| 2018-11-16 17:30:24 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS | | | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL1654-R22 | | | SUBMITTED: | | | THE MAXIMUM DESIGN PRESSURES FOR BONDED INSULATED | | | SELECTED ASSEMBLY W-1 ON PAGE 5 OF 58 ARE -52.5PSF. | | | BONDED ASSEMBLIES DON'T ALLOW RATIONAL ANALYSIS TO | | | INCREASE THE DESIGN PRESSURES. SEE NOTE #10 ON PAGE 2 | | | OF 58. THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES AS REQUIRED BY SEC. R301.1 | | | FBC-RESIDENTIAL. THEREFORE, THIS ASSEMBLY CAN NOT BE | | | USED. NEED TO PROVIDE ANOTHER PRODUCT APPROVAL FOR | | | ASSEMBLY THAT MEETS OR EXCEEDS THE DESIGN PRESSURES FOR | | | ALL ROOF ZONES. | | | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION ($1500) | | | FOR THE ADDITIONAL WORK SEEMS TO BE LOW FOR A FLAT ROOF | | | WITH INSULATION. SEC. 109.3 CITY AMENDMENTS. SPECIFY | | | HOW MUCH FLAT ROOF AREA IS GOING TO BE RE-ROOFED. | | | VALUATION WILL BE ADJUSTED ACCORDINGLY. OR PROVIDE COPY | | | OF SIGNED CONTRACT FOR BUILDING OFFICIAL | | | REVIEW/APPROVAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-12-28 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-12-28 |
Time |
16:12 |
Sent To |
I |
|
| Notes |
| 2018-12-28 16:12:22 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-11-16 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-11-15 |
Time |
16:16 |
Sent To |
I |
|
| Notes |
| 2018-11-15 16:16:30 | REVISION ROUTED TO JGOMEZ |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |