| Plan Review Stops For Permit 18110671 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-07-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-16 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-16 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-26 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-26 |
Time |
17:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-08 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-08 |
Time |
17:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-05 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-05 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
bwoods |
Date |
2019-04-17 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
bwoods |
Date |
2019-04-17 |
Time |
00:00 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
Bwoods |
Date |
2018-11-30 |
Time |
00:00 |
Rev Time |
|
| Received By |
|
Date |
2018-11-30 |
Time |
00:00 |
Sent To |
M |
|
| Notes |
| 2018-11-30 15:14:23 | CONFLICT OF DOOR SCHEDULE & WALL LEGEND ON PAGE A1 - | | | NEW CONSTRUCTION - SHELL | | | EX.1 - THERE ARE ONLY TWO EXISTING DOORS FOR UNIT 103 | | | WHICH ARE 1 & 2 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-07-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-16 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-09 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2019-07-10 15:59:21 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-02 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-01 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2019-05-02 13:06:30 | RESUB ROUTED TO THUNT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-30 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-26 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2019-04-29 15:07:40 | RESUB ROUTED TO THUNT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-04-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-04-19 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-03-22 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-27 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-11-15 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2018-11-19 14:16:18 | B08 | | 2018-11-16 09:52:40 | LIBRARY |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-11 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-10 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-13 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-13 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2018-12-13 12:05:38 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18110671 | | | 12/14/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-2: AN ENERGY RECOVERY VENTILATOR IS REQUIRED | | | FOR THE NAIL SALON EXHAUST SYSTEM IN COMPLIANCE WITH | | | SECTION C403.2.7 FBC EC. PLEASE CORRECT THE PLANS AND | | | CALCULATIONS ACCORDINGLY. | | | | | | 2) M-2: REFER TO TABLE 403.3.1.1 AND FOOTNOTE H UNDER | | | THE TABLE AND PROVIDE AN EXHAUST VENTILATION | | | CALCULATION FOR THE PROPOSED SPACE AT THE REQUIRED RATE | | | OF 0.60 CFMS PER SF. PLEASE NOTE THE FOLLOWING: A) THE | | | CURRENT EXHAUST SYSTEM INDICATED AT 1000 CFRMS DOES NOT | | | MEET THE REQUIRED 0.60 CFMS PER SF RATE REQUIRED RATE | | | SO ADDITIONAL EXHAUST MUST BE PROVIDED. B) IT IS | | | REQUIRED THAT THE EXHAUST SYSTEM RUN CONTINOULSY DURING | | | OCCUPANCY HOWEVER THE SEQUENCE OF OPERATION FOR THE | | | SYSTEM HAS NOT BEEN ADDRESSED ON THE PLANS- SEE SECTION | | | 501.4 FBC M. PLEASE NOTE THAT INSTALLATION OF THE ERV | | | MAY RESOLVE THIS ISSUE BECAUSE IT WILL HAVE TO BE | | | CONNECTED TO THE AC SYSTEM. | | | | | | 3) M-1, M-2: BASED ON THE NUMBER OF PEDICURE CHAIRS, IT | | | APPEARS THAT THE 38 PERSON OCCUPANT LOAD WHICH IS SHOWN | | | ON THE LIFE SAFETY PLANS AND THE O/A TABLE IS | | | INCORRECT. PEDICURE CHAIRS WERE COUNTED AS ONE | | | OCCUPANT, HOWEVER THE CHEMICAL APPLICATOR AT EACH CHAIR | | | WAS NOT COUNTED. | | | | | | 4) M-1: REFER TO TABLE 403.3.1.1 FOOTNOTE B: THE PLAN | | | SHOWS RECIRCULATION OF AIR FROM THE SALON TO THE | | | BREAKROOM, FACIAL ROOM, AND THE TOILET ROOMS WHICH IS | | | PROHIBITED. | | | | | | 5) M-2: CLARIFY HOW THE SOURCE CAPTURE SYSTEM FOR THE | | | PEDICURE CHAIRS WILL BE IN COMPLIANCE WITH SECTION | | | 502.20 WHICH REQUIRES THE EXHAUST INLET TO BE LOCATED | | | NOT MORE THAN 12 INCHES HORIZONTALLY AND VERTICALLY | | | FROM THE POINT OF CHEMICAL APPLICATION. THE CURRENT | | | PLAN AND DETAILS INDICATE THE INLETS ON THE FLOOR UNDER | | | THE CHAIRS. | | | | | | 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE DRYER | | | PER SECTION 504.1 FBC M. A) INDICATE THE TOTAL RUN | | | LENGTH OF THE DRYER VENT- SECTION 504.8.4. B) PLEASE | | | NOTE THAT MAKEUP AIR MAY BE REQUIRED- SECTION 504.6. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2019-07-11 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-07-11 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-07-11 |
Time |
06:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-02 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-02 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2019-05-02 14:20:30 | PLUMBING 4TH REVIEW**DENIED**FL ST 553.80 (B)2B WITH | | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | 1) ANSWERED | | | | | | 2) 3RD REQUEST .PROVIDE CLEAR FLOOR SPACE ON SHT. A-1 | | | FOR 1 OF THE 2 LOBBY HAND SINKS, . FBC-A 212.2, 606 | | | | | | 3) 3RD REQUEST .PROVIDE CLEAR FLOOR SPACE FOR THE | | | DRINKING FOUNTAIN ON SHT. A-1 FBC 107.3.5 | | | | | | 4) 3RD REQUEST. PROVIDE INSTALLATION MANUAL FOR THE | | | LINT INTERCEPTOR. FBC 107.2.1 | | | | | | 5) ANSWERED | | | | | | 6) ANSWERED | | | | | | 7) 3RD REQUEST. NO RESPONSE PROVIDED NO INSTALLATION | | | MANUALS PROVIDED. PROVIDE PEDICURE CHAIRS SPEC SHEETS | | | AND INSTALLATION MANUAL'S. FBC 107.3.5 | | | | | | 8) 2ND REQUEST. SHT P-1 IIS NOW SEALED BUT STILL NOT | | | SIGNED . FAC 61G15-23.001 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-30 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-30 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2019-04-29 17:57:38 | PLUMBING 3RD REVIEW**DENIED** | | | | | | 1) ANSWERED | | | | | | 2) 2ND REQUEST PARTIAL ANSWER.PROVIDE CLEAR FLOOR SPACE | | | ON SHT. A-1 FOR 1 OF THE 2 LOBBY HAND SINKS, . FBC-A | | | 212.2, 606 | | | | | | 3) 2ND REQUEST PARTIAL ANSWER.PROVIDE CLEAR FLOOR SPACE | | | FOR THE DRINKING FOUNTAIN ON SHT. A-1 FBC 107.3.5 | | | | | | 4) PARTIAL ANSWERED. PROVIDE INSTALLATION MANUAL FOR | | | THE LINT INTERCEPTOR. FBC 107.2.1 | | | | | | 5) 2ND REQUEST PARTIAL ANSWER. ALL NOTES ARE NOW | | | MISSING. SHOW THE RELIEF LINE FOR THE WATER HEATER | | | DISCHARGING INTO THE ROOM/ HEATER PAN/ PIPE SIZING. | | | FBC-P 504.6. PROVIDE HOW THE PAN DRAIN IS GOING TO BE | | | RAN OUTSIDE AND TERMINATE MIN 6" ABOVE GRADE. FBC-P | | | 504.7, 504.7.1, 504.7.2 | | | | | | 6) ANSWERED BUT ALL PIPE SIZING IS MISSING FOR BOTH | | | SANITARY AND WATER ISOMETRIC. FBC 107.3.5 | | | | | | 7) 2ND REQUEST. NO RESPONSE PROVIDED NO INSTALLATION | | | MANUALS PROVIDED. PROVIDE PEDICURE CHAIRS SPEC SHEETS | | | AND INSTALLATION MANUAL'S. FBC 107.3.5 | | | | | | | | | NEW COMMENT: | | | | | | 1) SHT P-1 IS NOT SIGNED AND SEALED. SHT P-2 IS NOT | | | SEALED . FAC 61G15-23.001 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-04-08 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-08 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-08 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2019-04-08 15:20:57 | PLUMBING 2ND REVIEW**DENIED** | | | | | | 1) BEING THAT THIS IS A CHANGE OF OCCUPANCY BOTH THE | | | EXISTING RESTRROOMS SHALL COMPLY WITH 2017 FBC PLUMBING | | | AND ACCESSIBILITY. THE RESTROOMS MUST FULLY COMPLY AND | | | BE PART OF THE INSPECTIONS. FBC 107.3.5 | | | | | | 2) PROVIDE CLEAR FLOOR SPACE AND CABINET HEIGHT FOR 1 | | | OF THE 2 HAND SINKS. FBC-A 212.2, 606 | | | | | | 3) SHT P-1 CALLS OUT THE DRINKING FOUNTAIN IS EXISTING. | | | PERMIT # 17060769 AND FINAL REVISION #18019865 DO NOT | | | SHOW A DRINKING FOUNTAIN, PROVIDE CLEAR FLOOR SPACE AND | | | MOUNTING HEIGHT DETAILS. FBC 107.3.5 | | | | | | 4) SHT P-1 LITE FILTER DOES NOT MEET THE INTENT OF THE | | | CODE FBC-P 1003.1. PROVIDE A LIT INTERCEPTOR AND THE | | | COMPLETE INSTALLATION MANUAL. FBC -P 1003.6. | | | | | | 5) SHOW THE RELIEF LINE FOR THE WATER HEATER | | | DISCHARGING INTO THE ROOM/ HEATER PAN. FBC-P 504.6. | | | PROVIDE HOW THE PAN DRAIN IS GOING TO BE RAN OUTSIDE | | | AND TERMINATE MIN 6" ABOVE GRADE. FBC-P 504.7, 504.7.1, | | | 504.7.2 | | | | | | 6) PLUMBING ISOMETRIC AND FLAT DRAWING DOERS NOT SHOW | | | EITHER GROUP OF PEDICURE CHAIRS AS VENTED. PROVIDE | | | ISOMETRIC AND FLAT DRAWING PROPERLY VENTED ALL FIXTURES | | | FBC-P 901.2.1. | | | | | | 7) PROVIDE PEDICURE CHARIS SPEC SHEETS AND INSTALLATION | | | MANUAL'S. FBC 107.3.5 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-12-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-27 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-27 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-12-21 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-12-21 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|