| Plan Review Stops For Permit 18110491 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-12-28 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-12-28 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-12-04 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-12-04 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2018-12-04 14:57:12 | 1ST REVIEW: FBC 2017 6TH EDITION | | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | | | | BUILDING - FAILED | | | | | | FBC 107 PROVIDE CODE INFORMATION. ADD THE FOLLOWING TO | | | THE PLAN: | | | | | | FBC 2017 6TH EDITION | | | FBC 2017 EXISTING BUILDING | | | TYPE IIB CONSTRUCTION NON COMBUSTIBLE | | | OCCUPANCY CLASSIFICATION R-2 | | | LEVEL II ALTERATION | | | | | | PROVIDE A TYPICAL WALL SECTION OF WALLS TO BE ADDED IF | | | APPLICABLE. | | | | | | PROVIDE A FLOORING SUBMITTAL CONSISTING OF INSULATION | | | TEST REPORTS AND HARD FLOORING TYPE TO SHOW COMPLIANCE | | | WITH THE FOLLOWING: | | | | | | FBC 603.1 FLAME SPREAD; INSULATION BETWEEN A FINISHED | | | FLOOR AND SOLID DECKING W/O AN INTERVENING SPACE | | | W/FLAME SPREAD INDEX OF 200 OR LESS. | | | | | | FBC 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | | | | STEVEN KENNEDY, CBO | | | ASSISTANT BUILDING OFFICIAL | | | (561) 805-6710 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-01-14 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-01-14 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-12-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-20 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-20 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2018-12-04 13:24:31 | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | NO ELECTRIC SHOWN | | | | | | NARATIVE STATES : | | | | | | ADDING LIGHTS UNDER CABINETS, 8 HI HATS. | | | | | | RELOCATING BRANCH CIRCUITS AND OUTLETS | | | | | | PLEASE SHOW DETAIL ON PLANS OF PROPOSED ELECTRICAL | | | WORK. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-11-20 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-11-20 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-01-14 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-01-09 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2019-01-10 13:48:33 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-12-28 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-12-14 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2018-12-17 14:08:38 | RESUB ROUTED TO SKENNEDY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-12-04 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-11-13 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-12-28 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-12-28 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2018-12-28 10:04:02 | APPLICANT RESPONDED INDICATING THERE IS NO MECHANICAL | | | WORK TO BE PERFORMEDD. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-12-04 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-12-04 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2018-12-04 14:54:23 | 1ST REVIEW: FBC 2017 6TH EDITION | | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | | | | MECHANICAL - FAILED | | | | | | PROVIDE A MECHANICAL PLAN TO SHOW ALTERED DUCT WORK: | | | | | | | | | FBC -107.3.5.1.4 MECHANICAL MINIMUM PLAN REVIEW | | | CRITERIA: SHOW, DUCT SYSTEMS. | | | | | | | | | STEVEN KENNEDY, CBO | | | ASSISTANT BUILDING OFFICIAL | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-12-04 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-12-04 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2018-12-28 10:04:29 | FIXTURE REPLACEMENT ONLY. |
|
|