Plan Review Details - Permit 18120043
| Plan Review Stops For Permit 18120043 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-01-28 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-28 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-28 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2019-01-28 14:38:27 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE DRAWINGS INDICATE THE DOORS ARE GOING TO BE | | | REMOVED. THE CHANGE TO THE FLOOR ELEVATION WILL AFFECT | | | THE REAR SLIDING DOOR AND ENTRANCE DOOR OPENINGS. | | | PLEASE INDICATE IF SAME DOORS ARE GOING TO BE | | | RE-INSTALLED OR NEW DOORS. IF SO PLEASE PROVIDE THE | | | PRODUCT APPROVALS. FBC 107 | | | | | | 2. IF THE DOOR OPENING DIMENSIONS ARE GOING TO CHANGE, | | | PLEASE PROVIDE THE STRUCTURAL DETAILS FOR THE WALL | | | CONSTRUCTION. FBC CHAPTER 6 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-08 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-08 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2018-12-08 12:58:26 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL / JOSEAN DUPREY | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6716 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. SINCE IT IS NOT CLEAR WHETHER OR NOT THE WORK DONE | | | WITHOUT PERMIT IN THE GARAGE CAN BE LEGALIZED, A PERMIT | | | TO RAISE THE FLOOR CANNOT BE ISSUED. NOTES STATE THAT | | | GARAGE WAS CONVERTED TO A KITCHEN. IMPACT FEE | | | ASSESSMENT IS REQUIRED, | | | | | | PLANS ARE NOT CLEAR AS TO SCOPE. IT SHOWS ITEMS AS | | | "EXISTING" BUT IF THIS WAS A GARAGE, IT APPEARS THAT | | | WALLS WERE CONSTRUCTED. IT IS ONLY "EXISTING" IF WORK | | | WAS DONE UNDER AN ISSUED PERMIT, INSPECTED, AND | | | FINALED. | | | | | | 2. PLANS ARE TO INCLUDE THE PRINTED NAME AND SIGNATURE | | | OF THE INDIVIDUAL TAKING RESPONSIBILITY FOR THE PLAN, | | | FBC 107. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-01-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-01-23 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-01-23 |
Time |
06:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-28 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-28 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2018-12-21 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2019-01-26 07:06:53 | 1/26 TO JD DESK | | | | | | | | 2018-12-26 15:21:16 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-12-14 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-12-03 |
Time |
14:04 |
Sent To |
PC |
|
| Notes |
| 2018-12-08 12:58:46 | 12/8 TO ZONING | | | | | 2018-12-04 14:04:16 | BLDG MISC 1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-01-25 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-01-25 |
Time |
05:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-01-08 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-01-08 |
Time |
10:59 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-12-14 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-12-14 |
Time |
09:47 |
Sent To |
PC |
|
| Notes |
| 2018-12-14 09:55:54 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) IF THE ORIGINAL GARAGE WAS REMOVED, THEN A PARKING | | | SPACE WAS ELIMINATED. PROVIDE A SURVEY ILLUSTRATING 2 | | | REQUIRED PARKING SPACES ONSITE. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. IF YOU WANT TO MEET IN PERSON TO GO OVER | | | THE ABOVE COMMENTS, PLEASE CALL OR E-MAIL ME TO | | | SCHEDULE AN APPOINTMENT. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] | | | |
|
|
|