS OF FLORIDA RESIDENTIAL CODE OR HAVE THE | | | GAZEBO SUBMITTED EVALUATED BY A FLORIDA LICENSE DESIGN | | | PROFESSIONAL. WE WANT TO SEE A GAZEBO THAT MEET THE | | | WIND LOADS REQUIREMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-14 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-14 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2019-01-14 15:12:43 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY | | | PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.PLEASE PROVIDE GAZEBO INFORMATION FBC107 | | | | | | 1.FOR PRE-ENGINEERED GAZEBO: | | | A.PROVIDE FOUNDATION PLAN. | | | B.PROVIDE PRE-ENGINEERED DESIGN. | | | C.IDENTIFY TYPE OF TIE-DOWN TO FOUNDATION. | | | | | | | | | 2.FOR SITE BUILT GAZEBO: | | | A.PROVIDE FOUNDATION PLAN FOOTINGS/SLAB ON | | | GRADE/REINFORCING | | | B.PROVIDE BUILDING PLANS | | | 1.FLOOR | | | 2.WALLS | | | 3.ROOF FRAMING | | | C.WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND | | | DESIGN WIND LOADS. | | | D.PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR | | | DOORS. >720 SQ. FT. | | | | | | | | | 2. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE | | | CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR, | | | MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. CITY OF | | | WPB CHAPTER 1 VALUE 109.3 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-02 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-02 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2019-01-02 09:28:06 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY | | | PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.PLEASE PROVIDE GAZEBO INFORMATION FBC107 | | | | | | 1.FOR PRE-ENGINEERED GAZEBO: | | | A.PROVIDE FOUNDATION PLAN. | | | B.PROVIDE PRE-ENGINEERED DESIGN. | | | C.IDENTIFY TYPE OF TIE-DOWN TO FOUNDATION. | | | | | | | | | 2.FOR SITE BUILT GAZEBO: | | | A.PROVIDE FOUNDATION PLAN FOOTINGS/SLAB ON | | | GRADE/REINFORCING | | | B.PROVIDE BUILDING PLANS | | | 1.FLOOR | | | 2.WALLS | | | 3.ROOF FRAMING | | | C.WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND | | | DESIGN WIND LOADS. | | | D.PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR | | | DOORS. >720 SQ. FT. | | | | | | | | | 2. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE | | | CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR, | | | MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHAPTER 1 VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2018-12-13 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2018-12-13 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2018-12-13 08:53:03 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY | | | PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.PLEASE PROVIDE GAZEBO INFORMATION FBC107 | | | | | | 1.FOR PRE-ENGINEERED GAZEBO: | | | A.PROVIDE FOUNDATION PLAN. | | | B.PROVIDE PRE-ENGINEERED DESIGN. | | | C.IDENTIFY TYPE OF TIE-DOWN TO FOUNDATION. | | | | | | | | | 2.FOR SITE BUILT GAZEBO: | | | A.PROVIDE FOUNDATION PLAN FOOTINGS/SLAB ON | | | GRADE/REINFORCING | | | B.PROVIDE BUILDING PLANS | | | 1.FLOOR | | | 2.WALLS | | | 3.ROOF FRAMING | | | C.WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND | | | DESIGN WIND LOADS. | | | D.PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR | | | DOORS. >720 SQ. FT. | | | | | | | | | 2. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE | | | CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR, | | | MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHAPTER 1 VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
5 |
Status |
P |
Date |
2019-02-14 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-02-14 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-02-14 |
Time |
11:03 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
F |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-01-29 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-01-29 |
Time |
16:00 |
Sent To |
PC |
|
| Notes |
| 2019-01-29 16:00:23 | THE PERMIT #18120237 HAS BEEN FAILED WITH THE FOLLOWING | | | REASON(S): | | | | | | 1. THE PROPOSED GAZEBO SHALL NOT NEED 6 FEET BUILDING | | | SEPARATION AS PREVIOUSLY MENTIONED. TO ENSURE | | | COMPLIANCE WITH SETBACKS, STAFF RECOMMENDS PLACING THE | | | PROPOSED GAZEBO RIGHT UP TO THE PRIMARY STRUCTURE. | | | 2. THE GAZEBO MUST MEET THE FOLLOWING SETBACK | | | REQUIREMENTS: | | | A. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | B. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | C. CORNER SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 | | | FEET. | | | 3. PLEASE ENSURE GAZEBO WIDTH, FRONT YARD SETBACK, AND | | | GAZEBO-PRIMARY STRUCTURE BUILDING SEPARATION TOTALS | | | 50.7 FEET AS ILLUSTRATE ON THE SUPPLIED SURVEY. | | | 4. THE PROVIDED PRIVACY WALL IS 12 FEET WIDE, WHILE THE | | | PROPOSED GAZEBO IS 20 FEET WIDE. PLEASE CLARIFY IF THIS | | | 12 FOOT WIDE PRIVACY WALL IS AN EXAMPLE OF WHAT IS TO | | | BE BUILT OR IS TO BE ACTUALLY PURCHASED. | | | 5. PLEASE PROVIDE GAZEBO SPECIFIC INFORMATION THAT | | | MATCHES THE SITE PLAN DIMENSIONS OF 19 FEET BY 20 FEET. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-01-14 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-01-14 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2019-01-14 08:41:37 | THE PERMIT #18120237 HAS BEEN FAILED WITH THE FOLLOWING | | | REASON(S): | | | | | | 1. THE PROPOSED GAZEBO SHALL NOT NEED 6 FEET BUILDING | | | SEPARATION AS PREVIOUSLY MENTIONED. TO ENSURE | | | COMPLIANCE WITH SETBACKS, STAFF RECOMMENDS PLACING THE | | | PROPOSED GAZEBO RIGHT UP TO THE PRIMARY STRUCTURE. | | | 2. PLEASE RECONCILE INCONSISTENT DIMENSIONS OF PROPOSED | | | GAZEBO ON APPLICATION DESCRIPTION AND SITE PLAN. | | | 3. THE GAZEBO MUST MEET THE FOLLOWING SETBACK | | | REQUIREMENTS: | | | A. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | B. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | C. SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 FEET. | | | 4. THE PROVIDED PRODUCT INFORMATION PROVIDES | | | INFORMATION REGARDING A PRIVACY WALL, NOT A GAZEBO. | | | PLEASE PROVIDE GAZEBO SPECIFIC INFORMATION. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2018-12-21 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2018-12-21 |
Time |
12:13 |
Sent To |
B |
|
| Notes |
| 2018-12-21 12:13:27 | THE PERMIT HAS FAILED, PLEASE ADDRESS THE FOLLOWING | | | COMMENTS: | | | 1. PROVIDE DIMENSIONS OF GAZEBO, BUILDING SEPARATION, | | | AND DISTANCE FROM PROPERTY LINES (SOUTH, WEST, AND | | | EAST) TO SCALE. | | | 2. PROVIDE A PHOTOGRAPH, SKETCH OR OTHER GRAPHIC FOR | | | THE APPERANCE OF THE GAZEBO. | | | 3. THE GAZEBO MUST MEET THE FOLLOWING REQUIREMENTS: | | | A. MINIMUM BUILDING SEPERATION OF 6 FEET (IF GAZEBO IS | | | ROOFED). | | | B. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | C. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | D. SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 FEET. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON | | | BORNGRABER AT [email protected] OR CALL 561-822-1428. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2018-12-13 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2018-12-11 |
Time |
11:50 |
Sent To |
PC |
|
| Notes |
| 2018-12-11 11:50:54 | THE PERMIT HAS FAILED, PLEASE ADDRESS THE FOLLOWING | | | COMMENTS: | | | 1. PROVIDE DIMENSIONS OF GAZEBO, BUILDING SEPARATION, | | | AND DISTANCE FROM PROPERTY LINES (SOUTH, WEST, AND | | | EAST) TO SCALE. | | | 2. PROVIDE A PHOTOGRAPH, SKETCH OR OTHER GRAPHIC FOR | | | THE APPERANCE OF THE GAZEBO. | | | 3. THE GAZEBO MUST MEET THE FOLLOWING REQUIREMENTS: | | | A. MINIMUM BUILDING SEPERATION OF 6 FEET (IF GAZEBO IS | | | ROOFED). | | | B. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | C. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | D. SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 FEET. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON | | | BORNGRABER AT [email protected] OR CALL 561-822-1428. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-15 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-12 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2019-02-13 11:27:04 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-01-31 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-31 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-23 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2019-01-24 16:49:16 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-14 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-09 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2019-01-10 12:45:19 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-02 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2018-12-19 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2018-12-20 11:42:32 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2018-12-13 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2018-12-07 |
Time |
11:04 |
Sent To |
HIST |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2019-02-14 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-02-14 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-02-14 |
Time |
11:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-01-29 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-01-29 |
Time |
15:59 |
Sent To |
B |
|
| Notes |
| 2019-01-29 15:59:54 | THE PERMIT #18120237 HAS BEEN FAILED WITH THE FOLLOWING | | | REASON(S): | | | | | | 1. THE PROPOSED GAZEBO SHALL NOT NEED 6 FEET BUILDING | | | SEPARATION AS PREVIOUSLY MENTIONED. TO ENSURE | | | COMPLIANCE WITH SETBACKS, STAFF RECOMMENDS PLACING THE | | | PROPOSED GAZEBO RIGHT UP TO THE PRIMARY STRUCTURE. | | | 2. THE GAZEBO MUST MEET THE FOLLOWING SETBACK | | | REQUIREMENTS: | | | A. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | B. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | C. CORNER SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 | | | FEET. | | | 3. PLEASE ENSURE GAZEBO WIDTH, FRONT YARD SETBACK, AND | | | GAZEBO-PRIMARY STRUCTURE BUILDING SEPARATION TOTALS | | | 50.7 FEET AS ILLUSTRATE ON THE SUPPLIED SURVEY. | | | 4. THE PROVIDED PRIVACY WALL IS 12 FEET WIDE, WHILE THE | | | PROPOSED GAZEBO IS 20 FEET WIDE. PLEASE CLARIFY IF THIS | | | 12 FOOT WIDE PRIVACY WALL IS AN EXAMPLE OF WHAT IS TO | | | BE BUILT OR IS TO BE ACTUALLY PURCHASED. | | | 5. PLEASE PROVIDE GAZEBO SPECIFIC INFORMATION THAT | | | MATCHES THE SITE PLAN DIMENSIONS OF 19 FEET BY 20 FEET. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-01-14 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-01-14 |
Time |
08:41 |
Sent To |
PC |
|
| Notes |
| 2019-01-14 08:42:09 | THE PERMIT #18120237 HAS BEEN FAILED WITH THE FOLLOWING | | | REASON(S): | | | | | | 1. THE PROPOSED GAZEBO SHALL NOT NEED 6 FEET BUILDING | | | SEPARATION AS PREVIOUSLY MENTIONED. TO ENSURE | | | COMPLIANCE WITH SETBACKS, STAFF RECOMMENDS PLACING THE | | | PROPOSED GAZEBO RIGHT UP TO THE PRIMARY STRUCTURE. | | | 2. PLEASE RECONCILE INCONSISTENT DIMENSIONS OF PROPOSED | | | GAZEBO ON APPLICATION DESCRIPTION AND SITE PLAN. | | | 3. THE GAZEBO MUST MEET THE FOLLOWING SETBACK | | | REQUIREMENTS: | | | A. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | B. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | C. SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 FEET. | | | 4. THE PROVIDED PRODUCT INFORMATION PROVIDES | | | INFORMATION REGARDING A PRIVACY WALL, NOT A GAZEBO. | | | PLEASE PROVIDE GAZEBO SPECIFIC INFORMATION. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2018-12-21 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2018-12-21 |
Time |
12:12 |
Sent To |
PC |
|
| Notes |
| 2018-12-21 12:13:06 | THE PERMIT HAS FAILED, PLEASE ADDRESS THE FOLLOWING | | | COMMENTS: | | | 1. PROVIDE DIMENSIONS OF GAZEBO, BUILDING SEPARATION, | | | AND DISTANCE FROM PROPERTY LINES (SOUTH, WEST, AND | | | EAST) TO SCALE. | | | 2. PROVIDE A PHOTOGRAPH, SKETCH OR OTHER GRAPHIC FOR | | | THE APPERANCE OF THE GAZEBO. | | | 3. THE GAZEBO MUST MEET THE FOLLOWING REQUIREMENTS: | | | A. MINIMUM BUILDING SEPERATION OF 6 FEET (IF GAZEBO IS | | | ROOFED). | | | B. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | C. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | D. SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 FEET. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON | | | BORNGRABER AT [email protected] OR CALL 561-822-1428. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2018-12-11 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2018-12-11 |
Time |
11:51 |
Sent To |
B |
|
| Notes |
| 2018-12-11 11:51:25 | THE PERMIT HAS FAILED, PLEASE ADDRESS THE FOLLOWING | | | COMMENTS: | | | 1. PROVIDE DIMENSIONS OF GAZEBO, BUILDING SEPARATION, | | | AND DISTANCE FROM PROPERTY LINES (SOUTH, WEST, AND | | | EAST) TO SCALE. | | | 2. PROVIDE A PHOTOGRAPH, SKETCH OR OTHER GRAPHIC FOR | | | THE APPERANCE OF THE GAZEBO. | | | 3. THE GAZEBO MUST MEET THE FOLLOWING REQUIREMENTS: | | | A. MINIMUM BUILDING SEPERATION OF 6 FEET (IF GAZEBO IS | | | ROOFED). | | | B. FRONT YARD SETBACK (SOUTH PROPERTY LINE) OF 25 FEET. | | | C. SIDE YARD SETBACK (EAST PROPERTY LINE) OF 5 FEET. | | | D. SIDE YARD SETBACK (WEST PROPERTY LINE) OF 10 FEET. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON | | | BORNGRABER AT [email protected] OR CALL 561-822-1428. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] |
|
|