| 2018-12-11 11:33:58 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1) THERE IS NO OCCUPANCY TYPE INDICATED FOR THE REAR |
| | BUILDIING INDICATED ON THE SITE PALN. |
| | |
| | PLEASE PROVIDE THE OCCUPANCY TYPE PER THE FLORIDA FIRE |
| | PROTECTION CODE. |
| | |
| | |
| | |
| | 2) THERE ARE FIVE WINDOWS ON THE FRONT OF THE REAR |
| | BUILDING. HOW MANY FRAME CANOPIES ARE PROPOSED. |
| | |
| | PLEASE PROVIDE A HORIZONTAL VIEW SHOWING THE LOCATION |
| | OF THE PROPOSED. |
| | |
| | |
| | |
| | 3) THERE ARE NO INDICATION OF THE TYPE OF FRABIC OR ANY |
| | FLAME SPREAD RATING PER THE FFPC. |
| | |
| | 25.5.1.5 FLAME PROPAGATION PERFORMANCE. |
| | 25.5.1.5.1 ALL MEMBRANE STRUCTURE FABRIC SHALL MEET THE |
| | FLAME |
| | PROPAGATION PERFORMANCE CRITERIA CONTAINED IN TEST |
| | METHOD 2 OF |
| | NFPA 701, STANDARD METHODS OF FIRE TESTS FOR FLAME |
| | PROPAGATION OF TEXTILES AND FILMS. [101: 11.9.1.6.1] |
| | 25.5.1.5.2 ONE OF THE FOLLOWING SHALL SERVE AS EVIDENCE |
| | THAT THE |
| | FABRIC MATERIALS HAVE THE REQUIRED FLAME PROPAGATION |
| | PERFORMANCE: |
| | (1) THE AHJ SHALL REQUIRE A CERTIFICATE OR OTHER |
| | EVIDENCE OF |
| | ACCEPTANCE BY AN ORGANIZATION ACCEPTABLE TO THE AHJ. |
| | (2) THE AHJ SHALL REQUIRE A REPORT OF TESTS MADE BY |
| | OTHER |
| | INSPECTION AUTHORITIES OR ORGANIZATIONS ACCEPTABLE TO |
| | THE |
| | AHJ. [101: 11.9.1.6.2] |
| | 25.5.1.5.3 WHERE REQUIRED BY THE AHJ, CONFIRMATORY |
| | FIELD TESTS |
| | SHALL BE CONDUCTED USING TEST SPECIMENS FROM THE |
| | ORIGINAL |
| | MATERIAL, WHICH SHALL HAVE BEEN AFFIXED AT THE TIME OF |
| | MANUFACTURE |
| | TO THE EXTERIOR OF THE STRUCTURE. [101: 11.9.1.6.3] |
| | |
| | PLEASE PROVIDE THE APPLICABLE CERTIFICATION DOCUMENTS |
| | AND/OR ACTUAL MATERIAL SAMPLE FOR TESTING. |
| | |
| | |
| | |
| | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |
| | |
| | |
| | 5)ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |
| | |
| | |
| | |
| | |