Plan Review Details - Permit 18111082
Plan Review Stops For Permit 18111082
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-12-08 Cont ID  
Sent By rmcdouga Date 2018-12-08 Time 18:44 Rev Time 0.00
Received By shill Date 2018-12-08 Time 18:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-12-11 Cont ID  
Sent By jpearson Date 2018-12-11 Time 08:51 Rev Time 0.00
Received By jpearson Date 2018-12-11 Time 07:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-12-06 Cont ID  
Sent By scaldero Date 2018-12-06 Time 10:59 Rev Time 0.00
Received By scaldero Date 2018-12-06 Time 10:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-10 Cont ID  
Sent By jesmith Date 2019-01-10 Time 13:29 Rev Time 0.00
Received By jesmith Date 2019-01-10 Time 13:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-02 Cont ID  
Sent By jesmith Date 2019-01-02 Time 15:10 Rev Time 0.00
Received By jesmith Date 2019-01-02 Time 15:10 Sent To  
Notes
2018-11-29 11:47:39B25

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-01-10 Cont ID  
Sent By jesmith Date 2019-01-10 Time 13:28 Rev Time 0.00
Received By jesmith Date 2019-01-10 Time 13:26 Sent To  
Notes
2019-01-10 13:28:09CODES IN EFFECT:
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 5TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 2ND REVIEW: DENIED
 PLUMBING COMMENTS
 PER FBC PL TABLE 403.1, A DRINKING FOUNTAIN AND SERVICE
 SINK IS REQUIRED BASED UPON FBC TABLE 1004.1.2 FOR
 GROUP B BUSINESS GROSS 100'; 1800 SQ FT/100=18
 OCCUPANTS
 IT HAS BEEN DETERMINED BY THE BUILDING OFFICIAL THAT
 REGARDLESS OF THE NUMBER OF EMPLOYEES AND POSSIBLE
 CUSTOMERS THAT MIGHT BE OCCUPYING THE SPACE AT ANY
 GIVEN TIME, THE OCCUPANCY LOAD IS STILL 18 PERSONS. BY
 NOT REQUIRING THE DRINKING FOUNTAIN AND SERVICE SINK,
 THE NEXT TENANT WOULD BE DEEMED OUT OF COMPLIANCE
 PLACING AN UNFAIR BURDEN ON THAT TENANT.
 THE OCCUPANCY LOAD COULD BE LOWERED BY CONVERTING A
 PORTION OF THE SPACE TO STORAGE WHICH HAS AN OCCUPANT
 LOAD FACTOR OF 300 GROSS. YOU WOULD HAVE TO REDUCE THE
 GROUP B AREA TO 1300 SQ. FT. TO ALLOW AN OCCUPANT LOAD
 OF 13 + 2 FOR 500 SQ. FT. OF STORAGE TO EQUAL 15. THIS
 WOULD HAVE TO BE REFLECTED ON RESUBMITTED SIGNED AND
 SEALED PLANS IN PER WPB FBC 107.2.1.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-01-02 Cont ID  
Sent By gjohnson Date 2019-01-02 Time 15:10 Rev Time 0.00
Received By jesmith Date 2019-01-02 Time 14:57 Sent To  
Notes
2019-01-02 15:10:14CODES IN EFFECT:
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 5TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 2ND REVIEW: DENIED
 PLUMBING COMMENTS
 1. PER FBC PL TABLE 403.1, A DRINKING FOUNTAIN AND
 SERVICE SINK IS REQUIRED BASED UPON FBC TABLE 1004.1.2
 FOR GROUP B BUSINESS GROSS 100'; 1800 SQ FT/100=18
 OCCUPANTS
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved