Plan Review Details - Permit 18110678
| Plan Review Stops For Permit 18110678 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-14 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-12 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-12-18 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-12-18 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2018-12-18 16:58:04 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC 107. PLEASE REVIEW AND PROVIDE MORE INFORMATION: | | | | | | 1. PAGE A-1 DESIGN STATEMENT SHOWS 140 MPH, THE CURRENT | | | CODE IS FORE 170 MPH. | | | 2. PAGE A-1 CODE DATA SHOWS TYPE II-B, THIS TYPE OF | | | STRUCTURE APPEARS TO BE TYPE V-B. | | | 3. THE SIGNED AND SEALED PLANS ARE NOT CORRECT. PLEASE | | | PROVIDE THE CORRECT DIGITAL SIGNATURE AND SEAL. | | | 4. THERE HAVE BEEN NO SUB-PERMITS APPLIED FOR ? | | | 5. PLEASE PROVIDE THE REQUIRED PRODUCT APPROVALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-05 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-05 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-14 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-03 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-12-18 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-11-16 |
Time |
08:08 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-12-10 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-12-10 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2018-12-10 09:06:34 | WINDOW A/C UNITS PER PLANS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-14 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-14 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-12-18 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-12-18 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |