Plan Review Details - Permit 18110604
| Plan Review Stops For Permit 18110604 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-01-24 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-01-24 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2019-01-24 08:55:35 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | APPROVED WITH PROVISO: | | | | | | 1. PROVIDE A COMPLETED FORM BOARD SURVEY (INCLUDING | | | ELEVATIONS & WATER RUN-OFF/DRAINAGE INDICATORS) AND | | | ELEVATION CERTIFICATE AT TIME OF SLAB INSPECTION. | | | | | | 2. HAVE THE APPROVED ROOFING PERMIT ON-SITE PRIOR TO | | | BEGINNING ROOF WORK. | | | | | | NOTES: | | | | | | AT TIME OF INSPECTION, PLEASE PROVIDE THE FOLLOWING | | | INFORMATION FOR THE INSPECTOR. | | | | | | FBC R 314 AND 315 LISTED AND LABELED CARBON MONOXIDE | | | AND SMOKE DETECTORS ARE REQUIRED. | | | | | | AWS D1.1 CLAUSE 3.1 AND 4.15 AT TIME OF INSPECTION, FOR | | | THE STEEL COLUMN, PROVIDE A WELD PROCEDURE | | | SPECIFICATION; (SPECIFIES THE ESSENTIAL VARIABLES | | | INCLUDING: BASE MATERIALS, THE JOINTS, THE WELDING | | | PROCESS, AND THE FILLER METALS TO BE USED). | | | ALSO, PROVIDE THE WELDERS PERFORMANCE QUALIFICATION | | | RECORD; (SHOWS THE WELDER IS QUALIFIED & CERTIFIED FOR | | | THE DESCRIBED TYPE OF WELDING REQUIRED ON THIS | | | PROJECT). | | | | | | THE TRUSS ENGINEERING PACKAGE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-12-15 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-12-14 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2018-12-15 15:44:38 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | CORRECTIONS: | | | | | | FBC B 107.1 A ROOFING PERMIT IS REQUIRED. | | | FBC B 107.2.1 PLEASE PROVIDE MORE INFORMATION: | | | ON PAGE A-2, THE 16"X 16" COLUMN AT REAR PATIO DOES NOT | | | APPEAR. PLEASE PROVIDE THE COLUMN IN THE PROPOSED | | | LOCATION FOR CLARITY. | | | ON PAGE A-2, THE COMPONENT AND CLADDING PRESSURE | | | SCHEDULE SHOWS A 9'X 7' GARAGE DOOR. PLEASE PROVIDE THE | | | INTENDED LOCATION FOR THIS DOOR OR REMOVE FROM PLAN. | | | ON PAGE A-3, THE LOCATION/CONFIGURATION OF THE ATTIC | | | ACCESS OPENING IS RUNNING PERPINDICULAR TO THE PROPOSED | | | DIRECTION OF ROOF TRUSS. PLEASE RECONFIGURE OR | | | RELOCATE, | | | ON PAGE A-7 DETAILS A, B, D, AND WITHIN THE SUBMITTED | | | ENERGY AND LOAD CALCULATION SUBMITTALS, R-19 AND R-30 | | | INSULATION BATTS ARE INDICATED ABOVE THE CEILING. ON | | | PAGE A-3 NOTES AND IN A SEPERATE SUBMITTAL PACKAGE, | | | OPEN CELL SPRAY APPLIED ICENYNE INSULATION HAS BEEN | | | SUBMITTED. PLEASE | | | CLARIFY | | | ON PAGES A-1, A-2, AND A-3 THE WINDOW/DOOR SCHEDULE AND | | | OPENING INDICATORS ARE NOT COMPLETE AND DO NOT | | | COMPLETELY MATCH. | | | MISSING MECHANICAL PAGES. | | | FBC B 107.2.5 PROVIDE THE PROPOSED FINISHED FLOOR | | | ELEVATION AND EXTERIOR GRADE ELEVATIONS WITH DIRECTION | | | OF WATER DRAINAGE/RUN-OFF INDICATORS ON THE | | | SURVEY/SITE-PLAN. | | | | | | | | | NOTES: | | | | | | AT TIME OF INSPECTION, PLEASE PROVIDE THE FOLLOWING | | | INFORMATION FOR THE INSPECTOR. | | | | | | FBC R 314 AND 315 LISTED AND LABELED CARBON MONOXIDE | | | AND SMOKE DETECTORS ARE REQUIRED. | | | | | | AWS D1.1 CLAUSE 3.1 AND 4.15 AT TIME OF INSPECTION, FOR | | | THE STEEL COLUMN, PROVIDE A WELD PROCEDURE | | | SPECIFICATION; (SPECIFIES THE ESSENTIAL VARIABLES | | | INCLUDING: BASE MATERIALS, THE JOINTS, THE WELDING | | | PROCESS, AND THE FILLER METALS TO BE USED). | | | ALSO, PROVIDE THE WELDERS PERFORMANCE QUALIFICATION | | | RECORD; (SHOWS THE WELDER IS QUALIFIED & CERTIFIED FOR | | | THE DESCRIBED TYPE OF WELDING REQUIRED ON THIS | | | PROJECT). | | | | | | THE TRUSS ENGINEERING PACKAGE. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. WHEN RESUBMITTING, | | | IT IS HELPFUL TO PROVIDE A RESPONSE LETTER ADDRESSING | | | EACH ITEM ALONG WITH THE CITY RE-SUBMITTAL FORM. | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS | | | DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-06 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-05 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-05 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2019-02-05 13:16:15 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. AFCI PROTECTION SHOWN IN NOTE 24 IS NOT CODE | | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | 2. NOTE 25 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE PANEL INCLUDING INFORMATION FROM THE POWER | | | COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | | RATING OF THE SERVICE EQUIPMENT AND DOWNSTREAM PANELS | | | IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3 | | | 4. PROVIDE AIC RATING OF SERVICE PANEL. NEC 110.3, | | | 110.9; FBC RE E3603.3 | | | 5. SHOW LOCATION ON PLAN OF SERVICE AND MAIN PANEL. IF | | | DISTANCE IS GREATER THAN 8 FEET FROM METER TO MAIN | | | PANEL, PROVIDE DISCONNECT OR MAIN BREAKER ON EXTERIOR | | | OF RESIDENCE. IF THIS IS THE CASE, PROVIDE EQUIPMENT | | | GROUNDING CONDUCTOR TO INTERIOR PANEL. WPB FBC 107.2.1; | | | NEC 250.122; FBC RE E3704.6, 3607.3.1 | | | 6. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 | | | 7. - CORRECTED | | | 8. - CORRECTED | | | 9. NOTE PROVIDED - COMPLETED | | | 10. - CORRECTED | | | 11. - CORRECTED | | | 12. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 - NOT SHOWN | | | 13. - CORRECTED | | | 14. - CORRECTED | | | 15. - CORRECTED | | | 16. - CORRECTED | | | 17. - CORRECTED | | | | | | NEW COMMENTS: | | | | | | 1. - CORRECTED | | | | | | 2. FBC 107.2.1 ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5) AND F.S. 481.229. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-24 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2019-01-25 09:03:44 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. AFCI PROTECTION SHOWN IN NOTE 24 IS NOT CODE | | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | 2. NOTE 25 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE PANEL INCLUDING INFORMATION FROM THE POWER | | | COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | | RATING OF THE SERVICE EQUIPMENT AND DOWNSTREAM PANELS | | | IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3 | | | 4. PROVIDE AIC RATING OF SERVICE PANEL. NEC 110.3, | | | 110.9; FBC RE E3603.3 | | | 5. SHOW LOCATION ON PLAN OF SERVICE AND MAIN PANEL. IF | | | DISTANCE IS GREATER THAN 8 FEET FROM METER TO MAIN | | | PANEL, PROVIDE DISCONNECT OR MAIN BREAKER ON EXTERIOR | | | OF RESIDENCE. IF THIS IS THE CASE, PROVIDE EQUIPMENT | | | GROUNDING CONDUCTOR TO INTERIOR PANEL. WPB FBC 107.2.1; | | | NEC 250.122; FBC RE E3704.6, 3607.3.1 | | | 6. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 | | | 7. CONDUIT SIZE FOR FEED TO INTERIOR PANEL IS TOO SMALL | | | FOR THE REQUIRED CONDUCTORS. PROVIDE CORRECTION. NEC | | | TABLES; FBC RE TABLES E3904.6 - CORRECTED | | | 8. RISER DIAGRAM SHOWS 4/0 CONDUCTORS FOR A 300 AMP | | | SERVICE. THIS SIZE WIRE IS NOT RATED FOR 300 AMP | | | RESIDENTIAL SERVICE. PROVIDE CORRECTION. NEC | | | 310.15(B)(7) ; FBC RE E3603.1 - CORRECTED | | | 9. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 - | | | 10. PANEL SCHEDULE DOES NOT SHOW THE GFCI PROTECTED | | | RECEPTACLE ON A 20 AMP CIRCUIT REQUIRED FOR BATHROOM | | | RECEPTACLE OUTLETS. PROVIDE CORRECTION. NEC | | | 210.11(C)(3), 210.52(D); FBC RE E3703.4, E3901.6 | | | 11. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE, INCLUDING GARAGE DOOR OPENER. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 12. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 13. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 14. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. AC LOAD SHOULD NOT BE INCLUDED IN THE DEMAND | | | FACTORS. SEE FBC RE 3602. NEC 220; FBC RE E3602.2 | | | 15. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | | 410.10(D); FBC RE E4003.11 | | | 16. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS | | | LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY | | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE | | | CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 17. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC RE R315.1 | | | | | | NEW COMMENTS: | | | | | | 1. INCLUDE LAUNDRY ROOM ON PANEL SCHEDULE. | | | | | | 2. FBC 107.2.1 ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5) AND F.S. 481.229. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-04 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-04 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2018-12-04 17:51:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION SHOWN IN NOTE 24 IS NOT CODE | | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | | 2. NOTE 25 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE PANEL INCLUDING INFORMATION FROM THE POWER | | | COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | | RATING OF THE SERVICE EQUIPMENT AND DOWNSTREAM PANELS | | | IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3 | | | 4. PROVIDE AIC RATING OF SERVICE PANEL. NEC 110.3, | | | 110.9; FBC RE E3603.3 | | | 5. SHOW LOCATION ON PLAN OF SERVICE AND MAIN PANEL. IF | | | DISTANCE IS GREATER THAN 8 FEET FROM METER TO MAIN | | | PANEL, PROVIDE DISCONNECT OR MAIN BREAKER ON EXTERIOR | | | OF RESIDENCE. IF THIS IS THE CASE, PROVIDE EQUIPMENT | | | GROUNDING CONDUCTOR TO INTERIOR PANEL. WPB FBC 107.2.1; | | | NEC 250.122; FBC RE E3704.6, 3607.3.1 | | | 6. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 | | | 7. CONDUIT SIZE FOR FEED TO INTERIOR PANEL IS TOO SMALL | | | FOR THE REQUIRED CONDUCTORS. PROVIDE CORRECTION. NEC | | | TABLES; FBC RE TABLES E3904.6 | | | 8. RISER DIAGRAM SHOWS 4/0 CONDUCTORS FOR A 300 AMP | | | SERVICE. THIS SIZE WIRE IS NOT RATED FOR 300 AMP | | | RESIDENTIAL SERVICE. PROVIDE CORRECTION. NEC | | | 310.15(B)(7) ; FBC RE E3603.1 | | | 9. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 10. PANEL SCHEDULE DOES NOT SHOW THE GFCI PROTECTED | | | RECEPTACLE ON A 20 AMP CIRCUIT REQUIRED FOR BATHROOM | | | RECEPTACLE OUTLETS. PROVIDE CORRECTION. NEC | | | 210.11(C)(3), 210.52(D); FBC RE E3703.4, E3901.6 | | | 11. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE, INCLUDING GARAGE DOOR OPENER. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 12. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 13. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 14. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. AC LOAD SHOULD NOT BE INCLUDED IN THE DEMAND | | | FACTORS. SEE FBC RE 3602. NEC 220; FBC RE E3602.2 | | | 15. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | | 410.10(D); FBC RE E4003.11 | | | 16. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS | | | LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY | | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE | | | CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 17. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC RE R315.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-06 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2019-02-06 10:59:50 | PROVISO PROVIDED FOR GAS REVIEW. CT |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-05 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-05 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2019-02-05 11:39:22 | GAS PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING, (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1. | | | | | | 2. TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 3. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-RES. SEC. | | | G2413.3, G2413.4 AND TABLES G2413.4 (1 ) THROUGH | | | G2413.4 (21). CONTRACTOR TO STATE WHICH TABLES ARE | | | USED. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-RES. SEC. G 2413.4.1, G2413.4.2. | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-RES. SEC.G 2407.1 AND G2439.4 (CLOTHES DRYERS). | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 7. SUBMIT TWO COPIES OF A DETAIL SHOWING THE TYPE OF | | | VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER | | | 2017 FBC-RES. SEC.G2426 THROUGH G2439. | | | | | | 8. SUBMIT TWO COPIES OF THE MANUFACTURER?S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND | | | 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION. FBC-RES. SEC.G2408.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-25 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2019-01-25 09:02:28 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-05 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-30 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2019-01-31 14:57:49 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-11 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-01-03 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-11-14 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2018-11-21 10:15:32 | R11 | | 2018-11-15 15:01:53 | LIBRARY |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-06 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-06 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2019-02-06 09:26:11 | MU-2019-001308-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-05 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-05 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2019-02-05 13:14:41 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-01-04 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-01-04 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2019-01-04 08:00:58 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | IMPACT FEES - PAPER SUBMITTALS | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-24 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-03 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-12-03 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-12-03 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2018-12-03 09:34:40 | NEED MECHANICAL PLAN | | | | | | CHRIS MONTELLO | | | 805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-05 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-05 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-24 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2019-01-25 08:38:40 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. FBC 107.2.1 ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5) AND F.S. 481.229. | | | | | | 2. GAS PERMIT REQUIRED. PROVIDE GAS PLAN AND RISER | | | DIAGRAHM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-03 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-03 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2019-01-03 14:23:42 | CODES IN EFFECT | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: DENIED | | | PLUMBING COMMENTS | | | | | | 1.RE: PLAN SHEET A-9 | | | A. PLAN SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN PER WPB FBC 107.2.1 WHERE | | | REQUIRED BY CHAPTER 471, FLORIDA STATUTES & 61G15 | | | FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA | | | STATUTES & 61G1 FLORIDA ADMINISTRATIVE CODE | | | B. RISER DIAGRAM | | | 1) LAUNDRY SINK REQUIRES A VENT PER FBC RES P3105.1 | | | 2) CLOTHES WASHER REQUIRES A VENT PER FBC RES P3105.1 | | | IF AN AIR ADMITTANCE VALVE IS USED THEN THE UNDER FLOOR | | | HORIZONTAL PORTION OF THE FIXTURE DRAIN PIPING SHALL BE | | | A MINIMUM OF 3" IN ACCORDANCE WITH MANUFACTURER'S | | | RECOMMENDATION. | | | 3) FIXTURE BRANCH PIPING DOWNSTREAM OF THE CONNECTION | | | BETWEEN THE CLOTHES WASHER AND THE LAUNDRY SINK SHALL | | | BE A MINIMUM OF 3" PER FBC RES P2601.1 AND FBC PL | | | 406.2. | | | 4) IDENTIFY THE KITCHEN SINK ON THE RISER DIAGRAM PER | | | WPB FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-17 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-01-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-01-17 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-11-30 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-11-30 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2018-11-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-11-30 14:57:01 | *************************ZONING REVIEW | | | FAILED****************************** | | | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | THE PROPOSED DRIVEWAY, POOL, AND FENCE REQUIRES A | | | SEPARATE PERMIT. | | | | | | PROVIDE A SITE PLAN FOR HOUSE. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy