| Plan Review Stops For Permit 18111031 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-11 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-11 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2019-03-11 10:39:23 | ***PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PRODUCT APPROVALS FOR LOUVERS, METAL ROOF ARE TO BE | | | SUBMITTED PRIOR TO INSTALLATION. IT APPEARS THAT A | | | PARTIAL APPROVAL WAS PROVIDED BUT THE FLORIDA STATE | | | PRODUCT APPROVAL NUMBER IS NOT ON THE DOCUMENTS | | | SUBMITTED. | | | | | | 2. A SEPARATE ROOF PERMIT IS REQUIRED. ROOFING | | | CONTRACTOR IS TO INDICATE OPTIONS PROPOSED TO SHOW | | | COMPLIANCE WITH DESIGN PRESSURES SPECIFIED ON SHEET S1. | | | OR, THIS INFORMATION CAN BE PROVIDED AT THIS TIME. | | | | | | 3. TRUSS ENGINEERING REVIEWED BY ENGINEER OF RECORD IS | | | TO BE PROVIDED ON THE JOB PRIOR TO INSPECTION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-02-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-16 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-16 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2019-02-16 11:28:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | | FOR COMPONENTS AND CLADDING. THIS CAN BE A PROVISO ITEM | | | FOR LARGE PROJECTS, BUT IT APPEARS THAT ROOFING AND THE | | | LOUVER ARE A SIGNIFICANT PART OF THIS PROJECT. PROVIDE | | | AT THIS TIME, REVIEWED BY DESIGNER OF RECORD, OR | | | PROVIDE RATIONALE FOR REQUESTING A PROVISO, FBC B 1609. | | | | | | 2ND REVIEW - THE PRODUCT APPROVALS SUBMITTED ARE | | | INCOMPLETE. THEY LACK AT LEAST ONE OF THE FOLLOWING: | | | THE FLORIDA STATE PRODUCT APPROVAL COVER PAGE, | | | EVALUATION REPORT, INSTALLATION INSTRUCTIONS. | | | | | | 2. OK | | | | | | 3. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A SEPARATE ROOF PERMIT IS REQUIRED. ROOFING CONTRACTOR | | | IS TO INDICATE OPTIONS PROPOSED TO SHOW COMPLIANCE WITH | | | DESIGN PRESSURES SPECIFIED ON SHEET S1. OR, THIS | | | INFORMATION CAN BE PROVIDED AT THIS TIME. | | | | | | TRUSS ENGINEERING REVIEWED BY ENGINEER OF RECORD IS TO | | | BE PROVIDED ON THE JOB PRIOR TO INSPECTION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-05 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-05 |
Time |
11:07 |
Sent To |
M |
|
| Notes |
| 2018-12-05 11:21:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | | FOR COMPONENTS AND CLADDING. THIS CAN BE A PROVISO ITEM | | | FOR LARGE PROJECTS, BUT IT APPEARS THAT ROOFING AND THE | | | LOUVER ARE A SIGNIFICANT PART OF THIS PROJECT. PROVIDE | | | AT THIS TIME, REVIEWED BY DESIGNER OF RECORD, OR | | | PROVIDE RATIONALE FOR REQUESTING A PROVISO, FBC B 1609. | | | | | | 2. S1, LOUVER OPENING DETAIL, THE DETAIL DOES NOT | | | GRAPHICALLY SHOW REBAR ON SIDES OR BELOW THE PROPOSED | | | NEW OPENING. EMBEDMENT INTO EXISTING IS NOT SPECIFIED. | | | NOTE STATES TO VERIFY FILLED CELLS IN FIELD; IT APPEARS | | | THAT AT LEAST ONE SIDE WILL BE REQUIRED TO BE | | | CONSTRUCTED AS WELL AS THE SILL, UNLESS ENGINEER HAS | | | KNOWLEDGE OF EXISTING CONDITIONS, PLEASE PROVIDE | | | COMPLETE DETAILS OR CLARIFY. | | | | | | 2. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A SEPARATE ROOF PERMIT IS REQUIRED. ROOFING CONTRACTOR | | | IS TO INDICATE OPTIONS PROPOSED TO SHOW COMPLIANCE WITH | | | DESIGN PRESSURES SPECIFIED ON SHEET S1. OR, THIS | | | INFORMATION CAN BE PROVIDED AT THIS TIME. | | | | | | TRUSS ENGINEERING REVIEWED BY ENGINEER OF RECORD IS TO | | | BE PROVIDED ON THE JOB PRIOR TO INSPECTION. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-05 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-03-05 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-05 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-05 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-10 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-10 |
Time |
18:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-11 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-21 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-16 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-01-17 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-11 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-11-26 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2018-11-28 13:35:55 | BLDG MISC 1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-03-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-06 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-06 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-01-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-01-31 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-01-31 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-01-31 16:44:40 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18111031 | | | 1/31/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IN RESPONSE TO THE 1ST REVIEW COMMENTS, THE | | | ARCHITECT HAS SUBMITTED AN OLD PLAN FOR THE EXISTING | | | FACILTIY THAT IS DATED AUGUST 2000. THERE ARE NO CITY | | | STAMPS ON THE PLAN, NO ADDRESS SHOWN, AND NO COPY OF | | | THIS PLAN IN OUR CITY RECORDS TO VALIDATE IT. THE | | | CORRECTED NEW PLAN FOR THE FACILITY IS NOW SHOWING | | | THREE NEW FANS INSTEAD OF ONE. PLEASE REVISE THE NEW | | | PLAN TO ADDRESS COMMENTS #2- 5 BELOW. | | | | | | 2) SHEET ME-1: PROVIDE SIZING CALCULATION FOR THE NEW | | | EXHAUST FANS BASED ON TABLE 403.3.1.1 FBC M. | | | | | | 3) ME-1: INDICATE THE SEQUENCE OF OPERATION FOR THE | | | FANS. WILL THE FAN RUN CONTINUOUSLY OR INTERMITTENTLY? | | | | | | 4) ME-1: INDICATE HOW MAKEUP AIR IS TO BE PROVIDED FOR | | | THE EXHAUST. | | | | | | 5) ME-1: SUBMIT A FL. PRODUCT APPROVAL OR MIAMI-DADE | | | NOA FOR THE NEW LOUVERS- RULE 9N-3 FAC. | | | | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-10 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-10 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2018-12-10 17:00:30 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18111031 | | | 12/10/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET ME-1: PROVIDE A SIZING CALCULATION FOR THE NEW | | | EXHAUST FAN BASED ON TABLE 403.3.1.1 FBC M. | | | | | | 2) ME-1: INDICATE THE SEQUENCE OF OPERATION FOR THE | | | FAN. WILL THE FAN RUN CONTINUOUSLY OR INTERMITTENTLY? | | | THE NOTES ON THE PLAN SHOW "EXISTING OPERATING | | | CONTROLS" BUT THIS IS A "NEW" FAN. ARE THERE GAS | | | SENSORS LOCATED IN THE GARAGE? PLEASE SEE SECTION 405.1 | | | AND PROVIDE MORE INFORMATION. | | | | | | 3) ME-1: SUBMIT A FL. PRODUCT APPROVAL OR MIAMI-DADE | | | NOA FOR THE NEW LOUVER- RULE 9N-3 FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2019-02-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-16 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-16 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2019-02-16 11:27:09 | PROVISO: ROOF PRODUCT APPROVAL REVIEWED BY DESIGNER OF | | | RECORD ARE TO BE SUBMITTED WITH ROOF PERMIT APPLICATION | | | PRIOR TO INSTALLATION. | | | | | | |
|
|