Plan Review Details - Permit 18111143
| Plan Review Stops For Permit 18111143 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-19 |
Time |
09:56 |
Sent To |
M |
|
| Notes |
| 2019-03-19 10:00:49 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) INSTALL PER NFPA 30A, CODE FOR MOTOR FUEL DISPENSING | | | FACILITIES AND REPAIR GARAGES, 2015 EDITION | | | | | | CHAPTER 1 ADMINISTRATION | | | 1.1* SCOPE. | | | 1.1.1 SCOPE. THIS CODE SHALL APPLY TO MOTOR FUEL | | | DISPENSING | | | FACILITIES AND MOTOR FUEL DISPENSING AT FARMS AND | | | ISOLATED CONSTRUCTION | | | SITES. | | | | | | INCLUDING, BUT NOT LIMITED TO: | | | | | | CHAPTER 6 FUEL DISPENSING SYSTEMS | | | | | | 6.1 SCOPE. THIS CHAPTER SHALL APPLY TO THE SYSTEM AND | | | COMPONENTS | | | THAT DISPENSE FUEL INTO THE TANKS OF MOTOR VEHICLES AND | | | MARINE CRAFT. | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE IN ALL APPLICABLE | | | AREAS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-12-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-12-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-12-03 |
Time |
11:25 |
Sent To |
M |
|
| Notes |
| 2018-12-03 11:32:00 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) THERE ARE PLAN ATTACHED SHOWING LOCATION OR HOW | | | MANY. | | | | | | PLEASE PROVIDE A SITE PLAN INDICATING LOCATION AND | | | NUMBER. | | | | | | | | | | | | 2) THERE ARE SPECIFICATION SHEETS ATTACHED INDICATING | | | WHAT KIND AND LISTINGS. | | | | | | PLEASE PROVIDE MANUFACTURES SPECIFICATION SHEETS. | | | | | | | | | | | | 3) THERE ARE NO INDICATIONS OF COMPLIANCE WITH ANY FIRE | | | CODES. | | | | | | ALL INSTALLTION SHALL COMPLY WITH ALL LOCAL AND | | | NATIONAL CODES INDCULEING, BUT NOT LIMITED TO, | | | | | | FLAMMABLE AND COMBUSTIBLE LIQUIDS SHALL COMPLY WITH | | | NFPA 30, 2015 EDITION | | | MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES | | | SHALL COMPLY WITH NFPA 30 A, 2015 EDITION | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE TO THE RE-SUBMITTED | | | PLAN SETS. | | | | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5)ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-04-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-14 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-03-15 13:30:15 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-12-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-11-28 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2018-11-29 13:50:44 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-04-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-08 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-08 |
Time |
10:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-19 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-19 |
Time |
16:21 |
Sent To |
I |
|
| Notes |
| 2018-12-19 16:32:34 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #1811143 | | | 12/18/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COMPLETE PLANS AND SPECIFICATIONS COVERING | | | THE COMPLETE SCOPE OF WORK FOR REPLACEMENT OF THE | | | DISPENSERS. | | | | | | 2) THE TOTAL VALUE LISTED ON THE APPLICATION MUST BE | | | VERIFIED- PLEASE PROVIDE A COPY OF THE SIGNED CONTRACT. | | | PLEASE NOTE THAT THE VALUE SHALL INCLUDE LABOR, | | | MATERIALS, EQUIPMENT, SITE WORK, AND DESIGN FEES- | | | SECTION 109.3 WPB. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|