Plan Review Details - Permit 18110671
Plan Review Stops For Permit 18110671
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-07-16 Cont ID  
Sent By shill Date 2019-07-16 Time 08:42 Rev Time 0.00
Received By shill Date 2019-07-16 Time 08:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-03-26 Cont ID  
Sent By shill Date 2019-03-26 Time 17:10 Rev Time 0.00
Received By shill Date 2019-03-26 Time 17:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-12-08 Cont ID  
Sent By shill Date 2018-12-08 Time 17:57 Rev Time 0.00
Received By shill Date 2018-12-08 Time 17:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-12-05 Cont ID  
Sent By jpearson Date 2018-12-05 Time 13:34 Rev Time 0.00
Received By jpearson Date 2018-12-05 Time 10:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-04-17 Cont ID  
Sent By bwoods Date 2019-04-17 Time 00:00 Rev Time 0.00
Received By bwoods Date 2019-04-17 Time 00:00 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date   Cont ID  
Sent By Bwoods Date 2018-11-30 Time 00:00 Rev Time  
Received By   Date 2018-11-30 Time 00:00 Sent To M
Notes
2018-11-30 15:14:23CONFLICT OF DOOR SCHEDULE & WALL LEGEND ON PAGE A1 -
 NEW CONSTRUCTION - SHELL
 EX.1 - THERE ARE ONLY TWO EXISTING DOORS FOR UNIT 103
 WHICH ARE 1 & 2
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2019-07-16 Cont ID  
Sent By shill Date 2019-07-16 Time 08:42 Rev Time 0.00
Received By shill Date 2019-07-09 Time 15:59 Sent To  
Notes
2019-07-10 15:59:21RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-05-02 Cont ID  
Sent By thunt Date 2019-05-02 Time 14:20 Rev Time 0.00
Received By thunt Date 2019-05-01 Time 13:06 Sent To  
Notes
2019-05-02 13:06:30RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-04-30 Cont ID  
Sent By thunt Date 2019-04-30 Time 06:51 Rev Time 0.00
Received By thunt Date 2019-04-26 Time 15:07 Sent To  
Notes
2019-04-29 15:07:40RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-04-19 Cont ID  
Sent By cpuell Date 2019-04-19 Time 13:05 Rev Time 0.00
Received By cpuell Date 2019-03-22 Time 15:26 Sent To  
Notes
2019-03-25 15:26:58B18

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-27 Cont ID  
Sent By gjohnson Date 2018-12-27 Time 10:06 Rev Time 0.00
Received By gjohnson Date 2018-11-15 Time 09:52 Sent To  
Notes
2018-11-19 14:16:18B08
2018-11-16 09:52:40LIBRARY

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-04-11 Cont ID  
Sent By ccole Date 2019-04-11 Time 08:17 Rev Time 0.00
Received By ccole Date 2019-04-10 Time 17:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-12-13 Cont ID  
Sent By ccole Date 2018-12-13 Time 11:13 Rev Time 0.00
Received By ccole Date 2018-12-13 Time 10:58 Sent To  
Notes
2018-12-13 12:05:381ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18110671
 12/14/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-2: AN ENERGY RECOVERY VENTILATOR IS REQUIRED
 FOR THE NAIL SALON EXHAUST SYSTEM IN COMPLIANCE WITH
 SECTION C403.2.7 FBC EC. PLEASE CORRECT THE PLANS AND
 CALCULATIONS ACCORDINGLY.
  
 2) M-2: REFER TO TABLE 403.3.1.1 AND FOOTNOTE H UNDER
 THE TABLE AND PROVIDE AN EXHAUST VENTILATION
 CALCULATION FOR THE PROPOSED SPACE AT THE REQUIRED RATE
 OF 0.60 CFMS PER SF. PLEASE NOTE THE FOLLOWING: A) THE
 CURRENT EXHAUST SYSTEM INDICATED AT 1000 CFRMS DOES NOT
 MEET THE REQUIRED 0.60 CFMS PER SF RATE REQUIRED RATE
 SO ADDITIONAL EXHAUST MUST BE PROVIDED. B) IT IS
 REQUIRED THAT THE EXHAUST SYSTEM RUN CONTINOULSY DURING
 OCCUPANCY HOWEVER THE SEQUENCE OF OPERATION FOR THE
 SYSTEM HAS NOT BEEN ADDRESSED ON THE PLANS- SEE SECTION
 501.4 FBC M. PLEASE NOTE THAT INSTALLATION OF THE ERV
 MAY RESOLVE THIS ISSUE BECAUSE IT WILL HAVE TO BE
 CONNECTED TO THE AC SYSTEM.
  
 3) M-1, M-2: BASED ON THE NUMBER OF PEDICURE CHAIRS, IT
 APPEARS THAT THE 38 PERSON OCCUPANT LOAD WHICH IS SHOWN
 ON THE LIFE SAFETY PLANS AND THE O/A TABLE IS
 INCORRECT. PEDICURE CHAIRS WERE COUNTED AS ONE
 OCCUPANT, HOWEVER THE CHEMICAL APPLICATOR AT EACH CHAIR
 WAS NOT COUNTED.
  
 4) M-1: REFER TO TABLE 403.3.1.1 FOOTNOTE B: THE PLAN
 SHOWS RECIRCULATION OF AIR FROM THE SALON TO THE
 BREAKROOM, FACIAL ROOM, AND THE TOILET ROOMS WHICH IS
 PROHIBITED.
  
 5) M-2: CLARIFY HOW THE SOURCE CAPTURE SYSTEM FOR THE
 PEDICURE CHAIRS WILL BE IN COMPLIANCE WITH SECTION
 502.20 WHICH REQUIRES THE EXHAUST INLET TO BE LOCATED
 NOT MORE THAN 12 INCHES HORIZONTALLY AND VERTICALLY
 FROM THE POINT OF CHEMICAL APPLICATION. THE CURRENT
 PLAN AND DETAILS INDICATE THE INLETS ON THE FLOOR UNDER
 THE CHAIRS.
  
 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE DRYER
 PER SECTION 504.1 FBC M. A) INDICATE THE TOTAL RUN
 LENGTH OF THE DRYER VENT- SECTION 504.8.4. B) PLEASE
 NOTE THAT MAKEUP AIR MAY BE REQUIRED- SECTION 504.6.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2019-07-11 Cont ID  
Sent By tklarge Date 2019-07-11 Time 08:19 Rev Time 0.00
Received By tklarge Date 2019-07-11 Time 06:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2019-05-02 Cont ID  
Sent By thunt Date 2019-05-02 Time 14:20 Rev Time 0.00
Received By thunt Date 2019-05-02 Time 14:20 Sent To  
Notes
2019-05-02 14:20:30PLUMBING 4TH REVIEW**DENIED**FL ST 553.80 (B)2B WITH
 RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
 1) ANSWERED
  
 2) 3RD REQUEST .PROVIDE CLEAR FLOOR SPACE ON SHT. A-1
 FOR 1 OF THE 2 LOBBY HAND SINKS, . FBC-A 212.2, 606
  
 3) 3RD REQUEST .PROVIDE CLEAR FLOOR SPACE FOR THE
 DRINKING FOUNTAIN ON SHT. A-1 FBC 107.3.5
  
 4) 3RD REQUEST. PROVIDE INSTALLATION MANUAL FOR THE
 LINT INTERCEPTOR. FBC 107.2.1
  
 5) ANSWERED
  
 6) ANSWERED
  
 7) 3RD REQUEST. NO RESPONSE PROVIDED NO INSTALLATION
 MANUALS PROVIDED. PROVIDE PEDICURE CHAIRS SPEC SHEETS
 AND INSTALLATION MANUAL'S. FBC 107.3.5
  
 8) 2ND REQUEST. SHT P-1 IIS NOW SEALED BUT STILL NOT
 SIGNED . FAC 61G15-23.001
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status F Date 2019-04-30 Cont ID  
Sent By thunt Date 2019-04-30 Time 06:51 Rev Time 0.00
Received By thunt Date 2019-04-30 Time 06:50 Sent To  
Notes
2019-04-29 17:57:38PLUMBING 3RD REVIEW**DENIED**
  
 1) ANSWERED
  
 2) 2ND REQUEST PARTIAL ANSWER.PROVIDE CLEAR FLOOR SPACE
 ON SHT. A-1 FOR 1 OF THE 2 LOBBY HAND SINKS, . FBC-A
 212.2, 606
  
 3) 2ND REQUEST PARTIAL ANSWER.PROVIDE CLEAR FLOOR SPACE
 FOR THE DRINKING FOUNTAIN ON SHT. A-1 FBC 107.3.5
  
 4) PARTIAL ANSWERED. PROVIDE INSTALLATION MANUAL FOR
 THE LINT INTERCEPTOR. FBC 107.2.1
  
 5) 2ND REQUEST PARTIAL ANSWER. ALL NOTES ARE NOW
 MISSING. SHOW THE RELIEF LINE FOR THE WATER HEATER
 DISCHARGING INTO THE ROOM/ HEATER PAN/ PIPE SIZING.
 FBC-P 504.6. PROVIDE HOW THE PAN DRAIN IS GOING TO BE
 RAN OUTSIDE AND TERMINATE MIN 6" ABOVE GRADE. FBC-P
 504.7, 504.7.1, 504.7.2
  
 6) ANSWERED BUT ALL PIPE SIZING IS MISSING FOR BOTH
 SANITARY AND WATER ISOMETRIC. FBC 107.3.5
  
 7) 2ND REQUEST. NO RESPONSE PROVIDED NO INSTALLATION
 MANUALS PROVIDED. PROVIDE PEDICURE CHAIRS SPEC SHEETS
 AND INSTALLATION MANUAL'S. FBC 107.3.5
  
  
 NEW COMMENT:
  
 1) SHT P-1 IS NOT SIGNED AND SEALED. SHT P-2 IS NOT
 SEALED . FAC 61G15-23.001
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-04-08 Cont ID  
Sent By thunt Date 2019-04-08 Time 15:21 Rev Time 0.00
Received By thunt Date 2019-04-08 Time 14:17 Sent To  
Notes
2019-04-08 15:20:57PLUMBING 2ND REVIEW**DENIED**
  
 1) BEING THAT THIS IS A CHANGE OF OCCUPANCY BOTH THE
 EXISTING RESTRROOMS SHALL COMPLY WITH 2017 FBC PLUMBING
 AND ACCESSIBILITY. THE RESTROOMS MUST FULLY COMPLY AND
 BE PART OF THE INSPECTIONS. FBC 107.3.5
  
 2) PROVIDE CLEAR FLOOR SPACE AND CABINET HEIGHT FOR 1
 OF THE 2 HAND SINKS. FBC-A 212.2, 606
  
 3) SHT P-1 CALLS OUT THE DRINKING FOUNTAIN IS EXISTING.
 PERMIT # 17060769 AND FINAL REVISION #18019865 DO NOT
 SHOW A DRINKING FOUNTAIN, PROVIDE CLEAR FLOOR SPACE AND
 MOUNTING HEIGHT DETAILS. FBC 107.3.5
  
 4) SHT P-1 LITE FILTER DOES NOT MEET THE INTENT OF THE
 CODE FBC-P 1003.1. PROVIDE A LIT INTERCEPTOR AND THE
 COMPLETE INSTALLATION MANUAL. FBC -P 1003.6.
  
 5) SHOW THE RELIEF LINE FOR THE WATER HEATER
 DISCHARGING INTO THE ROOM/ HEATER PAN. FBC-P 504.6.
 PROVIDE HOW THE PAN DRAIN IS GOING TO BE RAN OUTSIDE
 AND TERMINATE MIN 6" ABOVE GRADE. FBC-P 504.7, 504.7.1,
 504.7.2
  
 6) PLUMBING ISOMETRIC AND FLAT DRAWING DOERS NOT SHOW
 EITHER GROUP OF PEDICURE CHAIRS AS VENTED. PROVIDE
 ISOMETRIC AND FLAT DRAWING PROPERLY VENTED ALL FIXTURES
 FBC-P 901.2.1.
  
 7) PROVIDE PEDICURE CHARIS SPEC SHEETS AND INSTALLATION
 MANUAL'S. FBC 107.3.5
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-12-27 Cont ID  
Sent By gjohnson Date 2018-12-27 Time 08:53 Rev Time 0.00
Received By gjohnson Date 2018-12-27 Time 08:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-12-21 Cont ID  
Sent By jroach Date 2018-12-21 Time 11:09 Rev Time 0.00
Received By jroach Date 2018-12-21 Time 11:05 Sent To  
Notes
***NONE***